Megger MIT2500 2500V Insulation Tester

 
Our Customers get the best price
Megger MIT2500
Catalog #: 1006-764
         
0 reviews
2.5 kV insulation, continuity, capacitance and result storage and downloading

Features

  • Insulation testing up to 2.5 kV and 200 GΩ range in a hand held instrument
  • Guard terminal for high resistance accuracy
  • Adjustable insulation test voltage from 50 V to 2500 V
  • Stabilised insulation test voltage
  • Rechargeable options for mains and car charging
  • Single range, faster continuity testing from 0.01 Ω to 1 MΩ
  • Polarisation Index (PI) & Dielectric Absorption Ratio (DAR)
  • CAT IV 600 V applications
Loading Prices
List Price: $1,495.00
Questions?
Ask Our Factory
Trained Engineers
M-F 8AM - 9PM EST
• 877.571.7901

Compare Products in this Series

Product Name Type IR Test Voltage Maximum Insulation Resistance Availability Price
MIT2500
MIT2500
2.5 kV insulation, continuity, capacitance and result storage and...
Battery 1,000 V, 125V, 2,500 V, 250 V, 50 V, 500 V 200 G Ohms
MIT400/2
MIT400/2
MIT400/2-LG2 (EN ES PT IT) Insulation And Continuity Tester...
Battery 1,000 V, 250 V, 500 V 200 G Ohms
MIT410/2
MIT410/2
MIT410/2-LG2 (EN ES PT IT) Insulation And Continuity Tester...
Battery 1,000 V, 100 V, 250 V, 50 V, 500 V 200 G Ohms
MIT420/2
MIT420/2
MIT420/2-LG2 (EN ES PT IT) Insulation And Continuity Tester...
Battery 1,000 V, 100 V, 250 V, 50 V, 500 V 200 G Ohms
MIT430/2
MIT430/2
MIT430/2-LG2 (EN ES PT IT) Insulation And Continuity Tester...
Battery 1,000 V, 100 V, 250 V, 50 V, 500 V 200 G Ohms
MIT481/2
MIT481/2
MIT481 INSULATION TESTER EN 50/100/250/500/1000V Telecommunications +...
Battery 100 V, 250 V, 50 V, 500 V 100 G Ohms
MIT485/2
MIT485/2
MIT485 INSULATION TESTER EN 50/100/250/500/1000V Telecommunications +...
Battery 10 V, 100 V, 250 V, 50 V, 500 V 100 G Ohms
MIT415/2
MIT415/2
MIT415/2-LG2 (EN ES PT IT) Insulation and Continuity Tester...
Battery 1,000 V, 100 V, 250 V, 50 V, 500 V 200 G Ohms
Megger MIT2500 2500V Insulation Tester

Megger MIT2500 2500V Insulation Tester

         
0 reviews

Product Information

Megger MIT2500 2500V Insulation Tester

×

Megger MIT2500 2500V Insulation Tester


Test Voltages (New)

50 V, 100 V, 250 V, 500 V, 1000 V, and 2500 V
 

Guard Terminal

Improved performance on higher insulation test ranges
 

2.5 kV Silicone Test Leads (New)

Purpose designed high 2.5 kV silicone test leads are included as well as standard 1000 V CAT III / 600 V CAT IV general purpose test leads.
 

Variable Test Voltage (New)

Adjustable test voltage from 50 V to 999 V in 1 V steps, 1000 V to 2500 V in 10 V steps
 

2% Test Voltage Accuracy

The output test voltage is maintained within the tolerance of -0% +2% +2 V


Stabilised Test Voltage

The voltage is feedback controlled to ensure it remains within specification throughout the full test range


Test Voltage Display (New)

The actual test voltage is displayed on the smaller digital readout, with the measurement on the larger digital display.

Measurement Range Displayed

The range voltage is displayed during selection.
 

Measurement Voltage Display (New)

The measurement voltage is displayed during the test.
 

Analogue Arc

The display also features an analogue arc to replicate the response of a moving coil display.


PI and DAR

Automatic Polarisation Index (PI) and Dielectric Absorption Ratio (DAR) functions. Polarisation Index (PI):10 min / 1 minute ratio Dielectric Absorption Ratio (DAR): 60 sec / 30 sec ratio.
 

Timed Testing

Automatically test to a time limit.
 

200 GΩ Range

Insulation testing up to 200 GΩ at ≥1000 V.
 

Test Inhibit

prevents testing if voltages in excess of 25, 30, 50, 75 or 100 V (set by the user) are detected when making insulation tests. Default is 50 V.
 

Insulation Buzzer

The buzzer can be set to sound if the insulation resistance is above a user adjustable limit, configurable in the Setup menu.
 

Test Lock

Holds insulation test on continuously.

 

OVERVIEW

 
The MIT2500 Insulation and Continuity Tester has been designed for motor and cable testing, specialist applications and electrical testing  applications, where operation voltages exceed 1000 V and higher insulation test voltages are needed.

The MIT2500 offers both fixed range voltages of 50 V, 100V, 250 V, 500 V, 1000 V and 2500 V, as well as a variable range that allows any voltage between 50 V and 2500 V to be “dialled in”. This is supported by the new test voltage feedback control, which maintains the output test voltage to within 2% of the selected range, even when under test.

The MIT2500 uses the redesigned case, back-stand, and 6 cell battery compartment, as well as incorporating a Guard terminal to reduce surface tracking currents that reduce accuracy at higher voltages.

All instruments are over-moulded for increased protection and achieve an IP54 weatherproof rating.
 

Insulation Resistance Testing

The feedback controlled insulation test voltage is now accurate to +2% -0% compared to the original +20%, providing a more accurate test voltage without the risk of over-voltage damage to circuits.
 

A variable range allows the exact test voltage to be selected from 50 V to 999 V in 1 V steps, (1KV to 2.5KV in 10 V steps) providing 1100 test voltage options.

 

Variable Insulation Voltage (NEW)*

The variable mode provides a unique solution for awkward insulation voltage measurement applications. The range option allows an insulation test voltage from 50 V to 999 V in 1 V steps, 1.0 KV to 2.5 KV in 10 V steps.

TYPICAL APPLICATIONS INCLUDE

  • Commercial Avionics
  • Military Land, Marine and Air communications
  • Manufacturing/production line goods
  • Electrostatic measurement
  • Component testing
  • Battery powered traction and lifting equipment

Guard Terminal

The Guard terminal (G) is a third terminal on the connection panel. Connection of the guard terminal on certain applications provides a return path for parallel leakage currents that could otherwise create significant errors in the insulation measurement. This is especially so for surface contamination of equipment or cables.
  • For voltages of 1000 V and above, or expected insulation values over 100 MΩ the guard terminal should be considered to reduce measurement error.

Voltage Measurement

True RMS voltage measurement to 600 V ac or dc with resolution from 0.1 mV.
  • Digital voltage measurement up to 600 V ac/dc
  • Automatic display of frequency during voltage measurement.

Display

The display offers a combination of Analogue arc and a dual digital readout:

Analogue arc:
  • Full display width analogue arc.
  • Arc display shows essential charge and discharge characteristics not visible on a digital display.
  • Single pointer “needle” response has a similar response to a moving coil meter.
Dual digital display
  • Large main digital readout for good visibility of all main measurement results
  • Second digital display for additional data such as:
    • Insulation test voltage.
    • Insulation leakage current.
    • Supply frequency (when measuring volts).
    • Test mode eg. PI, DAR or t (t = Timer mode).

Application

Building wiring installations:

  • Conductor isolation

  • Fault identification

  • Cable commissioning pre-pressure test

  • Cable leakage issues

  • Installation damage

  • Breaker disconnection time conformance

Medical locations:

  • Low resistance earth continuity

  • Touch voltage testing

  • Circuit isolation

  • Faraday cage construction

  • Earth star point bonding


Electric Vehicle testing:

  • Battery conductor isolation

  • Bonding continuity

  • Vehicle discharge

  • Vehicle servicing

Vehicle testing

  • Solenoid testing

Panel building

  • LV Switchgear commissioning

  • PFC cubicles

  • Control panels

  • Changeover panels

  • Package substations

  • UPS Input / Output panels

Wind turbines – manufacturing and installation

  • Winding wire isolation/cracking

  • Slot insulation

  • Impregnation resin integrity

  • Turns ratio measurement

Motor/generator testing

  • Winding to ground isolation

  • Inter-winding isolation

  • Short duration testing

  • Turns resistance

  • Voltage output

FUNCTIONAL SUMMARY
INSULATION
50 V / 100 V
250 V / 500 V / 1000 V
2500 V
VARIABLE voltage from 50 V to 2500 V
PI- / DAR / timed
Lock button on MΩ
Guard terminal
CONTINUITY
Continuity 0.01 Ω - 1 MΩ
Auto reverse polarity (setup ON-OFF)
Lead null (<10 Ω)
VOLTAGE
AC / DC Volts 600 V
mV AC / DC range
Frequency measurement 15 - 400 Hz
Input impedance 250 kΩ
CAPACITANCE
Capacitance 0.1 nF - 10 μF
OTHER FEATURES
PASS/FAIL on limit alarms
Auto power down (setup)
Onboard memory
Bluetooth® Download and Software
AA Alkaline or niMH
Recharger ready
CAT IV 600 V
ACCESSORIES
Silicone leads (Red/Black/Blue with probes and clips)
2.5 kV Silicone croc clip leads
OPTIONAL Switched probe supplied
OPTIONAL Battery charger available

 

Battery Layout

 

×

Battery Layout

  • Six cells add 20% battery life
  • Fuse location moved to secondary cover
  • More cost effective operation
  • Single screw cover

Fuse Relocation

 

×

Fuse Relocation


×

Interfering with Battery Changes

  • Separate fuse cover
  • Improved security (seal placement)
  • Allows calibration seals without interfering with battery changes

What's In The Box

  • Set of Silicone Test Leads with Prods and Clips (Red/Black/Blue)
  • 2.5 kV Silicone Test Leads with Clips (Red/Black/Blue)
  • Owners Information CD
  • AA Alkaline Batteries
  • Carrying Case
  • Factory calibration certificate

Specifications

SPECIFICATIONS
All quoted accuracies are at +20 °C.
Insulation
Insulation accuracy
50 Volts 10 GΩ ± 2% ± 2 digits ± 4.0% per GΩ
100 Volts 20 GΩ ± 2% ± 2 digits ± 2.0% per GΩ
250 Volts 50 GΩ ± 2% ± 2 digits ± 0.8% per GΩ
500 Volts 100 GΩ ± 2% ± 2 digits ± 0.4% per GΩ
1000 Volts 200 GΩ ± 2% ± 2 digits ± 0.2% per GΩ
2500 Volts 200 GΩ ± 2% ± 2 digits ± 0.2% per GΩ
Service Error BS EN 61557-2 (2007).
50V, ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.5%
100V, ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3%
250V, ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3%
500V, ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3%
1000V, ± 2.0% ± 2d, 100kΩ - 900kΩ ± 11.5%
Guard terminal performance <5% error at 500 kΩ parallel circuit resistance with 100 MΩ load
Display range Analogue: 1 GΩ full scale
Resolution 0.1 kΩ
Short circuit/charge current 2 mA +0% -50% to EN 61557-2 (2007) (except 2500 V)
Terminal voltage accuracy -0% +2% ± 2V
Test current 1 mA at min. pass value of insulation to a maximum of 2 mA max
Operation EN61557 : 0.10 MΩ to 1.0 GΩ
Leakage current display 10% ±3 digits
Voltage ±3% ±2 digits ±0.5% of rated voltage
Timer control Countdown timer 60 second (adjustable to 10 minutes)
Note Above specifications only apply when high quality silicone leads are being used.
Continuity
Continuity measurement 0.01 Ω to 1 MΩ (0 to 1000 kΩ on analogue scale)
Continuity accuracy ± 3% ± 2 digits (0 to 100 Ω )
± 5% ± 2 digits (100 Ω - 500 k Ω)
Service Error BS EN 61557-4 (2007) -
± 2.0%, 0.1Ω - 2Ω ± 6.8%
Open circuit voltage 5 V ± 1 V
Test current 200 mA (–0 mA +20 mA) (0.01 Ω to 4 Ω)
Polarity Single polarity (Default) / Dual polarity (configurable on setup).
Lead resistance Null up to 10 Ω
Voltage range DC: 0 to 600 V
AC: 10 mV to 600 V TRMS sinusoidal (15 Hz to 400 Hz)
Unspecified: 0 – 10 mV (15 to 400 Hz)
Volt range accuracy DC: ± 2% ± 2 digits
AC: ± 2% ± 2 digits
Waveform Non-sinusoidal:
± 3% ± 2 digits >100 mV to 600 V TRMS
± 8% ± 2 digits 10 mV to 100 mV TRMS
Default voltmeter ± 0.5% ± 1digit (100 Hz to 400 Hz) unspecified
Frequency measurement range 15 Hz - 400 Hz
Frequency measurement accuracy ± 0.5% ± 1 digits
Capacitance measurement
Capacitance range 0.1 nF to 10 µF
Accuracy ± 5.0% ± 2 digits ( 1 nF-10 µF)
Results storage
Storage capacity >1000 test results
Data download Bluetooth® wireless
Bluetooth® Class II
Range up to 10 m
Power supply 6 x 1.5 V cells type IEC LR6
(AA, MN1500, HP7, AM3 R6HP) Alkaline

6 x 1.2 NiMH rechargeable cells may be used.
Battery life 3000 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ
Charger (Optional): 12-15 V dc (accessory interface)
Dimensions Instrument 228 mm x 108 mm x 63 mm (9.00 in x 4.25 in x 2.32 in)
Weight 815 g, (1.8 lb)
Weight (instrument and case) 1.75 kg (3.86 lb)
Fuse Use only 2 x 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse of high breaking capacity
HBC 30 kA minimum. Glass fuses MUST
NOT be fitted
Safety protection The instruments meet EN 61010-1 (1995) to 600 V phase to earth, Category IV. Refer to safety warnings supplied
EMC In accordance with IEC 61326 including amendment No.1
Temperature coefficient
<0,1% per °C up to 1 GΩ
<0,1% per °C per GΩ above 1 GΩ
Environmental
Operating temperature range -10 °C to +55 °C
Humidity 90% RH at 40 °C max
Storage temperature range -25°C to +70 °C
Calibration temperature +20 °C
Maximum altitude 2000 m
IP rating IP 54

Megger MIT2500 Product Specifications Summary:
(for full specs please see the full specs tab or the data sheet)

Micro / Milli / Meg Ohmmeters/Megohmmeter / Insulation Resistance Testers Template

Type What's This?Battery
IR Test Voltage What's This?1,000 V, 125V, 2,500 V, 250 V, 50 V, 500 V
Maximum Insulation Resistance200 G Ohms
Variable Incremental Voltage What's This?Yes 
Display (Megohmmeter) What's This?Digital
Continuity TestYes
Live Circuit Voltage Detection What's This?Yes
Automated Test Results What's This?Dielectric Absorption Ratio, Other
Power SupplyBattery
TimerYes
CAT Rating What's This?IV
CAT Voltage What's This?600 V

Test Equipment General Attributes

Calibration IncludedFactory Calibration
Power Supply Voltage120V 50/60 Hz
Data Logging What's This?No
IP Rating What's This?IP54
Battery TypeAA, NimH 
Country of OriginUnited Kingdom

Reviews

Accessories

Loading Accessories

Reviews

Megger MIT2500 Customer Reviews

0 Reviews
5 stars
 (0)
4 stars
 (0)
3 stars
 (0)
2 stars
 (0)
1 star
 (0)
 
 
 
 
 
Average Customer Review
         
0 reviews
0 customer reviews
Share your thoughts with other customers
Create your own review
No reviews found to display for this rating.

Megger Price List

X


secured website

Interworld Highway, LLC dba TEquipment.NET

205 Westwood Avenue. Long Branch, NJ 07740

Privacy Policy | Terms and Conditions | Site Map

Copyright© 2016 Interworld Highway, LLC

secured website
We Price Match!

Give our sales team a call at 877.571.7901 (Toll Free) or 732.222.7077 (International) and we'll match any competitor's price.

X