company logo Amprobe 33XR-A True RMS Digital Multimeter
     Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.  
 
 
 



Amprobe 33XR-A True RMS Digital Multimeter




Click image to enlarge

Amprobe 33XR-A

Features:
  • Min/Max, Relative, Peak and Data Hold
  • Auto power off to save battery life
  • Separate door for easy battery and fuse access
  • Magne-Grip™ Holster with magnetic hanging strap
  • Display: 3-3/4 digit LCD, 3999 counts with 41-segment analog bar graph
  • Display Update Rate: 2/sec, nominal
  • Analog bar graph
  • Overrange indication
  • Operating Temperature: 0 °C to 45 °C at < 70 % R.H.
  • Storage Temperature: -20 °C to 60 °C,
  • Input warning tone when test leads are in wrong jack



  Description

The 33XR-A is a manual ranging handheld digital multimeter used by field service technicians for measuring or testing the following:

  • DC and AC voltage
  • DC and AC current
  • Resistance
  • Frequency
  • Temperature
  • Capacitance
  • Diodes
  • Continuity
Additional testing features include the following modes: MIN MAX, HOLD, REL (relative), and Peak±.



  Models, Options, & Accessories

  • Test leads w/ alligator clips 1 set
  • Holster 1
  • Magnet Strap 1
  • Temperature Adapter 1
  • K-type thermocouple 1
  • User Manual
  • 9 V battery (installed) 1
  • mA fuse, 0.315 A/ 1000 V 1 spare


Model Description List Price Sale Price
33XR-A PROF DMM W TEMP AND CAPACITANCE $79.95
$69.56 



  Specifications

General Specifications
Display 3 ¾ digit liquid crystal display (LCD)(3999 count) with a 41-segment analog bar-graph.
Polarity Automatic, positive implied, negative polarity indication.
Overrange (o) or (-o) is displayed.
Zero Automatic.
Low battery indication The B is displayed when the battery voltage drops below the operating level.
Auto power off Approximately 30 minutes.
Measurement rate 2 times per second, nominal.
Operating environment 0 °C to 50 °C at <70 % R.H.
Storage temperature -20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter.
Temperature Coefficient 0.1 ¡¿ (specified accuracy) per °C.
(0 °C to 18 °C, 28 °C to 50 °C).
Environment Indoor use, altitude up to 2000 m
Power Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22.
Battery life 150 hours typical with carbon-zinc.
300 hours typical with alkaline.
Dimensions 196 mm (H) x 92 mm (W) x 60 mm (D).
Weight Approximately 400 g including battery.
Warranty One-Year
Battery Life 300 hrs typical (alkaline)
Size 7.7" x 3.5" x 2.3" (196 x 92 x 60 mm)
Safety Cat II 1000V, Cat III 600V
Electrical Specifications
DC Voltage Ranges 400 mV, 4 V, 40 V, 400 V, 1000 V
DC Voltage Accuracy all ranges: ± (0.7 % rdg + 1 dgt)
DC Voltage Resolution 100 µV
DC Voltage Input Impedance 10 Mω
AC Voltage (45 Hz to 500 Hz) Ranges 400 mV, 4 V, 40 V, 400 V, 750 V
AC Voltage (45 Hz to 500 Hz) Accuracy 4 V Range, 200 Hz to 500 Hz: ± (2.0 % rdg + 4 dgts)
AC Voltage (45 Hz to 500 Hz) Accuracy All other ranges: ± (1.5 % rdg + 4 dgts)
AC Voltage (45 Hz to 500 Hz) Resolution 100 µV
AC Voltage (45 Hz to 500 Hz) Input Impedance 10 Mω
DC Current Ranges 400 µA, 4 mA, 40 mA, 300 mA, 10 A
DC Current Accuracy 400 µA to 300 mA ranges: ± (1.0 % rdg + 1 dgt)
DC Current Accuracy 10 A range: ± (2.0 % rdg + 3 dgts)
DC Current Resolution 0.1 µA
DC Current Voltage Burden 400 µA range: 1 mV/µA, 4 mA range: 100 mV/1 mA, 40 mA range: 12 mV/1 mA,
DC Current Voltage Burden 300 mA range: 4 mV/1 mA, 10 A range: 100 mV/1 A
AC Current (45 Hz to 500 Hz) Ranges 400 µA, 4 mA, 40 mA, 300 mA, 10 A
AC Current (45 Hz to 500 Hz) Accuracy 400 µA to 300 mA ranges: ± (1.5 % rdg + 4 dgts)
AC Current (45 Hz to 500 Hz) Accuracy 10 A range: ± (2.5 % rdg + 4 dgts) AC Current (45 Hz to 500 Hz) Resolution: 0.1 µA
AC Current (45 Hz to 500 Hz) Voltage Burden See DC Current
Resistance Ranges 400 ω 40 kω 4 Mω
Resistance Accuracy 400 ωand 40 kω ranges: ± (1.0 % rdg + 4 dgts)
Resistance Accuracy 4 Mω range: ± (1.2 % rdg + 4 dgts)
Resistance Resolution 100 mω
Resistance Open Circuit Voltage 400 ω range: 3.0 V dc, All other ranges: 0.5 V dc typical
Frequency (autoranging)
Ranges 4 kHz, 40 kHz, 400 kHz, 4 MHz, 40 MHz
Accuracy all ranges: ± (0.1 % rdg + 3 dgts)
Resolution 1 Hz
Sensitivity 10 Hz to 4 MHz: > 1.5 V ac rms
4 MHz to 40 MHz: > 2 V ac rms, < 5 V ac rms
Min Pulse Width > 25 ns
Duty Cycle Limits > 30 % and < 70 %
Continuity
Audible Indication < 35 ω
Response Time 100 ms
Diode Test
Test Current 1.0 mA (approximate)
Accuracy ± (1.5 % rdg + 3 dgts)
Resolution 1 mV
Open Circuit Volts 3.0 V dc typical
Peak Hold
AC Volts Accuracy 40 V to 750 V: ± (3.0 % rdg + 60 dgts)
AC Current Accuracy ± (3.0 % rdg + 60 dgts)
Response Time > 1 ms
Overload Protection
AC/DC Voltage 400 mV range: 1000 V dc or 750 V ac rms 15 sec
All other ranges: 1000 V dc or 750 V ac rms
AC/DC Current uA/mA input: 0.315 A /1000 V fast-blow ceramic (6.3 x 32 mm)
10 A input: 10 A /1000 V fast-blow ceramic (10 x 38 mm)
(10 A for 4 minutes maximum followed by a 12 minute cooling period)
Resistance 1000 V dc or 750 V ac rms
Continuity 1000 V dc or 750 V ac rms
Diode Test 1000 V dc or 750 V ac rms
Capacitance 0.315 A /1000 V fast-blow ceramic (6.3 x 32 mm)
Temperature 1000 V dc or 750 V ac rms
Frequency 1000 V dc or 750 V ac rms




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 



Live chat by BoldChat
Need help? We have a staff
of more than 30 people to help you.
Let us show you why over 100,000
customers choose Tequipment.NET