POWER QUALITY ANALYZER, USA Factory reconditioned - Full factory warranty
Free Gift From Fluke With Purchase

Features

  • Factory reconditioned - Full factory warranty
  • New! NiMH Battery provides extended operating time of 6.5 hours
  • Combines the most useful capabilities of a power quality analyzer, multimeter and scope
  • Calculates 3-phase power on balanced loads, from a single-phase measurement
  • Trends voltage, current, frequency, power harmonics and captures voltage sags, transients and inrush current
  • Monitoring functions help track intermittent problems and power system performance
  • Records two selectable parameters for up to 16 days
  • 20 measurement memories to save/recall screens and data with cursor readings
  • FlukeView software can log harmonics and all other readings over time and provides a complete harmonics profile up to the 51st harmonic
  • Measures resistance, diode voltage drop, continuity, and capacitance
  • Users/applications manual and power quality video to help answer tough questions
  • Complete package with voltage probes and 400 A current clamp, FlukeView Software and optically isolated interface cable
  • 3 year warranty on the Fluke 43B, 1 year on accessories
Loading Prices
Sale: $3,499.99
  + Free shipping over $99

FREE BORESCOPE
WITH PURCHASE


Loading Callouts
0% APR Financing Available - Eligibility Subject to Applicant's Creditwothiness
Questions?
Ask Our Factory
Trained Engineers
• 877.571.7901
Loading Series Compare
Fluke 43B/003-Refurb Power Quality Analyzer

Fluke 43B/003-Refurb Quality Analyzer Power

         
0 reviews
  Add to cart

Product Information

Fluke 43B/003-Refurb Power Quality Analyzer

 
Fluke_43B-003-Refurb_tn

Power Quality Analyzer

×
 
  • Calculates 3-phase power on balanced loads, from a single-phase measurement

  • Trends Voltage, current, frequency, power harmonics and captures Voltage sags, transients and inrush current

  • Monitoring Functions help track Intermittent problems and power system performance

The Fluke 43B/003-Refurb Power Quality Analyzer performs the measurements you need to maintain power systems, troubleshoot power problems and diagnose equipment failures. All in a rugged handheld package.
   

 

  Carrying Case Contents
 
1. Fluke 43B Power Quality Analyzer
2. BP120MH Ni-MH Battery Pack (installed)
3. PM8907/8xx Power Adapter/Battery Charger
4. TL24 Test Leads, red and black
5. TP1 Flat blade Test Pins, red and black
6. TP4 4mm Test Pins, red and black
7. AC85A Large Jaw Alligator Clips for Banana Plugs, red and black
8. AC20 Industrial Alligator Clips for Banana Plugs, red and black
9. i400s Clamp-on AC Current Probe
10. BB120 Shielded Banana-to-BNC Adapter Plugs (1x black)
11. Getting Started Manual incl. User / Application Manual CD
12. OC4USB Optically Isolated USB Adapter/Cable
13. SW43W FlukeView ® Power Quality Analyzer software
14.0C120 Hard Carrying Case

What's In The Box

  • C120 Hard Case
  • Test Leads
  • Industrial Test Clips
  • Large Jaw Alligator Clips
  • TP1 Flat-tipped Slim-Reach Test Probes
  • TP4 4 mm Round Slim-Reac Test Probes
  • i400s 400 A AC Current Clamp
  • OC4USB Optically Isolated USB Interface Adapter
  • BP120MH Rechargeable NiMH Battery Pack (installed)
  • PM 8907 Line Voltage Adapter/Battery Charger
  • SW43W FlukeView Power Quality Analyzer Software for Windows
  • Power Quality CD with:
    • User’s manual
    • Power quality video
    • Application guide
  • Shielded Banana-to-BNC Adapter
  • Users Manual / Application Guide
Maintain power systems, troubleshoot power
problems, diagnose equipment failures
The Fluke 43B Power Quality Analyzer performs
the measurements you need to maintain power
systems, troubleshoot power problems and
diagnose equipment failures. All in a rugged
handheld package.
• New! NiMH Battery provides extended
operating time of 6.5 hours
• Combines the most useful capabilities of a
power quality analyzer, multimeter and scope
• Calculates 3-phase power on balanced loads,
from a single-phase measurement
• Trends voltage, current, frequency, power
harmonics and captures voltage sags,
transients and inrush current
• Monitoring functions help track intermittent
problems and power system performance
• Records two selectable parameters for up
to 16 days
• 20 measurement memories to save/recall
screens and data with cursor readings
• FlukeView® Software can log harmonics
and all other readings over time and provides
a complete harmonics profile up to the
51st harmonic
• Measures resistance, diode voltage drop,
continuity, and capacitance
• Users/applications manual and power quality
video to help answer tough questions
• Complete package with voltage probes and
400 A current clamp, FlukeView Software and
optically isolated interface cable
• 3 year warranty on the Fluke 43B, 1 year on
accessories
• On screen graphics show you how to set up
3-phase power measurements
• Watts, power factor, displacement power
factor (Cos f), VA and VAR
• Voltage and current waveforms
• Voltage, current, and power harmonics
• Up to 51st harmonic
• Total harmonic distortion (THD)
• Phase angle of individual harmonics
• Voltage and current waveforms
• True-rms voltage and current
• Frequency
Fluke 43B Power Quality Analyzer
Input Characteristics Ranges Accuracy
Input impedance 1 M½, 20 pF
Voltage rating 600 Vrms, CAT III
Volt/Amps/Hertz
True-rms voltage (AC+DC) 5.000 V, 50.00 V, 500.0 V, 1250 V* ± (1 % + 10 counts)
True-rms current (AC+DC) 50.00 A, 500.0 A, 5.000 kA, 50.00 kA, 1250 kA ± (1 % + 10 counts)
Frequency 10.0 Hz to 15.0 kHz ± (0.5 % + 2 counts)
CF Crest Factor 1.0 to 10.0 ± (5 % + 1 count)
Power
W, VA, VAR Reactive Power 250 W 2.50 kW, 25.0 kW, 250kW, 2.50 MW, ± (2 % + 6 counts) Total Power
1-phase and 3-phase, 3 25 MW, 250 MW, 625 MW, 1.56 GW ± (4 % + 4 counts) Fundamental
conductor balanced loads Power
PF Power Factor 0.00 to 1.00 ± 0.04
DPF Displacement Power Factor 0.00 to 0.25 not specified
0.25 to 0.90 ± 0.04
0.90 to 1.00 ± 0.03
Hz Frequency fundamental 40.0 to 70.0 Hz ± (0.5 % + 2 counts)
Harmonics
Volts, Amps, Watts Fundamental V, A ± (3 % + 2 counts),
W ± (5 % + 2 counts)
2 to 31st Harmonic V, A ± (5 % + 3 counts),
W ± (10 % + 10 counts)
32 to 51st Harmonic V, A ± (15 % + 5 counts),
W ± (30 % + 5 counts)
Frequency of fundamental 40 Hz to 70 Hz ± 0.25 Hz
Phase Volt & Amps (between Fund. & Harmonic) 2nd (± 3°) … 51st (± 15°)
Watts (between Volt Fund. & Amps
Harmonic ) Fund (± 5°) … 51st (± 15°)
K-Factor (Amps & Watts) 1.0 to 30.0 ± 10 %
THD 0.00 to 99.99 ± (3% + 8 counts)
Sags & Swells
Recording times (selectable) 4 min to 16 days
Vrms actual, Vrms max, 5.000 V, 50.00 V 500.0 V, 1250 V* Readings ± (2 % +10 counts)
min (AC + DC) Cursor readings ± (2 % + 12 counts)
Cursor Readings Average ± (2 %
+10 counts)
Arms actual, Arms max, 50.00 A, 500.0 A, 5.000 kA, 50,00 kA
min (AC + DC)
Recording
Recording times (selectable) 4 min to 16 days
Parameters Choose one or two parameters from one of the groups below
V/A/Hz Line Voltage, Current, Frequency
Power Watts, VA, VAR, PF, DPF, Frequency
Harmonics THD, Volts (Fund. & Harmonic), Amps(F&H) Watts(F&H) Freq.(H), %(H) of total, Phase(H), KF
Ohms Ohms, Diode, Continuity, Capacitance
Temperature °C or °F
Scope DC Voltage, DC Current, AC Voltage, AC Current, Frequency, Pulse Width + or -,
Phase, Duty cycle + or -, Peak max, Peak min, Peak min-max, Crest Factor
Transients
Minimum pulse width 40 ns
Useful bandwidth input DC to 1 MHz (with test leads TL24)
Number of transients 40
Voltage threshold settings 20 %, 50 %, 100 %, 200 % above or below reference signal
Reference signal After START, the Vrms and frequency of the signal are measured. From these
data a pure sinewave is calculated as reference for threshold setting.
Vpeak min, Vpeak max at cursor 10 V, 25 V, 50 V, 125 V, 250 V, 500 V, 1250 V ± 5 % of full scale
*Rated 600 V CAT II
Specifications
Accuracies are stated as ± (percentage of
reading + counts) without probes unless
otherwise noted.
Specifications are valid for signals with a
fundamental between 40 and 70 Hz.
• Measurements are always automatically
recorded to instantly show changes over time
• Use cursors to read time and date of sags
and swells
• Catch voltage transients and waveform
distortion down to 40 nS
• Catch and save up to 40 transients
• Correlate the cause of transients with time
and date stamps
Inrush Current Ranges Accuracy
Current ranges (selectable) 1 A, 5 A, 10 A, 50 A, 100 A, 500 A, 1000 A
Inrush times (selectable) l s, 5 s, 10 s, 50 s, 100 s, 5 min
Cursor readings A peak max at cursor 1 and cursor 2 ± 5 % of full scale
Time between cursors** 4 to 235 pixels ± (0.2 % + 2 pixels)
Scope, dual channel scope with measurement reading
Input impedance
Input 1 1 M½/12 pF; with BB120: 20 pF ± 2 pF; with BB120 ± 3 pF
Input 2 1 M½/10 pF; with BB120: 18 pF ± 2 pF; with BB120 ± 3 pF
Vertical
Voltage ranges 50 mV/div to 500V/div ± (1% + 2 pixels)
Vertical sensitivity, resolution 5 mV/div to 500V/div, 8 bit (256 levels)
Bandwidth input 1 (voltage) DC to 20 MHz at inputs, or with VPS40 probe (Opt);
1 MHz with TL24 Leads
Bandwidth input 2 (current) DC to 15 kHz at inputs
10 kHz with 80i-500s Current Clamp
Coupling DC, AC (10Hz (-3 dB)
Horizontal
TimeBase modes Normal, roll, single
TimeBase ranges 60 s/div to 20 ns/div ± (0.4 % + 1 pixel)
Sampling rate 25 MS/s
Record length 512 per channel
(min / max samples)
Trigger source Input 1 or Input 2 or Automatic selection
Trigger mode Automatic Connect-and-View™, Free Run,
Single Shot.
Connect-and-View™ Advanced automatic triggering that recognizes signal patterns and automatically
adjusts triggering, timebase and amplitude. Automatically displays stable pictures
of complex and dynamic signals like motor drive and control signals.
Pre-trigger Up to 10 divisions
Measurement readings, Volts & Amps (DC, AC, AC + DCrms, Peak max, Peak min, Peak min / max ),
per channel selectable Frequency, Duty cycle + or - , Phase, Pulse Width + or -, Crest factor
Ohms, Diode, Continuity, Capacitance
Ohms 500.0 ½ 5.000 k½, 50.00 k½, 500.0 k½, ± (0.6 % +5 counts)
5.000 M½, 30.00 M½
Diode voltage 0 to 3.000 V ± (2 % +5 counts)
Continuity, shorts > 1 ms Beeper on at < 30 ½ ± 5 ½,
Capacitance 50.00 nF, 500.0 nF, 5.000 μF, 50.00 μF, ±(2 % +10 counts)
500.0 μF
Temperature*** -100.0 °C to 400.0 °C, ±(0.5 % +5 counts)
-200.0 °F to 800.0 °F
Max current, max open circuit volt. 0.5 mA, < 4 V (all functions above)
Memory
Number of screens 20
Optical Isolated Interface
To printer Supports HP LaserJet™, DeskJet, Epson FX/LQ and Postscript printers with
optional PAC91 Printer Adapter Cable
To PC FlukeView® Power Quality Analyzer software with PM9080 Interface
Adapter included
FlukeView® Power Quality Software
Hardware requirements PC or 100 % compatible with Windows® 95, 98, Me, 2000, NT4.0.
** 1 pixel = inrush time/250
*** Requires optional temperature accessory
• Inrush current up to 500A with supplied
current probe
• Use cursors to measure inrush current timing
• Connect-and-View™ scope for quick
waveform display
• 20MHz bandwidth with optional 10:1 voltage
probe. 15kHz on current channel with
optional current clamp
• FlukeView® Power Quality Analyzer software
(included)
• Capture measurement screens for
professional-looking reports
• Log readings to your computer disk drive
• Works with Windows word processing,
spreadsheet and analysis software
• Windows 95 / 98 / Me / 2000 / NT 4.0
Ordering Information
Fluke 43B Power Quality Analyzer
Included Accessories
C120 Hard Case
TL24 Test Leads
AC20 Industrial Test Clips
AC85 Large Jaw Alligator Clips
TP1 Flat-tipped Slim-Reach™ Test
Probes
TP4 4 mm Round Slim-Reach™
Test Probes
i400s 400 A AC Current Clamp
OC4USB Optically Isolated USB
Interface Adapter
BP120MH Rechargeable NiMH Battery
Pack (installed)
PM8907 Line Voltage Adapter/Battery
Charger
SW43W FlukeView® Power Quality
Analyzer Software for
Windows
Power Quality CD with:
• User’s manual
• Power quality video
• Application guide
Getting started guide
Shielded Banana-to-BNC adapter
Optional Accessories
C789 Soft Carrying Case
80i-110s 100A AC/DC Current Probe
i200s AC Current Clamp
i1000s 1000A AC Current Clamp
i2000flex Flexible 2000A AC Current
Probe
i3000s Clamp-On AC Current Clamp
VPS40 10:1 Voltage Probe
BB120 Two Shielded Banana-to-
BNC Adapters
80TK Thermocouple Module
80T-150U Universal Temperature Probe
PAC91 Parallel Printer Adapter
TLK225 SureGrip® Master Accessory
Test Lead Kit
TL220 63" Test Lead Set
TL221 Extension Lead Set
TL223 Electrical Test Lead Set
Power
Line voltage adapter/battery charger included
Installed battery Rechargeable NiMH pack (4.8v dc)
Operating time 4 hours
Charging time 7 hours
Environmental
Temperature 0 ºC to 50 ºC (32 ºF to 122 ºF)
Environmental MIL 28800E, Type 3, Class III, Style B
Enclosure IP51 (dust, drip water proof)
Mechanical Data
Size (H x W x D) 232 x 115 x 50 mm (9.1 x 4.5 x 2 inches)
Weight 1.1 kg (2.5 lbs.) incl. battery pack
Safety
For measurements on 600 Vrms Category III installations, Pollution Degree 2 in accordance with
EN 61010-1
ANSI/ISA S82.01-1994
CAN/CSA-C22.2 No. 61010.1-04
Surge protection 6 kV on input 1 and 2
Floating measurements 600 Vrms from any terminal to ground
Warranty 3 years parts and labor on Fluke 43B, 1 year on accessories
General Specifications
43B POWER QUALITY ANALYZER
HOLD
PRINT RUN
F1 F2 F3 ENTER
MENU RECORD
SAVE
1 2
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa (31 40) 2 675 200 or
Fax (31 40) 2 675 222
In Canada (800) 36-FLUKE or
Fax (905) 890-6866
From other countries (425) 446-5500 or
Fax (425) 446-5116
Web access: http://www.fluke.com/
©2005 Fluke Corporation. All rights reserved.
Trademarks are the property of their respective owners.
Printed in U.S.A. 11/2005 1266142 D-ENG-N Rev H
Printed on recycled paper.
Fluke.Keeping your world
up and running.

Specifications

Technical Data
Input Characteristics
Input impedance 1 MΩ, 20 pF
Voltage rating 1 MΩ, 20 pF
V/A/Hz Display
True-rms voltage (ac + dc) Ranges: 5.000 V, 50.00 V, 500.0 V, 1250 V*
Accuracy: ±(1% + 10 counts)
True-rms current (ac + dc) Ranges: 50.00 A, 500.0 A, 5.000 kA, 50.00 kA, 1250 kA
Accuracy: ±(1% + 10 counts)
Frequency Ranges: 10.0 to 15.0 kHz
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
CF Crest factor Ranges: 1.0 - 10.0
Accuracy: ±(5% + 1 count)
Power Display
Watts, VA, VAR 1-phase and 3-phase,3 conductor balanced loads
Ranges: 250 W - 1.56 GW
Accuracy: ±(4% + 4 counts) Fundamental Power
± (2 % + 6 counts) Total Power
PF Power Factor Range: 20 °C to +60 °C; -4 °F to 140 °F
Reference temperature: 0 - 1.0
Accuracy: ±0.04
DPF Displacement Power Factor, Cos .F Range: 0.25 - 0.9
Accuracy: ±0.04
Range: 0.90 - 1.0
Accuracy: ±0.03
H2 Frequency Fundamental Ranges: 40.0 to 70.0 Hz
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
Harmonics Display
Voltage, Current, Frequency Ranges: Fundamental to 51st harmonic
Accuracy:  
Fundamental: VA ±(3% + 2 counts) W ±(5% + 2 counts)
2 to 31st harmonic: VA ±(5% +3 counts) W ±(10% +10 counts)
32 to 51st harmonic: VA ±(15% +5 counts) W ±(30% +5 counts)
Frequency Fundamental Ranges: 40 Hz to 70 Hz
Accuracy: ±0.25 Hz
Phase Range: V, A (between Fundamental & Harmonics)
Accuracy: ±3º to ±15º
Range: W (between Voltage Fundamental & Current Harmonics)
Accuracy: ±5º to ±15º
K-factor (Current and Power) Range: 1.0 to 30.0
Accuracy: ±10%
THD Total Harmonic Distortion Range: 0.00 - 99.99
Accuracy: ±(3% + 8 counts)
Sags and Swells
Recording times: 4 min to 16 days (selectable)
Vrms Actual, Vrms max, min(AC + DC) Ranges: 5.000V, 50.00V, 500.0V, 1250V*
Accuracy: Readings ±(2% +10 counts); Cursor readings ± (2% + 12 counts)
Arms Actual, Arms max, min (AC + DC) Ranges: 50.00A, 500.0A, 5.000 kA, 50.00 kA
Calibration interval 1 year recommended for Class-A, otherwise 2 years
Accuracy: ±(2% +10 counts)
Transient Capture
Minimum pulse width: 40 ns
Useful bandwidth input 1: DC to 1 MHz
Number of transients: 40
Voltage threshold settings: 20%, 50%, 100%, 200% above or below reference
Reference signal: After START, the Vrms and frequency of the signal are measured. From these data a pure sinewave is calculated as reference for threshold setting.
Vpeak min, Vpeak max at cursor: 10 V, 25 V, 50 V, 125 V, 250 V, 500 V, 1250 V
Accuracy: ±5% of full scale
R, C, Diode, Continuity
Resistance ranges: 500.0 Ω, 5.000 kΩ, 50.00 kΩ, 500.0 kΩ, 5.000 MΩ, 30.00 MΩ
Resistance accuracy: ±(0.6% + 5 counts)
Capacitance ranges: 50.00 nF, 500.0 nF, 5.000 µF, 50.00 µF, 500.0 µF
Capacitance accuracy: ±(2% + 10 counts)
Diode Ranges: 0 to 3.000 V
Diode voltage:  
Accuracy: ±(2% + 5 counts)
Continuity: Beeper on at < 30 O ± 5 Ω
Max current: 0.5 mA
Temperature: °C or °F
Inrush Current
Inrush times: 1 s, 5 s, 10 s, 50 s, 100 s, 5 min
Current ranges: 1 A, 5 A, 10 A, 50 A, 100 A, 500 A, 1000 A
Cursor readings: A peak max at cursor 1 and cursor 2
Accuracy: ±5% of full scale
Time between cursors: 4 to 235 pixels (1 pixel = inrush time/250) Accuracy: ±(0.2% + 2 pixels)
Temperature (with accessory)
Range: -100 °C - 400 °C
Accuracy: ±(0.5% + 5 counts)
Scope Display
Measurements: dc, ac, ac+dc, peak, peak-peak, frequency, duty cycle, phase, pulse width, crest factor
Time ranges: 20 ns/div to 60 s/div
Max sampling rate: 25 MS/s
Bandwidth Voltage channel [1]: 20 MHz at inputs, 1 MHz with TL24 Leads
Current channel [2]: DC to 15 kHz at inputs, 10 kHz with i400s Current Clamp
Coupling: AC, DC (10 Hz - 3 dB)
Vertical sensitivity: 5 mV/div to 500V/div
Vertical resolution: 8 bit (256 levels)
Record length: 512 samples per channel
Base ranges: 60 S/div to 20 nS/div ± (0.4% + 1 pixel)
Timebase modes: Normal, roll, single
Pre-trigger: Up to 10 divisions
Trigger Source: Input 1 or Input 2 or automatic selection
Trigger Mode: Automatic Connect-and-View™, Free Run, and Single Shot
Trigger Mode: Automatic Connect-and-View™, Free Run, and Single Shot
Connect-and-View: Advanced automatic triggering that recognizes signal patterns
Automatically adjusts triggering, timebase and amplitude and displays stable pictures
Memories 20 (screens, settings, data)
Memories 20 (screens, settings, data)
Recording
Recording times: 4 min to 16 days (selectable)
Parameters: Choose one or two parameters from one of the groups below:
Volts/Ampères/Hertz
Power: Watts, VA, VAR, PF, DPF, Frequency
Harmonics, THD, Volts (Fund. & Harmonic), Ampères (F&H) Watts(F&H)
Frequency (H), %(H) of total, Phase(H), KF Temperature
Resistance: Resistance, Diode, Continuity, Capacitance
Scope: DC Voltage, DC Current, AC Voltage, AC Current, Frequency, Pulse Width + or -, Phase, Duty cycle + or -, Peak max, Peak min, Peak min-max, Crest Factor
Note *Rated EN 61010-1 600 V CAT III CSA
Environmental Specifications
Operating Temperature 0°C to +50°C
Safety Specifications
Electrical Safety EN 61010-1 CAT III, 600V. CSA listed
Mechanical & General Specifications
Size 232 x 115 x 50 mm
Weight 1.1 kg
Warranty 3 years
Battery Life Rechargeable NiMH pack (charger included), 6.5 hrs extended operating time (continuous)
Shock & Vibration Mil 28800E, Type 3, Class III, Style B
Case IP51 (dust, drip, waterproof)

Fluke 43B/003-Refurb Product Specifications Summary:
(for full specs please see the full specs tab or the data sheet)

Power Measurement/Power Quality Analyzer Template

Type (Power Quality) What's This?Single Phase 
Maximum Current AC What's This?400 A 
Maximum Voltage AC1250 V
True Power / Work ( W) What's This?Yes
Apparent Power (VA) What's This?Yes
Reactive Power (VAR) What's This?Yes
Current Input Channels1
Voltage Input Channels1
Measurement Frequency (Power Quality)50 Hz, 60 Hz
Display (Power Quality)Digital, Graphical, Oscilloscope
AlarmsNo
Transient Capture What's This?Yes 
Minimum Transient Durationnano-seconds 
Displays Waveform What's This?Yes
Energy What's This?Yes
Phasor Diagrams What's This?No
Power Factor (Power Quality) What's This?Yes
Harmonics What's This?Yes
Maximum Harmonics Range51
Current Clamps IncludedYes 
Class A Compliant What's This?No
Crest FactorYes
CAT Rating What's This?III
CAT Voltage Rating (V) What's This?600V
GPS LocationNo

Test Equipment General Attributes

Unique FeaturesThe Fluke 43B Power Quality Analyzer performs
the measurements you need to maintain power
systems, troubleshoot power problems and
diagnose equipment failures. All in a rugged
handheld package.

Combines the most useful capabilities of a power quality analyzer, multimeter and scope

Calculates 3-phase power on balanced loads,
from a single-phase measurement

Trends voltage, current, frequency, power harmonics and captures voltage sags,
transients and inrush current

Monitoring functions help track intermittent
problems and power system performance

Records two selectable parameters for up
to 16 days

20 measurement memories to save/recall
screens and data with cursor readings
Warranty3 YEARS
Warranty Details3 year warranty on the Fluke 43B, 1 year on
accessories
Calibration IncludedNone
Power Supply Voltage120V 50/60 Hz
Data Logging What's This?Yes
Interfaces I/O RS-232
IP Rating What's This?IP51
Product Weight2.5 LBS
Battery TypeNimH
Product Height9.1 IN
Product Length4.5 IN
Product Width2 IN

Reviews

Accessories

Loading Accessories

Reviews

Fluke 43B/003-Refurb Customer Reviews

0 Reviews
5 stars
 (0)
4 stars
 (0)
3 stars
 (0)
2 stars
 (0)
1 star
 (0)
 
 
 
 
 
Average Customer Review
         
0 reviews
0 customer reviews
Share your thoughts with other customers
Create your own review
No reviews found to display for this rating.

Fluke Price List

Hioki Clampon HiTester
X


secured website

Interworld Highway, LLC dba TEquipment.NET

205 Westwood Avenue. Long Branch, NJ 07740

Privacy Policy | Terms and Conditions | Site Map

Copyright© 2016 Interworld Highway, LLC

secured website
We Price Match!

Give our sales team a call at 877.571.7901 (Toll Free) or 732.222.7077 (International) and we'll match any competitor's price.

X