Fluke 5609-9BND-L Probe, Secondary PRT, 100 ohm, 9 inch 90 Degree Bend

 
Fluke 5609-9BND-L
Catalog #: 3116081
         
0 reviews
PROBE, SECON. PRT, 100 OHM,9IN 90 DEG BEND
Free Gift From Fluke With Purchase

Features

  • 5609-9BND-L Probe, Secondary PRT, 100 ohm, 9 inch 90 Degree Bend
  • –200 °C to 670 °C  (100 mm minimum immersion)
  • ± 0.01 short-term stability
  • Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0
  • Dry-well reference with 90 ° bend
Loading Prices
Sale: $1,135.00
  + Free shipping over $99

Loading Callouts
Questions?
Ask Our Factory
Trained Engineers
M-F 8AM - 9PM EST
• 877.571.7901

Compare Products in this Series

Product Name Application/Properties Max Temperature Min Temperature Availability Price
5609-9BND-L
5609-9BND-L
PROBE, SECON. PRT, 100 OHM,9IN 90 DEG BEND
Immersion 670 C -200 F
5609-9BND-A
5609-9BND-A
PROBE, SECON. PRT, 100 OHM,9IN 90 DEG BEND
Immersion 670 C -200 F
5609-9BND-B
5609-9BND-B
PROBE, SECON. PRT, 100 OHM,9IN 90 DEG BEND
Immersion 670 C -200 F
5609-9BND-D
5609-9BND-D
PROBE, SECON. PRT, 100 OHM,9IN 90 DEG BEND
Immersion 670 C -200 F
5609-9BND-J
5609-9BND-J
PROBE, SECON. PRT, 100 OHM,9IN 90 DEG BEND
Immersion 670 C -200 F
5609-9BND-M
5609-9BND-M
PROBE, SECON. PRT, 100 OHM,9IN 90 DEG BEND
Immersion 670 C -200 F
5609-9BND-P
5609-9BND-P
PROBE, SECON. PRT, 100 OHM,9IN 90 DEG BEND
Immersion 670 C -200 F
Fluke 5608/5609 Secondary PRTs with Calibration Options

Fluke 5609-9BND-L Probe, Secondary PRT, 100 ohm, 9 inch 90 Degree Bend

         
0 reviews
  Add to cart

Product Information

Fluke 5609-9BND-L Probe, Secondary PRT, 100 ohm, 9 inch 90 Degree Bend.
The 5608 comes with a one-eighth inch (3.18 mm) diameter sheath in lengths of 9 inches or 12 inches. The 5609 comes with a one-quarter inch (6.35 mm) diameter sheath in lengths of 12 inches, 15 inches, and 20 inches; or with a 6 mm diameter in lengths of 300 mm, 400 mm, or 500 mm.

When looking for improved response time and reduced stem effect in shallow immersion, look for small diameter probes, because the measurement error called stem effect is caused by the diameter of the stem rather than the length of the stem.

Both of these probes have Inconel™ sheaths and are made using a special manufacturing process, giving them great precision over a wide temperature range. The sensors for these probes are reference-grade platinum and feature four-wire connections with less noisy measurements than two-wire counterparts.

These probes come with a certificate of compliance to ensure the meet their specifications. If you’d like, you can also order a NVLAP-accredited calibration from our laboratory, lab code 200348-0. On the report of calibration, you’ll get the test data and the ITS90 calibration coefficients that you can easily input into any Fluke Calibration thermometer. If you order your probe with an smart connector, we’ll program the coefficients directly into your connector, which loads the coefficients for you when you plug it into our 1524 Handheld Thermometer.

Specifications

Fluke 5608/5609 Specification
Temperature range 5608: –200 °C to 500 °C
5609: –200 °C to 670 °C
Nominal resistance at 0.01 °C 100 Ω ± 0.5 Ω
Temperature coefficient 0.0039250 Ω/Ω/°C
Relative Accuracy[1] ± 0.007 °C at –200 °C
± 0.008 °C at 0 °C
± 0.020 °C at 420 °C
± 0.027 °C at 660 °C
Short-term repeatability[2] ± 0.007 °C at 0.010 °C
± 0.013 °C at max temp
Drift[3] ± 0.01 °C at 0.010 °C
± 0.02 °C at max temp
Hysteresis ± 0.01 °C maximum
Sensor length 30 mm ± 5 mm (1.2 in ± 0.2 in)
Sensor location 3 mm ± 1 mm from tip (0.1 in ± 0.1 in)
Sheath material Inconel™ 600
Minimum insulation resistance 5608: 500 MΩ at 23 °C, 20 MΩ at 500 °C
5609: 500 MΩ at 23 °C, 10 MΩ at 670 °C
Transition junction
temperature range[4]
–50 ºC to 200 °C
Transition junction dimensions 71 mm x 12.5 mm (2.8 in x 0.49 in)
Minimum immersion length[5]
(<5 mK error)
5608: 80 mm (3.1 in)
5609: 100 mm (3.9 in)
Maximum immersion length 305 mm (12 in)
Response time[5] 5608: 9 seconds typical
5609: 12 seconds typical
Self heating (in 0 °C bath) 5608: 75 mW/°C
5609: 50 mW/°C
Lead-wire cable type PTFE 24 AWG
Lead-wire length 1.8 m (6 ft)
Lead-wire temperature range –50 °C to 250 °C
Calibration Calibration not included; NVLAP-accredited calibration optional, lab
code 200348-0. Please see calibration uncertainty table and its
explanation of changeable uncertainties.
[1] Includes short-term
repeatability and 100 hr drift.
Calibration will add additional
uncertainties.

[2] Three thermal cycles from min
to max temp, includes hysteresis,
95 % confidence (k=2)

[3]After 100 hours at max temp,
95 % confidence (k=2)

[4] Temperatures outside this
range will cause irreparable
damage. For best performance,
transition junction should not be
too hot to touch.

[5] Per ASTM E 644
Calibration Uncertainty for optional NVLAP-accredited†
calibration
Temperature range Expanded Uncertainty (k=2)
–200 °C 0.025 °C
–100 °C 0.025 °C
–40 °C 0.025 °C
0 °C 0.025 °C
156 °C 0.025 °C
230 °C 0.030 °C
420 °C 0.045 °C
660 °C 0.050 °C
Note: Calibration uncertainties depend on the uncertainties of
the lab performing the calibration. Subsequent calibrations of
this probe performed with different processes, at different
facilities, or with changed uncertainty statements may state
different uncertainties. †Lab code 200348-0

Fluke 5609-9BND-L Product Specifications Summary:
(for full specs please see the full specs tab or the data sheet)

Accessories/Probes/Temperature Probes Template

Application/PropertiesImmersion
Max Temperature670 C
Min Temperature-200 F
Wire TerminationOther 
Insulation MaterialTeflon
Probe Length9 IN 
Lead Length72 IN (25.40 MM)

Test Equipment General Attributes

Unique FeaturesNominal resistance at 0.01 °C: 100 Ω ± 0.5 ΩTemperature coefficient: 0.0039250 Ω/Ω/°C

Short-term repeatability: ± 0.01 °C at 0.010 °C

± 0.02 °C at max temp

Drift: ± 0.01 °C at 0.010 °C

± 0.02 °C at max temp

Hysteresis: ± 0.01 °C maximum

Sensor length: 30 mm ± 5 mm (1.2 in ± 0.2 in)

Sensor location: 3 mm ± 1 mm from tip (0.1 in ± 0.1 in)

Sheath material: Inconel™ 600

Minimum insulation resistance: 500 MΩ at 23 °C, 10 MΩ at 670 °C

Transition junction dimensions: 71 mm x 12.5 mm (2.8 in x 0.49 in)

Minimum immersion length (<5 mK error):

100 mm (3.9 in)

Maximum immersion length: 305 mm (12 in)

Response time: 12 seconds typical

Self heating (in 0 °C bath): 50 mW/°C

Lead-wire temperature range: -50 °C to 250 °C
Warranty1 YEARS
Calibration IncludedNone 
Data Logging What's This?No
Interfaces I/O Other
Product Weight5.95 LBS
Product Height7.87 IN
Product Length24.02 IN
Product Width12.2 IN
Shipping Weight6.55 LBS
ECCN Number3A992
Country of OriginChina
Shipping Height9.84 IN
Shipping Length24.02 IN
Shipping Width12.2 IN
UPC095969441612

Reviews

Accessories

Loading Accessories

Reviews

Fluke 5609-9BND-L Customer Reviews

0 Reviews
5 stars
 (0)
4 stars
 (0)
3 stars
 (0)
2 stars
 (0)
1 star
 (0)
 
 
 
 
 
Average Customer Review
         
0 reviews
0 customer reviews
Share your thoughts with other customers
Create your own review
No reviews found to display for this rating.

Fluke Price List

Fluke Accessories
X


secured website

Interworld Highway, LLC dba TEquipment.NET

205 Westwood Avenue. Long Branch, NJ 07740

Privacy Policy | Terms and Conditions | Site Map

Copyright© 2016 Interworld Highway, LLC

secured website
We Price Match!

Give our sales team a call at 877.571.7901 (Toll Free) or 732.222.7077 (International) and we'll match any competitor's price.

X