Rigol DS1104Z Plus 100 MHz Digital Oscilloscope with 4 Channels and 16 Digital Channels

 
Free In Person Demo
Rigol DS1104Z Plus
Catalog #: DS1104Z Plus
         
0 reviews
100 MHz Digital Oscilloscope with 4 channels, 12 Mpts memory (upgradeable to 24 Mpts), 1 GSa/sec sampling and Digital Logic Connector for optional MSO upgrade

Listen to Expert Highlights

Features

  • 4 Channels, 100 MHz Bandwidth and 16 digital channels
  • Digital Logic Connector for optional MSO upgrade: RPL1116
  • UltraVision: Deeper memory(Standard 12 Mpts, Upgradeable to 24 Mpts)
  • UltraVision: Up to 30,000 wfms/s Waveform capture rate
  • UltraVision: Multi-Level intensity grading display
  • UltraVision: Realtime waveform record, Replay, function (Opt.)
  • A variety of Math Functions
  • FFT function
  • A variety of Trigger Functions
  • Optional Serial Bus Triggering and Decoding functions(RS232, I2C, SPI)
  • Standard Mask test function
  • Automatic Measurements with Statistics
Loading Prices
Loading Callouts
Questions?
Ask Our Factory
Trained Engineers
M-F 8AM - 9PM EST
• 877.571.7901

Compare Products in this Series

Product Name Bandwidth Channels Sampling Rate Availability Price
DS1104Z Plus
DS1104Z Plus
100 MHz Digital Oscilloscope with 4 channels, 12 Mpts memory...
100 Mhz 4 1 GS/S
DS1074Z-S
DS1074Z-S
70 MHz Digital Oscilloscope with 4 channels and 25 MHz 2 channel...
70 Mhz 4 1 GS/S
DS1104Z-S
DS1104Z-S
100 MHz Digital Oscilloscope with 4 channels and 25 MHz 2 channel...
100 Mhz 4 1 GS/S
DS1074Z
DS1074Z
70 MHz Digital Oscilloscope with 4 channels plus 12 Mpt memory and 1...
70 Mhz 4 1 GS/S
DS1104Z
DS1104Z
100 MHz Digital Oscilloscope with 4 channels plus 12 Mpt memory and 1...
100 Mhz 4 1 GS/S
DS1054Z
DS1054Z
50 MHz Digital Oscilloscope with 4 channels plus 12 Mpt memory, 1 GS/s...
50 Mhz 4 1 GS/S
DS1054Z Kit1
DS1054Z Kit1
50 MHz Digital Oscilloscope with 4 ch, 12 Mpt memory, 1 GSa/sec...
50 Mhz 4 1 GS/S
DS1054z Kit2
DS1054z Kit2
50 MHz Digital Oscilloscope with 4 ch, 12 Mpt memory, 1 GSa/sec...
50 Mhz 4 1 GS/S
DS1074Z Plus
DS1074Z Plus
70 MHz Digital Oscilloscope with 4 channels plus 12 Mpt memory (24 Mpt...
70 Mhz 4 1 GS/S
DS1074Z-S Plus
DS1074Z-S Plus
70 MHz Digital Oscilloscope with 4 Channels and 16 Digital Channels +...
70 Mhz 4 1 GS/S
DS1104Z-S Plus
DS1104Z-S Plus
100 MHz Digital Oscilloscope with 4 Channels, 25 MHz 2 channel Signal...
100 Mhz 4 1 GS/S
DS1054Z Kit3
DS1054Z Kit3
Rigol DS1054Z 50 MHz Oscilloscope + Extech EX330 Multimeter + Hakko...
DS1054Z Kit4
DS1054Z Kit4
Rigol DS1054Z 50 MHz Oscilloscope + Rigol DP832 Power Supply + Extech...
DS1054Z Kit5
DS1054Z Kit5
Rigol DS1054Z 50 MHz Oscilloscope + Extech EX330 Multimeter + Hakko...
Rigol DS1104Z 100 MHz Digital Oscilloscope

Rigol DS1104Z Plus 100 MHz Digital Oscilloscope with 4 Channels and 16 Digital Channels

         
0 reviews
  Add to cart

Product Information

Rigol DS1104Z Plus 100 MHz Digital Oscilloscope

 
 
 

Best Selling Oscilloscope

The DS1104Z Plus is a high quality 4 channel 100 MHz oscilloscope with a 1G Sa/s real time sampling rate. This scope also includes a 7” WVGA intensity graded color display for easy viewing. The DS1104Z Plus features an easily accessible source control button and 4 easy to access analog channel ports. With an industry leading 12 Mpts memory (upgradeable to 24 Mpts) and a waveform capture rate of up to 30,000 wfms/s, the DS1104Z Plus is a great solution for nearly any application.

*Image shown is with Optional MSO Add-on Kit: RPL1116

DS1104Z Plus Features

  • 100 MHz Analog Bandwidth
  • Total of 4 Analog Channels
  • 1G Sa/s Real-time Sample Rate
  • Expandable to 16 total digital channels with optional upgrade
  • Maximum Waveform Capture Rate of up to 30,000 wfms/s
  • Includes 4 RP2200 150 MHz Passive HighZ Probes
  • Low noise floor
  • USB Host for Thumb Drive
  • Large 7" Display
  • 12 Mpts of Memory - upgradeable to 24
 
 

What makes the "Plus" so special?

The new Rigol DS1104Z Plus now features a digital logic connection next to the USB port. Simply by purchasing the MSO Upgrade Package, users will now have the equivalent of Rigol's MSO scopes. This connection allows users to unlock an additional 16 digital channels on their oscilloscope.

DS1000Z Plus Layout

UltraVision

Rigol's innovative UltraVision technology provides a deeper memory depth of 12Mpts standard and is upgradeable to 24 Mpts (with purchase of MEM-DS1000Z). The DS1104Z Plus also provides the ability to quickly focus in on certain piece of a recorded waveform.

UltraVision

×

Full Visibility

×

Full Visibility

The large 7" display of the DS1104Z Plus, with a resolution of 800 X 480 pixels makes it possible to view all channels on a single screen. This makes for better usability and more efficient analysis.

Ultra-fast Sampling Rate

Rigol has given the DS1000z series the ability to capture up to 30,000 waveform per second. This coupled with the 12 Mpts of memory and sampling rate of 1 GS/s makes this a great oscilloscope for nearly any application.

Ultra-fast Sampling Rate

×

Optional Waveform Recording

×

Optional Waveform Recording

Rigol has made recording waveforms an accessible option for all users with the simple purchase of the DS1000Z-REC software option. This allows users to go back and analyze previous data.

Multi-Level Intensity Graded Display

This feature provides users the ability to focus in and visually detect event frequency over time.

Multi-Level Intensity Graded Display

×

Advanced Triggering Options

×

Advanced Triggering Options

Adding to the flexibility of the DS1000Z line up, Rigol has added the option to purchase and advance triggering feature. This includes triggering options such RS232/URAT, I2C, SPI, Runt, Windows, Nth Edge, Delay, Time Out. This option can be purchased under product number AT-DS1000Z.

Serial Bus Analysis Options

By purchasing the SA-DS1000Z Serial Bus Analysis Option, users can examine, decode and view RS232/URAT, I2C, SPI.

Serial Bus Analysis Options

×

Advanced Signal Calculations

×

Advanced Signal Calculations

Rigol has integrated an advanced system of formulas designed to resolve complex signal calculations.

Mask Test Function

This test function allows user to test a signal on a pass or fail basis allowing for easy troubleshooting in many applications.

Mask Test Function

×

Automatic Measurement Parameters

×

Automatic Measurement Parameters

The DS1000Z series of oscilloscopes is capable of automatically measuring and recording within 5 set parameters. It will also produce a statistical analysis of each set parameter.

What's In The Box

  • Power Cord
  • USB Data Cable
  • 4 Passive Probes (150 MHz) RP2200
  • Quick Guide
  • Resource CD (User’s Guide and Application Software)

Specifications

General Specifications
Model DS1074Z Plus
DS1074Z-S Plus
DS1104Z Plus
DS1104Z-S Plus
Bandwidth 70MHz 100MHz
Channels 4
Maximum Sample Rate 1GSa/s (1Ch), 500MSa/s (2Ch), 250MSa/s (3 or 4Ch)
Maximum Memory Depth 12Mpts (24Mpts Optional)
Maximum Waveform Capture Rate 30,000wfms/s
Time-Base Accuracy ≤±25ppm
Time-Base Drift ≤±5ppm/year
Time-Base Scale 5ns/div to 50s/div
Input Impedance 1MΩ ± 2% // 13pF ± 3pF
Vertical Scale 1mV/div to 10V/div
DC Gain Accuracy ±2% Full Scale (Channel 1), ±3% Full Scale (Channels 2, 3 & 4)
Bandwidth Limit 20MHz
Real Time Waveform Record &
Replay Function (Optional)
Up to 60,000 Frames
Standard Trigger Functions Edge, Pulse Width, Slope, Video, Pattern, Duration
Optional Trigger Functions RS232, I2C, SPI, Runt, Windows, Nth Edge, Delay, Time Out, Setup/Hold
Standard Bus Decoding Parallel Bus
Optional Bus Decoding RS232, I2C, SPI
Math Functions A+B, A-B, AxB, A/B, FFT, AND, OR, NOT, XOR, Intg, Diff, Sqrt, Lg, Ln, Exp, Abs
Auto Measurements Vpp, Vamp, Vmax, Vmin, Vtop, Vbase, Single Period Vavg, Vrms, Single Period Vrms,
Overshoot, Preshoot, Area, Period Area, Freq, Period, Rise Time, Fall Time, Width, -Width, Duty, -Duty,
Delay A→B Rising Edge, Delay A→B Falling Edge, Phase A→B Rising Edge, Phase A→B Falling Edge
Connectivity USB Host & Device, LAN(LXI), Aux Output (TrigOut, PassFail)
Support USB-GPIB (Optional)
Display 7" WVGA (800x480) TFT LCD, 64 Intensity Grading Level
Size (WxHxD) 313.1mm x 160.8mm x 122.4mm
Weight 3.2kg ± 0.2kg (without package)
Standard Probes RP2200 150MHz BW Passive Probe: 4 sets
Built-In 2 Channel Waveform Generator '-S' Models Only
2 Channels
200MSa/s Sample Rate
14bits Vertical Resolution
25MHz Maximum Output Frequency
20mVpp - 5Vpp Amplitude Range (High Z)
16kpts Waveform Length
Standard Waveforms - Sine, Square, Ramp, Pulse, Noise, DC
Arbitrary Waveforms - Sinc, ExpRise, ExpFall, ECG, Gauss, Lorentz, Haversine, User Defined
Modulation - AM & FM
MSO Ready Yes

Add 16 digital channels to your Rigol DS1000Z Plus oscilloscope simply by purchasing the Rigol MSO1000Z Upgrade Kit.

Please note - The number of available analogue channels is reduced by 1 for every block of 8 digital channels in use.
For example - If 9 to 16 digital channels are in use, the number of available analogue channels is 2.
 

All the specifications are guaranteed except parameters marked with “Typical” and the oscilloscope needs to operate for more than 30 minutes under the specified operation temperature.

Sample
Sample Mode Real-time Sample
Real-time Sample Rate Analog channel:
1 GSa/s (single-channel), 500 MSa/s (dual-channel), 250 MSa/s (three/four-channel)
Digital channel:
1 GSa/s (8-channel), 500 MSa/s (16-channel)
Peak Detect Analog channel: 4 ns Digital channel: 4 ns
Averaging After all the channels finish N samples at the same time, N can be 2, 4, 8, 16, 32, 64, 128, 256, 512 or 1024
High Resolution 12 bit (max.)
Interpolation Sin(x)/x (optional)
Minimum Detect Pulse Width Digital channel: 10 ns
Memory Depth Analog channel: standard 12 Mpts (single-channel), 6 Mpts (dual-channel), 3 Mpts (three/four-channel); optional 24 Mpts (single-channel), 12 Mpts (dual-channel), 6 Mpts (three/four-channel)
Digital channel:
standard 12 Mpts (8-channel), 6 Mpts (16-channel); optional 24 Mpts (8-channel), 12 Mpts (16-channel)
Input
Number of Channels MSO1XX4Z/1XX4Z-S: 4 analog channels, 3 analog channels+8 digital channels, 2 analog channels+16 digital channels
DS1XX4Z Plus/1XX4Z-S Plus: 4 analog channels, MSO upgradable
DS1054Z: 4 analog channels
Input Coupling DC, AC or GND
Input Impedance Analog channel:(1 MΩ±1%) || (15 pF±3 pF)
Digital channel:(100 MΩ±1%) || (8 pF±3 pF)
Probe
Attenuation
Coefficient
Analog channel:0.01X-1000X, 1-2-5 step
Maximum Input Voltage (1MΩ) Analog channel: CAT I 300 Vrms, CAT II 100 Vrms, transient overvoltage 1000 Vpk With RP2200 10:1 probe: CAT II 300 Vrms

Digital channel: CAT I 40 Vrms, transient overvoltage 800 Vpk
Horizontal
Time Base Scale 5 ns/div to 50 s/div
Maximum Record Length 24 Mpts (optional)
Time Base Accuracy [1] ≤ ± 25 ppm
Clock Drift ≤ ± 5 ppm/Year
Maximum Delay Range Negative delay: 1/2 (Memory Depth/Sample Rate)
Positive delay: 1 s to 500 s
Time Base Mode YT, XY, Roll
Number of X-Ys 1 path
Waveform Capture Rate [2] 30,000 wfms/s (dots display)
Zero Offset ±0.5div*minimum time base scale
Vertical
Bandwidth (-3dB) MSO1104Z/1104Z-S and DS1104Z Plus/1104Z-S Plus: DC to 100 MHz
MSO1074Z/1074Z-S and DS1074Z Plus/1074Z-S Plus: DC to 70 MHz
DS1054Z: DC to 50 MHz
Single-shot Bandwidth MSO1104Z/1104Z-S and DS1104Z Plus/1104Z-S Plus: DC to 100 MHz
MSO1074Z/1074Z-S and DS1074Z Plus/1074Z-S Plus: DC to 70 MHz
DS1054Z: DC to 50 MHz
Vertical Resolution Analog channel: 8 bits
Digital channel: 1 bit
Vertical Scale 1 mV/div to 10 V/div
Offset Range 1 mV/div to 499 mV/div: ± 2 V
500 mV/div to 10 V/div: ± 100 V
Bandwidth Limit1 20 MHz
Low Frequency Response
(AC coupling, -3dB)
≤5 Hz (on BNC)
Calculated Rise Time [1] MSO1104Z/1104Z-S and DS1104Z Plus/1104Z-S Plus: 3.5 ns
MSO1074Z/1074Z-S and DS1074Z Plus/1074Z-S Plus: 5 ns
DS1054Z: 7 ns
DC Gain Accuracy [3] <10 mV: ±4% full scale
≥10 mV: ±3% full scale
DC Offset Accuracy ±0.1 div ± 2 mV ± 1% offset
Channel to Channel
Isolation
DC to maximum bandwidth: >40 dB
Vertical (Digital Channel)(Applicable to MSO1000Z and DS1000Z Plus with MSO Upgrade Option)
Threshold Adjustable threshold of 8 channels per group
Threshold Selection TTL (1.4 V)
5.0 V CMOS (+2.5 V), 3.3 V CMOS (+1.65 V)
2.5 V CMOS (+1.25 V), 1.8 V CMOS (+0.9 V)
ECL (-1.3 V)
PECL (+3.7 V)
LVDS (+1.2 V)
0 V
User
Threshold Range ±15.0 V, in 10 mV step
Threshold Accuracy ±(100 mV + 3% of threshold setting)
Dynamic Range ±10.0 V + threshold
Minimum Voltage Swing 500 mVpp
Vertical Resolution 1 bit
Trigger
Trigger Level Range ±5 div from the center of the screen
Trigger Mode Auto, Normal, Single
Holdoff Range 16 ns to 10 s
High Frequency
Rejection
75 kHz
Low Frequency
Rejection
75 kHz
Trigger Sensitivity [1] 1.0div (below 5mV or noise rejection is enabled)
0.3div (above 5mV and noise rejection is disabled)
Edge Trigger
Edge Type Rising, Falling, Rising&Falling
Pulse Trigger
Pulse Condition Positive Pulse Width (greater than, lower than, within specified interval)
Negative Pulse Width (greater than, lower than, within specified interval)
Pulse Width Range 8 ns to 10 s
Runt Trigger
Pulse Condition None, > (greater than), < (lower than), <> (within the specified interval)
Polarity Positive, Negative
Pulse Width Range 8 ns to 10 s
Windows Trigger 
Windows Type Rising, Falling, Rising&Falling
Trigger Position Enter, Exit, Time
Windows Time 8 ns to 10 s
Nth Edge Trigger
Edge Type Rising, Falling
Idle Time 16 ns to 10 s
Number of Edges 1 to 65535
Slope Trigger
Slope Condition Positive Slope (greater than, lower than, within specified interval)
Negative Slope (greater than, lower than, within specified interval)
Time Setting 8 ns to 10 s
Video Trigger
Signal Standard Support standard NTSC, PAL and SECAM broadcasting standards
Support 480P, 576P HDTV standards
Pattern Trigger
Pattern Setting H, L, X, Rising Edge, Falling Edge
Delay Trigger
Edge Type Rising, Falling
Delay Type > (greater than), < (lower than), <> (within the specified interval), >< (outside the specified interval)
Delay Time 8 ns to 10 s
TimeOut Trigger 
Edge Type Rising, Falling, Rising&Falling
TimeOut Value 16 ns to 10 s
Duration Trigger 
Pattern Setting H, L, X
Trigger Condition > (greater than), < (lower than), <> (within the specified interval)
Duration Time 8 ns to 10 s
Setup/Hold Trigger 
Edge Type Rising, Falling
Data Pattern H, L,X
Setup Time 8 ns to 1 s
Hold Time 8 ns to 1 s
RS232/UART Trigger
Polarity Normal, Invert
Trigger Condition Start, Error, Check Error, Data
Baud 2400 bps, 4800 bps, 9600 bps, 19200 bps, 38400 bps, 57600 bps, 115200 bps, User
Data Bits 5 bits, 6 bits, 7 bits, 8 bits
I2C Trigger
Trigger Condition Start, Restart, Stop, Missing Ack, Address, Data, A&D
Address Bits 7 bits, 8 bits, 10 bits
Address Range 0x0 to 0x7F, 0x0 to 0xFF, 0x0 to 0x3FF
Byte Length 1 to 5
SPI Trigger
Trigger Condition TimeOut, CS
Timeout Value 16 ns to 10 s
Data Bits 4 bit to 32 bit
Data Line Setting H, L, X
Measure Manual mode | Voltage deviation between cursors (ΔV)
Time deviation between cursors (ΔT)
Reciprocal of ΔT (Hz) (1/ΔT)
Track mode | Voltage and time values of the waveform point
Auto mode | Allow to display cursors during auto measurement
Auto Measurement Measurements of Maximum, Minimum,
Peak-Peak Value, Top Value, Bottom Value,
Amplitude, Average, Mean Square Root,
Overshoot, Pre-shoot, Frequency, Period, Rise
Time, Fall Time, Positive Pulse Width, Negative
Pulse Width, Positive Duty Cycle, Negative
Duty Cycle, Delay A~B , Delay A~B , Phase
A~B , Phase A~B
Number of
Measurements
Display 5 measurements at the same time
Measurement
Range
Screen Region or Cursor Region
Measurement
Statistic
Counter
Average, Max, Min, Standard Deviation
Number of Measurements
Hardware 6 bits counter (channels are
selectable)
Math
Waveform A+B, A-B, A×B, A/B, FFT, A&&B, A||B, A^B, !A, Intg, Diff, Sqrt, Lg, Ln, Exp, Abs, Filter
FFT Window Rectangle, Hanning, Blackman, Hamming,Flat Top,Triangle
FFT Mode Trace, Memory
FFT Display Half, Full
FFT Vertical Scale dB/dBm, Vrms
Filter Low Pass Filter, High Pass Filter, Band Pass Filter, Band Stop Filter
Number of Buses
for Decoding
2
Decoding Type Parallel (standard), RS232/UART (option), I2C (option), SPI (option)
Display
Display Type 7.0 inches TFT LCD display
Display Resolution 800 horizontal×RGB×480 vertical pixel
Display Color 16 million color (24 bit true color)
Persistence Time Min, 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s, 20 s, Infinite
Display Type Dots, Vectors
I/O
Standard Ports USB HOST, USB DEVICE, LAN, Aux (TrigOut /PassFail)
Signal Sourse (DS1000Z-S) 
Number of Channels  2
Sample Rate  200 MSa/s
Vertical Resolution  14 bits
Highest  Frequency  25 MHz
Standard Waveform  Sine, Square, Pulse, Triangle, Noise, DC
Arbitrary Waveform  Since, Exp.Rise, EXP.Fall, ECG, Gauss, Lorentz, Haversine
Sine  Frequency Range  0.1 Hz to 25 MHz
 Flatness  ±0.5 dB (relative to 1 kHz)
 Harmonic Distortion  -40 dBc
 Stray (Non-Harmonic)  -40 dBc
 Total Harmonic Distortion  1%
 Signal-to-Noise ration  40 dB
Square/Pulse  Frequency Range  0.1 Hz to 15 MHz
 Rise/Fall time  <15 ns
 Overshoot  <5%
 Duty Cycle  10% to 90%
 Duty Cycle  Resolution  1% to 10 ns (select the greater one)
 Minimum Pulse Width  20 ns
 Pulse Width Resolution  10 ns or 5 bits (select the greater one)
 Jitter  500 ps
Triangle  Frequency Range  0.1 Hz to 100 kHz
 Linearity  1%
 Symmetry  0 to 100%
Noise [1]  Bandwidth 25 MHz
Internal Generated
waveforms
 Frequency Range  0.1 Hz to 1 MHz
Arbitrary Waveforms  Frequency Range  0.1 Hz to 10 MHz
 Waveform Length  2 to 16k pts
Frequency  Accuracy 100 ppm (lower than 10 kHz)
50 ppm (greater than 10 kHz)
 Resolution  0.1 Hz or 4 bit, select the greater one
Amplitude  Output Range  20 mVpp to 5 Vpp, High-resistance
10 mVpp to 2.5 Vpp, 50 Ω
 Resolution  100 μV or 3 bit, select the greater one
 Accuracy  2% (1 kHz)
DC Offset  Range  ±2.5 V, High-resistance
±1.25 V, 50 Ω
 Resolution  100 μV or 3 bit, select the greater one
 Accuracy  2% (1 kHz)
General Specifications
Probe Compensation Output
Output Voltage [1] About 3 V, peak-peak
Frequency [1] 1 kHz
Power
Power Voltage 100 V to 240 V, 45 Hz to 440 Hz
Power Maximum 50 W
Fuse 2 A, T degree, 250 V
Environment
Temperature Range In operation: 0°C to +50°C
Out of operation: -40°C to +70°C
Cooling Method Fan
Humidity Range 0° to +30°C : ≤95°C relative humidity
+35°C to +40°C : ≤75°C relative humidity
+40°C to +50°C : ≤45°C relative humidity
Altitude In operation: under 3,000 meters
Out of operation: under 15,000 meters
Mechanical
Dimensions [4] Width×Height×Depth =313.1 mm× 160.8 mm×122.4 mm
Weight [4] Without package | 3.2 kg ± 0.2 kg
With package | 3.8 kg ± 0.5 kg
Adjustment Interval
  The recommended calibration interval is one year.
Regulation Standards
Electromagnetic 2004/108/EC
Compatibility Execution standard EN 61326-1:2006 EN
61326-2-1:2006
Safety UL 61010-1:2004; CAN/CSA-C22.2 NO.
61010-1-2004;
EN 61010-1:2001; IEC 61010-1:2001

Rigol DS1104Z Plus Product Specifications Summary:
(for full specs please see the full specs tab or the data sheet)

Oscilloscopes/Digital Oscilloscopes Template

Bandwidth What's This?100 Mhz
Channels4
Sampling Rate What's This?1 GS/S
Memory What's This?12 MP [megapoints] (12288 kB)
Rise Time What's This?3.5 ns
Screen Type (Oscilloscopes)TFT/LCD
Screen Size7 IN
Bits What's This?8
Battery OptionsNo

Test Equipment General Attributes

Unique FeaturesDigital Logic Connector for optional MSO upgrade
Warranty3 YEARS
Calibration IncludedFactory Calibration
Power Supply Voltage120V/220V Universal
Safety ApprovalCE, CSA
Data Logging What's This?Yes
Interfaces I/O LAN / Ethernet, LXI, USB Host, USB
Product Weight3.2 KILOS (7.05 LBS)
Shipping Weight4.2 KILOS (9.26 LBS)
ECCN Number3A992
HTS/Schedule B Number9030201500
Country of OriginChina

Reviews

Q & A

Q: Does the Rigol DS1074Z have the ability to record and play data from memory?
A: Yes. The DS1074Z does have record and playback functions. See the REC-DS1000Z option.

Q: Do you need the AT-DS1000Z Advanced Trigger Option to use the SA-DS1000Z Serial Bus Decoding with the Rigol DS1074Z?
A: No, you do not. You can manually set your triggers and then decode what you captured. However, it makes the process much, much easier if you have correct triggers already built.

Q: When I capture a single trigger event, the only waveform information that is captured is whats on the screen, what can I do to get more capture time ?
A: What you need to do is change ( increase ) the memory depth manually. By default it is in AUTO mode. To increase the memory depth manually, press the ACQUIRE button, then select MEM DEPTH off the display menu, then use the multifunction knob and take it out of AUTO mode and set it the required memory depth. What is usually suggested as a starting point is the setting just before the maximum setting. Recapture the single triggered event and adjust the horizontal knob to move the displayed waveform left or right and confirm that you have captured a longer record length.
Also be aware that the memory depth decreases for each channel that is turned on and this in turn decreases the record length of the capture.

Q: Could you confirm the maximum input voltage for the DS1074Z, using a 1x probe?
A: The Rigol DS1054Z comes with the RP2200 probes. In the 1x mode, the maximum input voltage is: 150Vrms. When in the 10x mode, the maximum input voltage is: 300Vrms. This is approximately equal to 425 VDC, if you consider the peak value. However, its always advised to use a DC Blocking capacitor when working with tube amplifiers with plate voltages over 300 Vdc.

Q: Is there a -S version of the DS1074Z with a built in generator?
A: The DS1074Z has a DS1074-S version with a built in generator.

Q: Is there a M version of the DS1074Z with logic analyzer option?
A: The Rigol DS1074Z does not have a -M version with Logic analyzer.  The MSO1074Z is the 70 Mhz version of this unit with the logic analyzer built in.  This is a hardware change and cannot be added after the purchase.  Keep in mind that Serial Bus Decoding with the Rigol DS1074Z can be done with the SA-DS1000Z software option.

Q: Why is the DS1074Z so inexpensive?
A: This is a question we often get asked about this unit.  It looks fantastic.  Why is it so inexpensive?  The answer to this is somewhat of an opinion here at TEquipment but Rigol wants market share.  They are making waves by having such a great unit at an unbelievable price. We like to see read the reviews.  Our customers write honest feedback. This unit is simply an AMAZING value.

Q: I am having trouble with my clip attachments staying on. How can I fix this?
A: Simply press the hook tip firmly in order to connect. You can view more information on this topic HERE!

Q: Can the Rigol DS1074Z show me harmonic content and distortion?
A: Yes it can by utilizing the FFT Math function. You can find the information in the User Guide on page 6-16.
FFT (Fast Fourier Transform) is used to transform time domain signals to frequency
domain components (frequency spectrum).
MSO1000Z/DS1000Z oscilloscope provides FFT operation function which enables users to observe the time domain waveform and spectrum of the signal at the same time. FFT operation can facilitate
the following works:
  • Measure harmonic components and distortion in the system
  • Display the characteristics of the noise in DC power
  • Analyze vibration
Q: When I capture a single trigger event, the only waveform information that is captured is whats on the screen, what can I do to get more capture time ?
A: What you need to do is change ( increase ) the memory depth manually. By default it is in AUTO mode. To increase the memory depth manually, press the ACQUIRE button, then select MEM DEPTH off the display menu, then use the multifunction knob and take it out of AUTO mode and set it the required memory depth. What is usually suggested as a starting point is the setting just before the maximum setting. Recapture the single triggered event and adjust the horizontal knob to move the displayed waveform left or right and confirm that you have captured a longer record length.
Also be aware that the memory depth decreases for each channel that is turned on and this in turn decreases the record length of the capture.

Q: Is there a way to tell which displayed trace is what channel when I am using more than one channel ? Are the trace colors configurable?
A: The individual trace colors are not configurable, however, each of the displayed traces are different colors that match the color indicated just over the channel connector. Additionally, there are channel labels to the left of the trace which display the number of the corresponding channel for that trace. These labels can be edited. Its important to note that if there is a DC OFFSET on the signal then the trace marker will be offset as well; making it a little more difficult to identify the trace. As a last resort setting the scope to the channel in question and utilizing the vertical position control will also reveal which trace.

Q: When I use the X-Y mode, the refresh rate is really slow. Is there a way to increase it?
A: Yes, when using the X-Y mode, you need to take the memory depth out of AUTO and change it to 6 K.  This will increase the update rate substantially.

Accessories

Loading Accessories

Reviews

Rigol DS1104Z Plus Customer Reviews

0 Reviews
5 stars
 (0)
4 stars
 (0)
3 stars
 (0)
2 stars
 (0)
1 star
 (0)
 
 
 
 
 
Average Customer Review
         
0 reviews
0 customer reviews
Share your thoughts with other customers
Create your own review
No reviews found to display for this rating.

Rigol Price List

Learn Before You Buy
Checkout Our Guides!

GW Instek MSO-2000 series mixed signal oscilloscopes
X


secured website

Interworld Highway, LLC dba TEquipment.NET

205 Westwood Avenue. Long Branch, NJ 07740

Privacy Policy | Terms and Conditions | Site Map

Copyright© 2016 Interworld Highway, LLC

secured website
We Price Match!

Give our sales team a call at 877.571.7901 (Toll Free) or 732.222.7077 (International) and we'll match any competitor's price.

X