Fluke 5608-12-S Probe with Calibration Options

 
Fluke 5608-12-S
Catalog #: 3057118
         
0 reviews
PROBE, SECON. PRT, 100 OHM (1/8 X 12 INCH)

Features

  • Spade lug connectors tips
  • Probe size: 12 in by 1/8 in
  • 200 °C to 500 °C (80mm minimum immersion)
  • +/- 0.01 short-term stability
  • Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0
  • The 5608 comes with a one-eighth inch (3.18mm) diameter sheath in lengths of 12 inches
Loading Prices
List Price: $710.00
Sale: $639.00
Loading Callouts
Questions?
Ask Our Factory
Trained Engineers
M-F 8AM - 9PM EST
• 877.571.7901

Compare Products in this Series

Product Name Application/Properties Max Temperature Min Temperature Availability Price
5608-12-S
5608-12-S
PROBE, SECON. PRT, 100 OHM (1/8 X 12 INCH)
5608-12-P
5608-12-P
PROBE, SECON. PRT, 100 OHM (1/8 X 12 INCH)
Immersion 500 C -200 F
5608-12-J
5608-12-J
PROBE, SECON. PRT, 100 OHM (1/8 X 12 INCH)
Immersion 500 C -200 F
5608-12-D
5608-12-D
PROBE, SECON. PRT, 100 OHM (1/8 X 12 INCH)
Immersion 500 C -200 F
5608-12-M
5608-12-M
PROBE, SECON. PRT, 100 OHM (1/8 X 12 INCH)
Immersion 500 C -200 F
5608-12-L
5608-12-L
PROBE, SECON. PRT, 100 OHM (1/8 X 12 INCH)
Immersion 500 C -200 F
5608-12-B
5608-12-B
PROBE, SECON. PRT, 100 OHM (1/8 x 12 INCH)
Immersion 500 C -200 F
5608-12-A
5608-12-A
PROBE, SECON. PRT, 100 OHM (1/8 X 12 INCH)
5608-9-S
5608-9-S
PROBE, SECON. PRT, 100 OHM (1/8 X 9 INCH)
5608-12-G
5608-12-G
PROBE, SECON. PRT, 100 OHM (1/8 X 12 INCH)
5608-9-G
5608-9-G
PROBE, SECON. PRT, 100 OHM (1/8 X 9 INCH)
Fluke Secondary PRTs with Calibration Options

Fluke 5608-12-S Probe with Calibration Options

         
0 reviews
  Add to cart

Product Information

Secondary PRT Probe with Calibration Option, 12 in x 1/8 in, Spade Lugs

If you want a very stable thermometer and are particular about the calibration, then look no further than Fluke Calibration 5608-12-S Secondary PRT Probe with Calibration Option, and Spade Lugs. Its short-term stability at the triple point of water is only +/-10 mK and its one-eighth inch (3.18 mm) diameter gets you accurate measurements from -200 °C to 500 °C with only 80 mm (3.1 in) of immersion. This probe has Inconel sheath and is made using a special manufacturing process, giving it great precision over a wide temperature range. The sensor for this probes is reference-grade platinum and feature four-wire connections with less noisy measurements than two-wire counterparts.

Specifications

Specifications
Temperature range 5608: –200 °C to 500 °C 5609: –200 °C to 670 °C
Nominal resistance at 0.01 °C 100 Ω ± 0.5 Ω
Temperature coefficient 0.0039250 Ω/Ω/°C
Relative Accuracy[1] ± 0.007 °C at –200 °C
± 0.008 °C at 0 °C
± 0.020 °C at 420 °C
± 0.027 °C at 660 °C
Short-term repeatability[2] ± 0.007 °C at 0.010 °C
± 0.013 °C at max temp
Drift[3] ± 0.01 °C at 0.010 °C
± 0.02 °C at max temp
Hysteresis ± 0.01 °C maximum
Sensor length 30 mm ± 5 mm (1.2 in ± 0.2 in)
Sensor location 3 mm ± 1 mm from tip (0.1 in ± 0.1 in)
Sheath material Inconel™ 600
Minimum insulation resistance 5608: 500 MΩ at 23 °C, 20 MΩ at 500 °C
5609: 500 MΩ at 23 °C, 10 MΩ at 670 °C
Transition junction temperature range[4] –50 °C to 200 °C
Transition junction dimensions 71 mm x 12.5 mm (2.8 in x 0.49 in)

Minimum immersion length[5]     (<5 mK error)

5608: 80 mm (3.1 in)
5609: 100 mm (3.9 in)
Maximum immersion length 305 mm (12 in)
Response time[5] 5608: 9 seconds typical
5609: 12 seconds typical
Self heating (in 0 °C bath) 5608: 75 mW/°C
5609: 50 mW/°C
Lead-wire cable type PTFE 24 AWG
Lead-wire length 1.8 m (6 ft)
Lead-wire temperature range –50 °C to 250 °C
Calibration

Calibration not included; NVLAP-accredited calibration optional, lab code 200348-0. Please see calibration uncertainty table and its explanation of changeable uncertainties.

[1] Includes short-term repeatability and 100 hr drift. Calibration will add additional uncertainties.

[2] Three thermal cycles from min to max temp, includes hysteresis, 95 % confidence (k=2)

[3] After 100 hours at max temp, 95 % confidence (k=2)

[4] Temperatures outside this range will cause irreparable damage. For best performance, transition junction should not be too hot to touch.

[5] Per ASTM E 644
Calibration Uncertainty for optional NVLAP-accredited† calibration
Temperature Expanded Uncertainty (k=2)
–200 °C 0.025 °C
–100 °C 0.025 °C
–40 °C 0.025 °C
0 °C 0.025 °C
156 °C 0.025 °C
230 °C 0.030 °C
420 °C 0.045 °C
660 °C 0.050 °C
Note: Calibration uncertainties depend on the uncertainties of the lab performing the calibration. Subsequent calibrations of this probe performed with different processes, at different facilities, or with changed uncertainty statements may state different uncertainties. †Lab code 200348-0

Fluke 5608-12-S Product Specifications Summary:
(for full specs please see the full specs tab or the data sheet)

Test Equipment General Attributes

Country of OriginChina

Reviews

Reviews

Fluke 5608-12-S Customer Reviews

0 Reviews
5 stars
 (0)
4 stars
 (0)
3 stars
 (0)
2 stars
 (0)
1 star
 (0)
 
 
 
 
 
Average Customer Review
         
0 reviews
0 customer reviews
Share your thoughts with other customers
Create your own review
No reviews found to display for this rating.

Fluke Price List

Fluke Accessories
X


secured website

Interworld Highway, LLC dba TEquipment.NET

205 Westwood Avenue. Long Branch, NJ 07740

Privacy Policy | Terms and Conditions | Site Map

Copyright© 2016 Interworld Highway, LLC

secured website
We Price Match!

Give our sales team a call at 877.571.7901 (Toll Free) or 732.222.7077 (International) and we'll match any competitor's price.

X