Fluke 1744
Catalog #: 2583422
         
0 reviews
POWER QUALITY LOGGER - MEMOBOX
Free Gift From Fluke With Purchase

Features

  • Rugged and reliable: Designed for everyday field use with no moving parts and durable insulated case with two year warranty 
  • Installs inside the cabinet: Compact, fully-insulated housing and accessories fit easily in tight spaces next to live power
  • Plug and play: Setup in minutes with automatic current probe detection and powering
  • Measure voltage with premium accuracy: IEC61000-4-30 Class-A compliant voltage accuracy (0.1%)
  • Determines the root cause: Included PQ Log software quickly analyzes trends, creates statistical summaries, and generates detailed graphs and tables
  • Monitors power for the long-term: Data can be downloaded during recording without interruption
  • Quickly validate quality of power: Assess power quality according to EN50160 power quality standard with statistical overview
Loading Prices
Sale: $6,999.99
  + Free shipping over $99

Marketing-Promo-Add-to-Cart-176x92-3-items

Questions?
Ask Our Factory
Trained Engineers
M-F 8AM - 9PM EST
• 877.571.7901

Compare Products in this Series

Product Name Input(power loggers) Type(Power loggers) Maximum Current AC Availability Price
1744
1744
POWER QUALITY LOGGER - MEMOBOX
Single Phase, Three Phase Plug & Play 3000 A
1743 BASIC
1743 BASIC
POWER QUALITY LOGGER (WITHOUT PROBES)
Single Phase, Three Phase Plug & Play 3000 A
1744/1PH
1744/1PH
POWER QUALITY LOGGER, 1 PHASE
Single Phase, Three Phase Plug & Play 3000 A
1743
1743
POWER QUALITY LOGGER - MEMOBOX
Single Phase, Three Phase Plug & Play 3000 A
1744 BASIC
1744 BASIC
POWER QUALITY LOGGER (WITHOUT PROBES)
Single Phase, Three Phase Plug & Play 3000 A
Fluke 1744

Fluke 1744 Power Quality Logger Memobox

         
0 reviews
  Add to cart

Product Information

Power quality logging is easy with a compact and rugged Fluke power meter

The Fluke 1740 Series three-phase power quality loggers are everyday power meters for technicians who troubleshoot and analyze power quality issues. Capable of simultaneously logging up to 500 power parameters for up to 85 days and monitoring for events, these power loggers help uncover intermittent and hard-to-find power quality issues. The included PQ Log software quickly assesses the quality of power at the service entrance, substation, or at the load, according to the latest EN50160 standard.

Applications

  • Disturbance analysis - Uncover root cause of equipment malfunction for later mitigation and predictive maintenance
  • Quality of service compliance - Validate incoming power quality at the service entrance
  • Power quality studies - Assess baseline power quality to validate compatibility with critical systems before installation
  • Load studies - Verify electrical system capacity before adding loads
  • Energy and power quality assessment - Validate performance of facility improvements by quantifying energy consumption, power factor, and general power quality before and after improvements

Loggers for every application

The portable Fluke 1740 Series power quality loggers are designed for easy installation and use, anywhere in low- and medium-voltage applications. There are three models to choose from to meet your basic or advanced power logging needs.

Fluke 1743: IP65 water-proof monitor for logging the most common power parameters including V, A, W, VA, VAR, PF, energy, flicker, voltage events, and THD.

Fluke 1744: Includes the same features as the Fluke 1743. In addition to common power parameters, the Fluke 1744 also measures voltage and current harmonics, interharmonics, mains signaling, unbalance, and frequency.

Fluke 1745: Advanced IP50 power quality logger with the same measurement capability as the 1744, plus real-time LCD, five hour UPS.

Product Feature Fluke 1745 Fluke 1744 Fluke 1743
Measurement of common power parameters: V, A, W, VA, VAR, PF, energy, flicker, voltage events, and THD
Measurement of voltage and current harmonics to the 50th, unbalance, and mains signaling  
Dust/water resistance IP50 IP65 water proof IP65 water proof
Display LED + LCD LED LED
UPS ride-through 5 hrs 3s 3s
Dimensions (HxWxD) 282 x 216 x 74 mm (11.5 x 8.8 x 3 in.) 170 x 125 x 55 mm (6.9 x 5.1 x 2.2 in.) 170 x 125 x 55 mm (6.9 x 5.1 x 2.2 in.)

What's In The Box

  • Printed English manual
  • Color localization kit
  • RS232 interface cable and RS232-USB adapter
  • 4 Flexible probes 15/150/1500/3000 A with 2 m cable
  • CD-ROM with PQ Log software
  • Test leads for voltages and power supply
  • 4 black dolphin clips
  • Carrying bag
  • Test certificate with measurement values
  • Multi-language manual CD

Specifications

General Data
Intrinsic error Refers to the reference conditions and is guaranteed for two years
Warranty 2 years
Recalibration interval 2 years recommended
Quality system developed, designed, and manufactured according to DIN ISO 9001
Reference conditions
  23 °C ± 2 K; 74 °F ± 2 K , Vm=230 V ± 10%, 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Phase sequence: L1, L2, L3
Interval length: 10 minutes
Wye connection: (L1, L2, L3 to N)
Power supply: 88 V ... 265 V AC
Environment conditions
Working temperature range: -10 °C to 55°C; 14 °F to 131°F
Operating temperature range: 0 °C to 35°C; 32 °F to 95°F
Storage temperature range: -20 °C to 60°C; -4 °F to 140°F
Reference temperature range: 23 °C ± 2 K; 74 °F ± 2 K
Relative humidity: Fluke 1745: Class B2 acc. IEC 60654-1
Fluke 1744/43: Class C2 acc. IEC 60654-1
Housing robust, fully insulated housing and accessories
Protection type
Fluke 1745: IP50 as per EN 60529
Fluke 1744/1743: IP65 as per EN 60529
Safety IEC/EN 61010-1 600 V CAT III, 300 V CAT IV, pollution degree 2, double insulation
Type test voltage 5.2 kV rms, 50 Hz / 60 Hz, 5 s
EMC
Emission: IEC/EN 61326-1, EN55022
Immunity: IEC/EN 61326-1
Voltage and Current Measurement
Input voltage
Input range VI P-N: max 480 V AC
Input range VI P-P: max 830 V AC
Max. overload voltage: 1.2 VI
Input range selection: By job programming
Connections: P-P or P-N, 1- or 3-phase
Nominal voltage VN: <= 999 kV with PTs and ratio
Input resistance: App. 820 kΩ per chan. Lx-N Single phase (L1 or A, L2 or B, L3 or C connected): app. 300 kΩ
Intrinsic uncenrtainty: 0.1 % of VI
Voltage transformer: Ratio: <999 kV / VI
Ration selection: By job programming
Current input with Flexi Set
Input ranges II L1 or A, L2 or B, L3 or C, N: 15 A / 150 A / 1500 A / 3000 A ac
Measuring range: 0.75 A … 3000 A ac
Position influence: Max. ± 2 % of measured value – for distance conductor to meas. head > 30 mm
Stray field influence: < ± 2 A ac for Iext=500 A ac and distance to measuring head > 200 mm
Temperature coefficient: < 0.05 % / K
Current transformer: Ratio <= 999 kA / II
Ratio selection: By job programming
Connection: 3-phase, 3-phase +N, 2 phase L1 or A and L3 or C (2 W-meter-method) 7 pole connector
Current input for clamp
Input ranges II L1 or A, L2 or B, L3 or C, N: 0.5 V nominal (for II) 1.4 Vpeak
Intrinsic uncertainty: < 0.3 % of II
Max. overload: 10 V ac
Input resistance: App. 8.2 kΩ
Current transformer: Ratio Ω 999 kA / II
Power systems Delta, 2-Element Delta, Wye, Single Phase, Split Single Phase
Logger
Power supply
Functional Range: 88 V to 660 V absolute, 50 Hz / 60 Hz
100 V to 350 V dc Internal fuse: 630 mA T
Power consumption: 5 Watts
Ride through: Fluke 1745: Internal battery for typ. > 5 hours ride through with intelligent power management
Fluke 1743/44: 3 sec Capacitor
Fuse: Power supply fuse can be replaced in service facility only. Supply can be connected in parallel to measuring inputs (up to 660 V)
Display, indicators LEDs for status and voltage levels
Fluke 1745: LC-display with backlight for voltage, current, active power, phase sequence.
Memory
Intervals: Capacity 8 MB Flash-EPROM
A function > 12000 intervals for > 85 days with 10 min intervals
P function > 30000 intervals for > 212 days with 10 min intervals
Events: > 13000
Memory model: linear, circular
Interface RS 232, 9600...115 000 Baud, automatic Baud rate selection, 3-wire communication
Dimensions
Fluke 1745: 282 mm x 216 mm x 74 mm (115in x 88in x 33in)
Fluke 1743/1744: 170 mm x 125 mm x 55 mm (69in x 51in x 22in)
Weight
Fluke 1745: approx. 3 kg
Fluke 1743/1744: approx. 2 kg
Measurement
A/D converter: 16 bit, sample rate: 10.24 kHz
Anti-aliasing filter: FIR-Filter, fc =4.9 kHz
Frequency response: Uncertainty < 1 % of Vm for 40 Hz to 2500 Hz
Interval length: 1, 3, 5, 10, 30 s, 1, 5, 10, 15, 60 minutes
Averaging time for Min/max values: ½, 1 mains period, 200 ms,1 , 3 , 5 s
Time base: Resolution: 10 ms (at 50 Hz), deviation: 2s/day at 23 °C; 74 °F ± 2 K

Fluke 1744 Product Specifications Summary:
(for full specs please see the full specs tab or the data sheet)

Power Measurement/Power Loggers Template

Input(power loggers) What's This?Single Phase, Three Phase
Type(Power loggers)Plug & Play
Maximum Current AC What's This?3000 A 
Maximum Voltage AC830 V 
True RMS What's This?No
Power Quality What's This?Yes
Current Input Channels1, 2, 3, 4
Voltage Input Channels1, 2, 3, 4
Measurement Frequency50 Hz, 60 Hz
Display (Energy Management)Digital 
Transient Capture What's This?No
Displays Waveform What's This?Yes 
Energy What's This?Yes
Phasor Diagrams What's This?No
Power Factor (Power Quality) What's This?Yes
Harmonics What's This?Yes
Total Harmonic Distortion What's This?Yes
Current Clamps IncludedYes
Blue Tooth CompatableNo
CAT Rating What's This?IV 
CAT Voltage Rating (V) What's This?300V, 600V

Test Equipment General Attributes

Unique FeaturesThe portable Fluke 1740 Series power quality loggers are designed for easy installation and use, anywhere in low- and medium-voltage applications.
There are three models to choose from to meet your basic or advanced power logging needs:
Fluke 1744 - Includes the same features as the Fluke 1743. In addition to common power parameters, the Fluke 1744 also measures voltage and current harmonics, interharmonics, mains signaling, unbalance, and frequency.
Warranty2 YEARS
Calibration IncludedNone
Power Supply Voltage120V/220V Universal
Data Logging What's This?Yes
Interfaces I/O RS-232, USB
IP Rating What's This?IP65
Product Weight4.5 LBS
Product Height69 IN
Product Length51 IN
Product Width22 IN
Country of OriginRomania
Other Information

Intrinsic error: Refers to the reference conditions and is guaranteed for two years

Warranty: 2 years

Recalibration interval: 2 years recommended

Quality system: developed, designed, and manufactured according to DIN ISO 9001

 : 23 ?C ? 2 K; 74 ?F ? 2 K , Vm=230 V ? 10%, 50 Hz ? 0.1 Hz or 60 Hz ? 0.1 Hz

Phase sequence:: L1, L2, L3

Interval length:: 10 minutes

Wye connection:: (L1, L2, L3 to N)

Power supply:: 88 V ... 265 V AC

Working temperature range:: -10 ?C to 55?C; 14 ?F to 131?F

Operating temperature range:: 0 ?C to 35?C; 32 ?F to 95?F

Storage temperature range:: -20 ?C to 60?C; -4 ?F to 140?F

Reference temperature range:: 23 ?C ? 2 K; 74 ?F ? 2 K

Relative humidity:: Fluke 1745: Class B2 acc. IEC 60654-1
Fluke 1744/43: Class C2 acc. IEC 60654-1

Housing: robust, fully insulated housing and accessories

Fluke 1745:: IP50 as per EN 60529

Fluke 1744/1743:: IP65 as per EN 60529

Safety: IEC/EN 61010-1 600 V CAT III, 300 V CAT IV, pollution degree 2, double insulation

Type test voltage: 5.2 kV rms, 50 Hz / 60 Hz, 5 s

Emission:: IEC/EN 61326-1, EN55022

Immunity:: IEC/EN 61326-1

Input range VI P-N:: max 480 V AC

Input range VI P-P:: max 830 V AC

Max. overload voltage:: 1.2 VI

Input range selection:: By job programming

Connections:: P-P or P-N, 1- or 3-phase

Nominal voltage VN:: = 999 kV with PTs and ratio

Input resistance:: App. 820 kO per chan. Lx-N Single phase (L1 or A, L2 or B, L3 or C connected): app. 300 kO

Intrinsic uncenrtainty:: 0.1 % of VI

Voltage transformer:: Ratio: 999 kV / VI

Ration selection:: By job programming

Input ranges II L1 or A, L2 or B, L3 or C, N:: 15 A / 150 A / 1500 A / 3000 A ac

Measuring range:: 0.75 A ? 3000 A ac

Position influence:: Max. ? 2 % of measured value ? for distance conductor to meas. head 30 mm

Stray field influence:: ? 2 A ac for Iext=500 A ac and distance to measuring head 200 mm

Temperature coefficient:: 0.05 % / K

Current transformer:: Ratio = 999 kA / II

Ratio selection:: By job programming

Connection:: 3-phase, 3-phase +N, 2 phase L1 or A and L3 or C (2 W-meter-method) 7 pole connector

Input ranges II L1 or A, L2 or B, L3 or C, N:: 0.5 V nominal (for II) 1.4 Vpeak

Intrinsic uncertainty:: 0.3 % of II

Max. overload:: 10 V ac

Input resistance:: App. 8.2 kO

Current transformer:: Ratio O 999 kA / II

Power systems: Delta, 2-Element Delta, Wye, Single Phase, Split Single Phase

Reviews

Accessories

Loading Accessories

Reviews

Fluke 1744 Customer Reviews

0 Reviews
5 stars
 (0)
4 stars
 (0)
3 stars
 (0)
2 stars
 (0)
1 star
 (0)
 
 
 
 
 
Average Customer Review
         
0 reviews
0 customer reviews
Share your thoughts with other customers
Create your own review
No reviews found to display for this rating.

Fluke Price List

FREE Fluke webinar on planned maintenance this November
Hioki Clampon HiTester
X


secured website

Interworld Highway, LLC dba TEquipment.NET

205 Westwood Avenue. Long Branch, NJ 07740

Privacy Policy | Terms and Conditions | Site Map

Copyright© 2016 Interworld Highway, LLC

secured website
We Price Match!

Give our sales team a call at 877.571.7901 (Toll Free) or 732.222.7077 (International) and we'll match any competitor's price.

X