Fluke 4180-156 Precision Infrared Calibrator

 
Fluke 4180-156
Catalog #: 3109516
         
0 reviews
IR CALIBRATOR,152 MM (6IN), -15 TO 120C,115V
Free Gift From Fluke With Purchase

Features

  • Calibrated radiometrically for meaningful, consistent results.
  • Accredited calibration included
  • Accurate, reliable performance from –15 °C to 500 °C
  • Large 152 mm (6 in) target captures peripheral vision of IR thermometer for more accurate measurements
  • Light weight and convenient handle make it easy to transport
  • Intuitive, easy-to-read display that indicates when temperature is stable.
  • Reaches temperature set-point fast for ef?cient ?eld operation
  • Guaranteed accuracy speci?cations
  • Radiometric calibration included for traceable best practice results
  • Excellent stability and uniformity
Loading Prices
Sale: $8,665.00
  + Free shipping over $99

Marketing-Promo-Add-to-Cart-176x92-3-items

Loading Callouts
0% APR Financing Available - Eligibility Subject to Applicant's Creditwothiness
Questions?
Ask Our Factory
Trained Engineers
• 877.571.7901
Loading Series Compare

Compare Products in this Series

Product Name Style (Infrared Calibrators) Max Temperature Accuracy Availability Price
4180-156
4180-156
IR CALIBRATOR,152 MM (6IN), -15 TO 120C,115V
Bench Top 500 C ± 0.40 °C at –15 °C ± 0.40 °C at 0 °C ± 0.50 °C at 50 °C ± 0.50 °C at 100 °C ± 0.55 °C at 120 °C Edu Price Standard Price Gov't Price
4181-156
4181-156
IR CALIBRATOR, 152 MM (6IN), 35 TO 500C,115V
Bench Top 500 C ± 0.35 °C at 35 °C ± 0.50 °C at 100 °C ± 0.70 °C at 200 °C ± 1.20 °C at 350 °C ± 1.60 °C at 500 °C Edu Price Standard Price Gov't Price
4180-156

Fluke 4180-156 Precision Infrared Calibrator

         
0 reviews
  Add to cart

Product Information

4180-156 IR Calibrator, 152 mm (6 in), –15 °C to 120 °C

Accuracy and traceability for infrared measurements
Now it’s easy to increase your IR temperature measurement accuracy with the new 4180/ 81 Precision Infrared Calibrators from Fluke Calibration. These infrared temperature calibrators give more consistent, accurate and reliable calibrations because emissivity is radiometrically calibrated, and the target size minimizes size of source effect errors. In addition, these infrared calibrators simplify calibration because they uniquely compensate for errors caused by thermometer emissivity settings.

The 4180 Series of Precision Infrared Calibrators for infrared thermometers and thermal imagers is fast, accurate, and easy to use. It comes with an accredited calibration from one of the world’s most trusted temperature calibration laboratories, sample calibration procedures for Fluke thermometers built right in and everything you need to get started making high-quality infrared thermometer calibrations. This is the perfect solution for any infrared thermometer or thermal imager within its temperature range.

The 4180 Infrared Temperature Calibrator reaches temperatures from –15 °C to 120 °C and the 4181 Infrared Temperature Calibrator has a temperature range from 35 °C to 500 °C. Uniformity is important in infrared temperature calibration work because an infrared thermometer will “see” as much as the entire target when placed at the appropriate calibration distance.

In addition, with accuracies as good as ± 0.35 °C the 4180 Series can meet its specifications without additional emissivity-related corrections, leading to legitimate test uncertainty ratios (TUR) as good as 4:1.

Emissivity, blackbodies and graybodies
Most people associate a blackbody calibration source with calibrating infrared thermometers. Although the word blackbody specifically refers to an ideal surface that emits and absorbs electromagnetic radiation with the maximum amount of power possible at a given temperature, many calibrators with non-ideal surfaces are also referred to as "blackbody calibrators." While an ideal surface would have an emissivity equal to 1.00, many of these "blackbody calibrators" have an emissivity of approximately 0.95 (better described as a “graybody”). A true blackbody calibration source would usually be a long cavity with a narrow opening. Unfortunately the opening is usually too narrow to be useful for calibrating common infrared thermometers which require a large target size for an accurate calibration. The advantage of a true blackbody calibration source is that the emissivity is precisely known. Whereas traditional flat plate calibrators have emissivities with uncertainties too large for meaningful calibrations of most thermometers. That is why the 418X Precision Infrared Thermometers are radiometrically calibrated to correct for uncertainties caused by emissivity and heat loss at the surface of the "blackbody" calibration source.

What's In The Box

  • 4180 IR Calibrator
  • Report of Calibration (NVLAP Accredited)
  • Power Cord
  • User’s Guide
  • Getting Started Guide
  • Documentation CD
  • Target Cover
  • Serial Cable

Specifications

Specifications
  4180 4181
Temperature range (@ 23 °C ambient, 0.95 emissivity) –15 °C to 120 °C 35 °C to 500 °C
Display accuracy1 ± 0.40 °C at –15 °C
± 0.40 °C at 0 °C
± 0.50 °C at 50 °C
± 0.50 °C at 100 °C
± 0.55 °C at 120 °C
± 0.35 °C at 35 °C
± 0.50 °C at 100 °C
± 0.70 °C at 200 °C
± 1.20 °C at 350 °C
± 1.60 °C at 500 °C
Stability ± 0.10 °C at –15 °C
± 0.05 °C at 0 °C
± 0.10 °C at 120 °C
± 0.05 °C at 35 °C
± 0.20 °C at 200 °C
± 0.40 °C at 500 °C
Uniformity (5.0 in dia of center of target)2 ± 0.15 °C at –15 °C
± 0.10 °C at 0 °C
± 0.25 °C at 120 °C
± 0.10 °C at 35 °C
± 0.50 °C at 250 °C
± 1.00 °C at 500 °C
Uniformity (2.0 in dia of center of target)2 ± 0.10 °C at -15 °C
± 0.10 °C at 0 °C
± 0.20 °C at 120 °C
± 0.10 °C at 35 °C
± 0.25 °C at 250 °C
± 0.50 °C at 500 °C
Heating time 15 min: –15 °C to 120 °C
14 min: 23 °C to 120 °C
20 min: 35 °C to 500 °C
Cooling time 15 min: 120 °C to 23 °C
20 min: 23 °C to –15 °C
100 min: 500 °C to 35 °C
40 min: 500 °C to 100 °C
Stabilization time 10 minutes
Nominal emissivity3 0.95
Thermometer emissivity compensation 0.9 to 1.0
Target diameter 0152.4 mm (6 in)
Computer interface RS-232
Power 15 V ac (± 10%), 6.3 A,
50/60 Hz, 630 W
230 V ac (± 10%), 3.15 A,
50/60 Hz, 630 W
115 V ac (± 10%), 10 A,
50/60 Hz, 1000 W
230 V ac (± 10%), 5 A,
50/60 Hz, 1000 W
Fuse(s) 115 V ac 6.3 A, 250 V, slow blow
230 V ac 3.15 A, 250 V, T
115 V ac 10 A, 250 V, fast blow
230 V ac 5 A, 250 V, F
Size (HxWxD) 356 mm x 241 mm x 216 mm
(14 in x 9.5 in x 8.5 in)
356 mm x 241 mm x 216 mm
(14 in x 9.5 in x 8.5 in)
Weight 9.1 kg (20 lb) 9.5 kg (21 lb)
Safety EN 61010-1:2001, CAN/CSA C22.2 No. 61010.1-04
1For 8 µm to 14 µm spectral band thermometers with emissivity set between 0.9 and 1.0
2The uniformity specification refers to how IR thermometers with different spot sizes both focused at the center of the targer will measure the same temperature.
3The target has a nominal emissivity of 0.95, however it is radiometrically calibrated to minimize emissivity related uncertainties.

Fluke 4180-156 Product Specifications Summary:
(for full specs please see the full specs tab or the data sheet)

Process / Calibration/Temperature Calibration/Infrared Calibrators / Blackbodies Template

Style (Infrared Calibrators)Bench Top
Max Temperature500 C
Accuracy± 0.40 °C at –15 °C

± 0.40 °C at 0 °C

± 0.50 °C at 50 °C

± 0.50 °C at 100 °C

± 0.55 °C at 120 °C
StabilitySee note 
Stabilization Time10 MIN
Digital Display (Infrared Calibrators)Yes
RTD Reference TemperatureYes
Fixed EmissivityYes 
Spot Diameter6 IN (25.40 MM)
Heating Time15 MIN 
Cooling Time20 MIN 
ProgrammableYes

Test Equipment General Attributes

Unique FeaturesRapid heating and cooling

RS-232 interface capability

Temperature scan rate control

Eight set-point memory

Adjustable readout in °C or °F

Adjustable Emissivity
Warranty1 YEARS
Calibration IncludedFactory Calibration
Power Supply Voltage120V/220V Universal
Safety ApprovalCSA 
Data Logging What's This?No
Interfaces I/O Analog Output, IR, RS-232, Analog Input
Product Weight20 LBS
Product Height14 IN
Product Length8.5 IN
Product Width9.5 IN
Shipping Weight26.5 LBS
Country of OriginUnited States
Shipping Height18.9 IN
Shipping Length18.9 IN
Shipping Width18.9 IN
UPC095969441087

Reviews

Accessories

Loading Accessories

Reviews

Fluke 4180-156 Customer Reviews

0 Reviews
5 stars
 (0)
4 stars
 (0)
3 stars
 (0)
2 stars
 (0)
1 star
 (0)
 
 
 
 
 
Average Customer Review
         
0 reviews
0 customer reviews
Share your thoughts with other customers
Create your own review
No reviews found to display for this rating.

Fluke Price List

X


secured website

Interworld Highway, LLC dba TEquipment.NET

205 Westwood Avenue. Long Branch, NJ 07740

Privacy Policy | Terms and Conditions | Site Map

Copyright© 2016 Interworld Highway, LLC

secured website
We Price Match!

Give our sales team a call at 877.571.7901 (Toll Free) or 732.222.7077 (International) and we'll match any competitor's price.

X