company logo Amprobe 34XR-A True RMS Digital Multimeter
     Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.  
 
 
 



Amprobe 34XR-A True RMS Digital Multimeter




Click image to enlarge

Amprobe 34XR-A

Features:
  • Autoranging; Display: 3-3/4 digit LCD, 3999 counts with 41-segment analog bar graph
  • Display Update Rate: 2/sec, nominal
  • Operating Temperature: 0 °C to 45 °C at < 70 % R.H
  • True RMS digital multimeter with temperature and backlight
  • Overrange indication
  • Auto power off to save battery life
  • Min/Max, Data Hold and Range Lock
  • Separate door for easy battery and fuse access
  • Magne-Grip™ Holster with magnetic hanging strap



  Description

The Amprobe 34XR-A is a true RMS digital multimeter with temperature and backlight, providing contractors and field service technicians with high quality and unmatched reliability.



  Models, Options, & Accessories

   Includes:

  • Test leads w/ alligator clips 1 set
  • Holster 1
  • Magnet Strap 1
  • Temperature Adapter 1
  • K-type thermocouple 1
  • User Manual
  • 9 V battery (installed) 1
  • mA fuse, 0.315 A/ 1000 V 1 spare


Model Description List Price Sale Price
34XR-A PROF DMM TRUE RMS W TEMPERATURE & BACKLIGHT $119.94
$104.35 
Model Accessories List Price Sale Price
VC221B VINYL CARRYING CASE, FULL SIZE METERS $16.95
$14.75 
DL248D DELUXE TEST LEAD KIT $57.95
$50.42 
DC205C DELUXE HARD SHELL CASE $39.95
$34.76 
HV231-10A HV PROBE 10 MEGOHM $104.95
$91.31 
TP254A IMMERSION TEMPERATURE PROBE $58.95
$51.29 



  Specifications

General Specifications
Display 3 ¾ digit liquid crystal display (LCD)(3999 count) with a 41-segment analog bar-graph.
Polarity Automatic, positive implied, negative polarity indication. Overrange = (0o) or (-0o) is displayed.
Zero Automatic.
Low battery indication The B is displayed when the battery voltage drops below the operating level.
Auto power off Approx. 30 minutes.
Measurement rate 2 times per second, nominal.
Operating environment 0 º to 50 º at <70 % R.H.
Storage temperature -20 º to 60 º, 0 to 80 % R.H. with battery removed from meter.
Temperature Coefficient 0.1 x (specified accuracy) per º. (0 º to 18 º, 28 º to 50 º).
Altitude 2000 m (6562 feet)
Power Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22.
Battery life 100 hours typical with carbon-zinc. 200 hours typical with alkaline. Frequent use of the backlight will decrease battery life.
Dimensions 196 mm (H) x 92 mm (W) x 60 mm (D).
Weight Approximately 400 g including battery.
Warranty One-Year.
Electrical Specifications
DC Voltage Ranges 400 mV, 4 V, 40 V, 400 V, 1000 V
DC Voltage Accuracy all ranges: ± (0.5 % rdg + 1 dgt)
DC Voltage Resolution 100 µV
AC Voltage (45 Hz to 2 kHz) True RMS Ranges 400 mV, 4 V, 40 V, 400 V, 750 V
AC Voltage (45 Hz to 2 kHz) True RMS Accuracy 400 mV range, 45 to 100 Hz: ± (1.2 % rdg + 8 dgts)
AC Voltage (45 Hz to 2 kHz) True RMS Accuracy 750 V range: 45 to 1 kHz: ± (2.0 % rdg + 8 dgts)
AC Voltage (45 Hz to 2 kHz) True RMS Accuracy All other ranges, 45 to 500 Hz: ± (1.2 % rdg + 8 dgts)
AC Voltage (45 Hz to 2 kHz) True RMS Accuracy All other ranges, 500 to 2 kHz: ± (2.0 % rdg + 8 dgts)
AC Voltage (45 Hz to 2 kHz) True RMS Resolution 100 µV
DC Current Ranges 400 µA, 4 mA, 40 mA, 300 mA, 10 A
DC Current Accuracy 400 µA to 300 mA ranges: ± (1.0 % rdg + 1 dgt)
DC Current Accuracy 10 A range: ± (2.0 % rdg + 3 dgts)
DC Current Resolution 0.1 µA
DC Current Voltage Burden 400 µA range: 1 mV/µA, 4 mA range: 100 mV/1 mA, 40 mA range: 12 mV/1 mA,
DC Current Voltage Burden 400 µA, 4 mA, 40 mA, 300 mA, 10 A
AC Current (45 Hz to 1 kHz) True RMS Ranges 400 µA, 4 mA, 40 mA, 300 mA, 10 A
AC Current (45 Hz to 1 kHz) True RMS Accuracy 400 µA to 300 mA ranges: ± (1.5 % rdg + 8 dgts)
AC Current (45 Hz to 1 kHz) True RMS Accuracy 10 A range: ± (2.5 % rdg + 10 dgts)
AC Current (45 Hz to 1 kHz) True RMS Resolution 0.1 µA
Resistance Ranges 400 ω 4 kω 40 kω 400 kω 4 Mω 40 Mω
Resistance Accuracy 400, 4 k, 40 k, 400 k, 4 Mω ranges: ± (1.0 % rdg + 4 dgts)
Resistance Accuracy 40 Mω range: ± (2.0 % rdg + 5 dgts)
Resistance Resolution 100 mω
Continuity Audible Indication < 35 ω
Temperature
Ranges -20 °C to 1000 °C, -4 °F to 1832 °F
Accuracy -20 °C to 10 °C: ± (2.0 % rdg + 4 °C )
10 °C to 200 °C: ± (1.0 % rdg + 3 °C )
200 °C to 1000 °C: ± (3.0 % rdg + 2 °C )
-4 °F to 50 °F: ± (2.0 % rdg + 8 °F)
50 °F to 400 °F: ± (1.0 % rdg + 6 °F)
400 °F to 1832 °F: ± (3.0 % rdg + 4 °F)
Resolution 1 °C, 1 °F
Frequency
Ranges 4 kHz, 40 kHz, 400 kHz, 4 MHz, 40MHz
Accuracy all ranges: ± (0.1 % rdg + 3 dgts)
Resolution 1 Hz
Duty Cycle
Ranges 0 to 90 %
Accuracy 5 V logic: ± (2.0 % rdg + 5 dgts)
Frequency Range 40 Hz to 20 kHz
Continuity
Audible Indication < 35 ω
Diode Test
Test Current 1.2 mA (approximate)
Open Circuit Volts 3.0 V dc typical
Overload Protection
AC/DC Voltage All ranges 1000 V dc or 750 V ac rms
AC/DC Current µA/mA input: 0.315 A /1000 V fast-blow ceramic (6.3 x 32 mm)
10 A input: 10 A /1000 V fast-blow ceramic 10 x 38 mm
(10 A for 4 minutes maximum followed by a 12 minute cooling period)




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 




Fluke Sponsored March Madness Bracket Challenge

Quote Request

We Take POs, How To Order

Free Shipping on Select Premier Lines










Live chat by BoldChat
Let our engineers and cs staff help!
Need a quote? Need to check stock?
Have a technical question? No problem.
We are here to help.