company logo Amprobe 34XR-A True RMS Digital Multimeter
     Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.  
 
 
 



Amprobe 34XR-A True RMS Digital Multimeter




Click image to enlarge

Amprobe 34XR-A

Features:
  • Autoranging; Display: 3-3/4 digit LCD, 3999 counts with 41-segment analog bar graph
  • Display Update Rate: 2/sec, nominal
  • Operating Temperature: 0 °C to 45 °C at < 70 % R.H
  • True RMS digital multimeter with temperature and backlight
  • Overrange indication
  • Auto power off to save battery life
  • Min/Max, Data Hold and Range Lock
  • Separate door for easy battery and fuse access
  • Magne-Grip™ Holster with magnetic hanging strap



  Description

The Amprobe 34XR-A is a true RMS digital multimeter with temperature and backlight, providing contractors and field service technicians with high quality and unmatched reliability.



  Models, Options, & Accessories

   Includes:

  • Test leads w/ alligator clips 1 set
  • Holster 1
  • Magnet Strap 1
  • Temperature Adapter 1
  • K-type thermocouple 1
  • User Manual
  • 9 V battery (installed) 1
  • mA fuse, 0.315 A/ 1000 V 1 spare


Model Description List Price Sale Price
34XR-A PROF DMM TRUE RMS W TEMPERATURE & BACKLIGHT $99.95
$86.96 
Model Accessories List Price Sale Price
VC221B VINYL CARRYING CASE, FULL SIZE METERS $16.95
$14.75 
DL248D DELUXE TEST LEAD KIT $57.95
$50.42 
DC205C DELUXE HARD SHELL CASE $39.95
$34.76 
HV231-10A HV PROBE 10 MEGOHM $104.95
$91.31 
TP254A IMMERSION TEMPERATURE PROBE $58.95
$51.29 



  Specifications

General Specifications
Display 3 ¾ digit liquid crystal display (LCD)(3999 count) with a 41-segment analog bar-graph.
Polarity Automatic, positive implied, negative polarity indication. Overrange = (0o) or (-0o) is displayed.
Zero Automatic.
Low battery indication The B is displayed when the battery voltage drops below the operating level.
Auto power off Approx. 30 minutes.
Measurement rate 2 times per second, nominal.
Operating environment 0 º to 50 º at <70 % R.H.
Storage temperature -20 º to 60 º, 0 to 80 % R.H. with battery removed from meter.
Temperature Coefficient 0.1 x (specified accuracy) per º. (0 º to 18 º, 28 º to 50 º).
Altitude 2000 m (6562 feet)
Power Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22.
Battery life 100 hours typical with carbon-zinc. 200 hours typical with alkaline. Frequent use of the backlight will decrease battery life.
Dimensions 196 mm (H) x 92 mm (W) x 60 mm (D).
Weight Approximately 400 g including battery.
Warranty One-Year.
Electrical Specifications
DC Voltage Ranges 400 mV, 4 V, 40 V, 400 V, 1000 V
DC Voltage Accuracy all ranges: ± (0.5 % rdg + 1 dgt)
DC Voltage Resolution 100 µV
AC Voltage (45 Hz to 2 kHz) True RMS Ranges 400 mV, 4 V, 40 V, 400 V, 750 V
AC Voltage (45 Hz to 2 kHz) True RMS Accuracy 400 mV range, 45 to 100 Hz: ± (1.2 % rdg + 8 dgts)
AC Voltage (45 Hz to 2 kHz) True RMS Accuracy 750 V range: 45 to 1 kHz: ± (2.0 % rdg + 8 dgts)
AC Voltage (45 Hz to 2 kHz) True RMS Accuracy All other ranges, 45 to 500 Hz: ± (1.2 % rdg + 8 dgts)
AC Voltage (45 Hz to 2 kHz) True RMS Accuracy All other ranges, 500 to 2 kHz: ± (2.0 % rdg + 8 dgts)
AC Voltage (45 Hz to 2 kHz) True RMS Resolution 100 µV
DC Current Ranges 400 µA, 4 mA, 40 mA, 300 mA, 10 A
DC Current Accuracy 400 µA to 300 mA ranges: ± (1.0 % rdg + 1 dgt)
DC Current Accuracy 10 A range: ± (2.0 % rdg + 3 dgts)
DC Current Resolution 0.1 µA
DC Current Voltage Burden 400 µA range: 1 mV/µA, 4 mA range: 100 mV/1 mA, 40 mA range: 12 mV/1 mA,
DC Current Voltage Burden 400 µA, 4 mA, 40 mA, 300 mA, 10 A
AC Current (45 Hz to 1 kHz) True RMS Ranges 400 µA, 4 mA, 40 mA, 300 mA, 10 A
AC Current (45 Hz to 1 kHz) True RMS Accuracy 400 µA to 300 mA ranges: ± (1.5 % rdg + 8 dgts)
AC Current (45 Hz to 1 kHz) True RMS Accuracy 10 A range: ± (2.5 % rdg + 10 dgts)
AC Current (45 Hz to 1 kHz) True RMS Resolution 0.1 µA
Resistance Ranges 400 ω 4 kω 40 kω 400 kω 4 Mω 40 Mω
Resistance Accuracy 400, 4 k, 40 k, 400 k, 4 Mω ranges: ± (1.0 % rdg + 4 dgts)
Resistance Accuracy 40 Mω range: ± (2.0 % rdg + 5 dgts)
Resistance Resolution 100 mω
Continuity Audible Indication < 35 ω
Temperature
Ranges -20 °C to 1000 °C, -4 °F to 1832 °F
Accuracy -20 °C to 10 °C: ± (2.0 % rdg + 4 °C )
10 °C to 200 °C: ± (1.0 % rdg + 3 °C )
200 °C to 1000 °C: ± (3.0 % rdg + 2 °C )
-4 °F to 50 °F: ± (2.0 % rdg + 8 °F)
50 °F to 400 °F: ± (1.0 % rdg + 6 °F)
400 °F to 1832 °F: ± (3.0 % rdg + 4 °F)
Resolution 1 °C, 1 °F
Frequency
Ranges 4 kHz, 40 kHz, 400 kHz, 4 MHz, 40MHz
Accuracy all ranges: ± (0.1 % rdg + 3 dgts)
Resolution 1 Hz
Duty Cycle
Ranges 0 to 90 %
Accuracy 5 V logic: ± (2.0 % rdg + 5 dgts)
Frequency Range 40 Hz to 20 kHz
Continuity
Audible Indication < 35 ω
Diode Test
Test Current 1.2 mA (approximate)
Open Circuit Volts 3.0 V dc typical
Overload Protection
AC/DC Voltage All ranges 1000 V dc or 750 V ac rms
AC/DC Current µA/mA input: 0.315 A /1000 V fast-blow ceramic (6.3 x 32 mm)
10 A input: 10 A /1000 V fast-blow ceramic 10 x 38 mm
(10 A for 4 minutes maximum followed by a 12 minute cooling period)




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 



Live chat by BoldChat
Need help? We have a staff
of more than 30 people to help you.
Let us show you why over 100,000
customers choose Tequipment.NET