| General Specifications |
| Display |
3 ¾ digit liquid crystal display (LCD)(3999 count) with a 41-segment analog bar-graph. |
| Polarity |
Automatic, positive implied, negative polarity indication. Overrange = (0o) or (-0o) is displayed. |
| Zero |
Automatic. |
| Low battery indication |
The B is displayed when the battery voltage drops below the operating level. |
| Auto power off |
Approx. 30 minutes. |
| Measurement rate |
2 times per second, nominal. |
| Operating environment |
0 º to 50 º at <70 % R.H. |
| Storage temperature |
-20 º to 60 º, 0 to 80 % R.H. with battery removed from meter. |
| Temperature Coefficient |
0.1 x (specified accuracy) per º. (0 º to 18 º, 28 º to 50 º). |
| Altitude |
2000 m (6562 feet) |
| Power |
Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22. |
| Battery life |
100 hours typical with carbon-zinc. 200 hours typical with alkaline. Frequent use of the backlight will decrease battery life. |
| Dimensions |
196 mm (H) x 92 mm (W) x 60 mm (D). |
| Weight |
Approximately 400 g including battery. |
| Warranty |
One-Year. |
| Electrical Specifications |
| DC Voltage Ranges |
400 mV, 4 V, 40 V, 400 V, 1000 V |
| DC Voltage Accuracy |
all ranges: ± (0.5 % rdg + 1 dgt) |
| DC Voltage Resolution |
100 µV |
| AC Voltage (45 Hz to 2 kHz) True RMS Ranges |
400 mV, 4 V, 40 V, 400 V, 750 V |
| AC Voltage (45 Hz to 2 kHz) True RMS Accuracy |
400 mV range, 45 to 100 Hz: ± (1.2 % rdg + 8 dgts) |
| AC Voltage (45 Hz to 2 kHz) True RMS Accuracy |
750 V range: 45 to 1 kHz: ± (2.0 % rdg + 8 dgts) |
| AC Voltage (45 Hz to 2 kHz) True RMS Accuracy |
All other ranges, 45 to 500 Hz: ± (1.2 % rdg + 8 dgts) |
| AC Voltage (45 Hz to 2 kHz) True RMS Accuracy |
All other ranges, 500 to 2 kHz: ± (2.0 % rdg + 8 dgts) |
| AC Voltage (45 Hz to 2 kHz) True RMS Resolution |
100 µV |
| DC Current Ranges |
400 µA, 4 mA, 40 mA, 300 mA, 10 A |
| DC Current Accuracy |
400 µA to 300 mA ranges: ± (1.0 % rdg + 1 dgt) |
| DC Current Accuracy |
10 A range: ± (2.0 % rdg + 3 dgts) |
| DC Current Resolution |
0.1 µA |
| DC Current Voltage Burden |
400 µA range: 1 mV/µA, 4 mA range: 100 mV/1 mA, 40 mA range: 12 mV/1 mA, |
| DC Current Voltage Burden |
400 µA, 4 mA, 40 mA, 300 mA, 10 A |
| AC Current (45 Hz to 1 kHz) True RMS Ranges |
400 µA, 4 mA, 40 mA, 300 mA, 10 A |
| AC Current (45 Hz to 1 kHz) True RMS Accuracy |
400 µA to 300 mA ranges: ± (1.5 % rdg + 8 dgts) |
| AC Current (45 Hz to 1 kHz) True RMS Accuracy |
10 A range: ± (2.5 % rdg + 10 dgts) |
| AC Current (45 Hz to 1 kHz) True RMS Resolution |
0.1 µA |
| Resistance Ranges |
400 ω 4 kω 40 kω 400 kω 4 Mω 40 Mω |
| Resistance Accuracy |
400, 4 k, 40 k, 400 k, 4 Mω ranges: ± (1.0 % rdg + 4 dgts) |
| Resistance Accuracy |
40 Mω range: ± (2.0 % rdg + 5 dgts) |
| Resistance Resolution |
100 mω |
| Continuity Audible Indication |
< 35 ω |
| Temperature |
| Ranges |
-20 °C to 1000 °C, -4 °F to 1832 °F |
| Accuracy |
-20 °C to 10 °C: ± (2.0 % rdg + 4 °C ) 10 °C to 200 °C: ± (1.0 % rdg + 3 °C ) 200 °C to 1000 °C: ± (3.0 % rdg + 2 °C ) -4 °F to 50 °F: ± (2.0 % rdg + 8 °F) 50 °F to 400 °F: ± (1.0 % rdg + 6 °F) 400 °F to 1832 °F: ± (3.0 % rdg + 4 °F) |
| Resolution |
1 °C, 1 °F |
| Frequency |
| Ranges |
4 kHz, 40 kHz, 400 kHz, 4 MHz, 40MHz |
| Accuracy |
all ranges: ± (0.1 % rdg + 3 dgts) |
| Resolution |
1 Hz |
| Duty Cycle |
| Ranges |
0 to 90 % |
| Accuracy |
5 V logic: ± (2.0 % rdg + 5 dgts) |
| Frequency |
Range 40 Hz to 20 kHz |
| Continuity |
| Audible Indication |
< 35 ω |
| Diode Test |
| Test Current |
1.2 mA (approximate) |
| Open Circuit |
Volts 3.0 V dc typical |
| Overload Protection |
| AC/DC Voltage |
All ranges 1000 V dc or 750 V ac rms |
| AC/DC Current |
µA/mA input: 0.315 A /1000 V fast-blow ceramic (6.3 x 32 mm) 10 A input: 10 A /1000 V fast-blow ceramic 10 x 38 mm (10 A for 4 minutes maximum followed by a 12 minute cooling period) |