Fluke 437-II/BASIC Power Quality Analyzer - Type (Power Quality): Single Phase, Maximum Current AC: 6000 A, Maximum Current DC: 6000 A

 
Our Customers get the best price
Free In Person Demo
Fluke 437-II/BASIC
Catalog #: 4116719
         
0 reviews
400HZ POWER QUALITY AND ENERGY ANALYZER (W/O CLAMPS)
Free Gift From Fluke With Purchase

Features

  • 400 Hz measurement: By increasing the power frequency to 400 Hz, transformers and motors can be much smaller and lighter than at 50 or 60 Hz, which is an advantage in aircrafts, submarines, space crafts, and other military equipment and hand-held tools. The 437 II model captures power quality measurements for these types of avionic and military systems.
  • Power inverter efficiency: Simultaneously measure AC output power and DC input power for power electronics systems using optional DC clamp.
  • PowerWave data capture: Capture fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.).
  • Energy loss calculator: Classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint the fiscal costs of energy losses.
  • Troubleshoot real-time: Analyze the trends using the cursors and zoom tools.
  • Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance.
  • Measure all three phases and neutral: With included four flexible current probes with enhanced thin flex design to fit into the tightest places.
  • Automatic Trending: Every measurement is always automatically recorded, without any set-up.
  • System-Monitor: Ten power quality parameters on one screen according to EN50160 power quality standard.
  • Logger function: Configure for any test condition with memory for up to 600 parameters at user defined intervals.
  • View graphs and generate reports: With included analysis software.
  • Battery life: Seven hours operating time per charge on Li-ion battery pack.
Loading Prices
Sale: $9,899.99
  + Free shipping over $99

Marketing-Promo-Add-to-Cart-176x92-3-items

Loading Callouts
0% APR Financing Available - Eligibility Subject to Applicant's Creditwothiness
Questions?
Ask Our Factory
Trained Engineers
• 877.571.7901
Loading Series Compare

Compare Products in this Series

Product Name Type (Power Quality) Maximum Current AC Maximum Current DC Availability Price
437-II/BASIC
437-II/BASIC
400HZ POWER QUALITY AND ENERGY ANALYZER (W/O CLAMPS)
3 Phase, Single Phase 6000 A 600 A Edu Price Standard Price Gov't Price
434-II
434-II
PQ AND ENERGY ANALYZER
3 Phase, Single Phase 6000 A N/A Edu Price Standard Price Gov't Price
435-II
435-II
ADVANCED PQ AND ENERGY ANALYZER
3 Phase, Single Phase 6000 A N/A Edu Price Standard Price Gov't Price
435-II/BASIC
435-II/BASIC
ADVANCED PQ AND ENERGY ANALYZER (W/O CLAMPS)
3 Phase, Single Phase 6000 A N/A Edu Price Standard Price Gov't Price
434-II/BASIC
434-II/BASIC
PQ AND ENERGY ANALYZER (W/O CLAMPS)
3 Phase, Single Phase 6000 A N/A Edu Price Standard Price Gov't Price
437-II
437-II
400HZ POWER QUALITY AND ENERGY ANALYZER
3 Phase, Single Phase 6000 A 600 A Edu Price Standard Price Gov't Price
435-II-REFURB
435-II-REFURB
ADVANCED PQ AND ENERGY ANALYZER (#4373845) Factory reconditioned - Full...
3 Phase, Single Phase 6000 A N/A
Clearance
22% OFF!
3 remain
Edu Price Standard Price Gov't Price
438-II
438-II
POWER QUALITY And MOTOR ANALYZER
3 Phase, Single Phase 6000 A 600 A Edu Price Standard Price Gov't Price
438-II/BASIC
438-II/BASIC
POWER QUALITY And MOTOR ANALYZER, W/O CLAMPS, NOFC
3 Phase, Single Phase 6000 A 600 A Edu Price Standard Price Gov't Price
na

Fluke 437-II/BASIC Power Quality Analyzer - Type (Power Quality): Single Phase, Maximum Current AC: 6000 A, Maximum Current DC: 6000 A

         
0 reviews
  Add to cart

Product Information

Locating, Predicting, Preventing and Troubleshooting Power Quality Issues – Up to 400Hz

Higher power frequencies mean smaller and lighter transformers and motors – a critical concern in avionic and military transport applications where weight is a primary concern. The Fluke 437 Series II Power Quality and Energy Analyzer is the world's only Power Quality analyzer that can monetize the cost of energy waste due to poor power quality and is ideal for characterizing power quality, conducting load studies and capturing hard-to-find voltage events over a user-defined period of time.  Designed for capturing power quality measurements in avionic and military systems, Fluke 437 Series II is the must-have 400 Hz quality analyzer.

PowerWave data capture

For some users, loads switching is a cause of power quality problems. When loads switch on, the current draw sometimes causes the voltage to drop to a level that causes other equipment to malfunction. The PowerWave function available in the 435 and 437 Series II models enables users to capture voltage, current and frequency signals simultaneously at a high speed to see which interaction is potentially causing problems. PowerWave goes beyond standard power quality measurements; PowerWave’s fast data capture mode enables system dynamics to be characterized.

Waveforms for voltage and current are continuously captured for the specified time, and are displayed on screen in high detail; the power waveform is derived from the data. In addition, half-cycle RMS values for voltage, current, power and frequency can be stored and retrieved for analysis. This feature is particularly useful for testing of standby generation systems and UPS systems where reliable switch-on can be vital.

These UPM calculations are used to quantify the fiscal cost of energy loss caused by power quality issues. The calculations are computed, along with other facility-specific information, by an Energy Loss Calculator that ultimately determines how much money a facility loses due to wasted energy.

Power inverter efficiency

Power inverters take DC current and transform it into AC current, or vice versa. Solar generation systems usually include an inverter that takes the DC energy from the solar cells and converts it to useful AC power. Inverters can lose performance over time and need to be checked. By comparing the input power with the output power you can determine the system efficiency. The 430 series II can measure the efficiency of such inverters by simultaneously measuring the DC and AC power of a system to determine how much power is lost in the conversion process.

Unified power measurement

Fluke-437-Energy-Loss

Previously, only experts could calculate how much energy was wasted due to power quality issues; utilities could calculate the cost, but the required measurement process was beyond the reach of average electricians. With the new, patented Unified Power function of the 430 Series II, you can use one handheld tool to determine how much power is being wasted, and calculate exactly what the extra consumption costs. Fluke’s patented Unified Power Measurement System provides the most comprehensive view of power available, measuring:

  • Parameters of Classical Power (Steinmetz 1897) and IEEE 1459-2000
  • Detailed Loss Analysis
  • Unbalance Analysis

Unbalance Analysis These UPM calculations are used to quantify the fiscal cost of energy loss caused by power quality issues. The calculations are computed, along with other facility-specific information by an Energy Loss Calculator that ultimately determines how much money a facility loses due to wasted energy.

AutoTrend - Quickly see the trend

Fluke-437-v-a-hz-us

Unique AutoTrend gives you fast insight into changes over time. Every displayed reading is automatically and continuously recorded without having to set up threshold levels or having to manually start the process. You can quickly view trends in voltage, current, frequency, power, harmonics or flicker on all three phases plus neutral.

SystemMonitor - Check performance against EN50160 with ease

Fluke-437-Monitor

With a single push of a button, the unique System-Monitor gives you an overview of power system performance, and checks the compliance of incoming power to EN50160 limits or to your own custom specifications. The overview is shown on a single screen, with color-coded bars clearly indicating which parameters fall outside the limits.

Fluke-437-Monitor_Events

The System-Monitor overview screen gives instant insight into whether the voltage, harmonics, flicker, frequency and the number of dips and swells fall outside the set limits. A detailed list is given of all events falling outside the set limits.

Fluke-437-435_harmonics Fluke-437-screen019 Fluke-437-435_logger
Track harmonics up to the 50th, and measure and record THD in accordance with IEC61000-4-7 requirements Measure and record power (W), VA and VARs, PF and energy consumption. Logging function allows you to customize measurement selections and provides instantaneous analysis of user-selectable parameters.

What's In The Box

  • BC430 Power Adapter
  • International plug adapter set
  • BP290 (Single capacity Li-ion battery) 28 Wh (7 hours or more)
  • TLS430 Test lead and Alligator clip set
  • WC100 color coding clips and regional decals
  • i430flex-TF, 24 inch (61 cm) length, 4 clamps
  • 8 GB SD card
  • PowerLog on CD (includes operator manuals in PDF format)
  • USB cable A-Bmini

Specifications

Product Specifications
  Model Measurement range Resolution Accuracy
Volt
Vrms (ac+dc)   1 V to 1000 V phase to neutral 0.01 V ± 0.1% of nominal voltage**** 
Vpk   1 Vpk to 1400 Vpk 1 V 5% of nominal voltage
Voltage Crest Factor (CF)   1.0 > 2.8 0.01 ± 5 %
Vfund     0.1 V ± 0.1% of nominal voltage
Amps (accuracy excluding clamp accuracy)
Amps (ac +dc) i430-Flex 1x  5 A to 6000 A 1 A ± 0.5% ± 5 counts
i430-Flex 10x 0.5 A to 600 A 0.1 A ± 0.5% ± 5 counts
1mV/A 1x 5 A to 2000 A 1A ± 0.5% ± 5 counts
1mV/A 10x 0.5 A A to 200 A (ac only) 0.1 A ± 0.5% ± 5 counts
Apk i430-Flex  8400 Apk  1 Arms ± 5 %
1mV/A 5500 Apk 1 Arms ± 5 %
A Crest Factor (CF)   1 to 10 0.01 ± 5 %
Amps½ i430-Flex 1x  5 A to 6000 A  1 A  ± 1% ± 10 counts 
i430-Flex 10x 0.5 A to 600 A 0.1 A  ± 1% ± 10 counts
1mV/A 1x   5 A to 2000 A  1A  ± 1% ± 10 counts
1mV/A 10x 0.5 A A to 200 A (ac only) 0.1 A ± 1% ± 10 counts
Afund i430-Flex 1x  5 A to 6000 A 1 A ± 0.5% ± 5 counts 
i430-Flex 10x  0.5 A to 600 A 0.1 A ± 0.5% ± 5 counts
1mV/A 1x  5 A to 2000 A 1A ± 0.5% ± 5 counts
1mV/A 10x  0.5 A A to 200 A (ac only) 0.1 A ± 0.5% ± 5 counts
Hz
Hz Fluke 437 @ 50 Hz nominal 42.500 Hz to 57.500 Hz
0.001 Hz

± 0.01 Hz
Fluke 437 @ 60 Hz nominal 51.000 Hz to 69.000 Hz
0.001 Hz

± 0.01 Hz
Fluke 437 @ 400 Hz nominal 340.0 Hz to 460.0 Hz 0.1 Hz ± 0.1 Hz
Power
Watts (VA, var) i430-Flex max 6000 MW 0.1 W to 1 MW ± 1% ± 10 counts
1 mV/A max 2000 MW 0.1 W to 1 MW ± 1% ± 10 counts
Power Factor (Cos j/DPF)   0 to 1 0.001 ± 0.1% @ nominal load conditions
Energy
kWh (kVAh, kvarh) i430-Flex 10x Depends on clamp scaling and V nominal ± 1% ± 10 counts
Energy Loss i430-Flex 10x Depends on clamp scaling and V nominal ± 1% ± 10 counts Excluding line resistance accuracy
Harmonics
Harmonic Order (n)   DC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7
Inter-Harmonic Order (n)   OFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7
Volts %f 0.0 % to 100 % 0.1 % ± 0.1% ± n x 0.1 %
%r 0.0 % to 100 % 0.1 % ± 0.1% ± n x 0.4 %
Absolute 0.0 to 1000 V 0.1 V ± 5% *
THD 0.0 % to 100 % 0.1 % ± 2.5 %
Amps %f 0.0 % to 100 % 0.1 % ± 0.1% ± n x 0.1%
%r 0.0 % to 100 % 0.1 % ± 0.1% ± n x 0.4 %
Absolute 0.0 to 600 A 0.1 A ± 5% ± 5 counts
THD 0.0 % to 100 % 0.1 % ± 2.5 %
Watts %f or %r  0.0 % to 100 % 0.1 % ± n x 2%
Absolute Depends on clamp scaling and V nominal  ± 5% ± n x 2 % ± 10 counts
THD 0.0 % to 100 %   0.1 % ± 5 %
Phase Angle   -360° to +0° ± n x 1°
Flicker
Plt, Pst, Pst(1min) Pinst   0.00 to 20.00 0.01 ± 5 %
Unbalance
Volts % 0.0 % to 20.0 % 0.1 % ± 0.1 %
Amps % 0.0 % to 20.0 % 0.1% ± 1 %
Mains Signaling
Threshold Levels   Threshold, limits and signaling duration is programable for two signaling frequencies
Signaling Frequency   60 Hz to 3000 Hz 0.1 Hz  
Relative V%   0 % to 100 % 0.10 % ± 0.4 %
Absolute V3s (3 second avg.)   0.0 V to 1000 V 0.1 V ± 5 % of nominal voltage
General specifications
Case Design Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 /Hz according to MIL-PRF-28800F Class 2
Display Brightness: 200 cd/m 2 typ. using power adapter, 90 cd/m 2 typical using battery power Size: 127 mm x 88 mm (153 mm/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated
Memory 8GB SD card (SDHC compliant, FAT32 formatted) standard, upto 32GB optionally Screen save and multiple data memories for storing data including recordings (dependent on memory size)
Real-Ttime Clock Time and date stamp for Trend mode, Transient display, System Monitor and event capture
Environmental
Operating Temperature 0 °C ~ +40 °C; +40 °C ~ +50 °C excl. battery
Storage Temperature -20 °C ~ +60 °C
Humidity +10 °C ~ +30 °C: 95% RH non-condensing

+30 °C ~ +40 °C: 75% RH non-condensing

+40 °C ~ +50 °C: 45% RH non-condensing

Maximum Operating Altitude Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V

Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V

Maximum storage altitude 12 km (40,000 ft)

Electro-Magnetic-Compatibility (EMC) EN 61326 (2005-12) for emission and immunity
Interfaces mini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery
Warranty Three years (parts and labor) on main instrument, one year on accessories

    * ± 5 % if ≥ 1 % of nominal voltage ± 0.05 % of nominal voltage if < 1% of nominal voltage
   ** 50Hz/60Hz nominal frequency according to IEC 61000-4-30
 *** 400Hz measurements are not supported for Flicker, Mains Signaling and Monitor Mode
**** For nominal voltage 50 V to 500 V


Fluke 437-II/BASIC Product Specifications Summary:
(for full specs please see the full specs tab or the data sheet)

Power Measurement/Power Quality Analyzer Template

Type (Power Quality) What's This?3 Phase, Single Phase
Maximum Current AC What's This?6000 A 
Maximum Current DC600 A 
Maximum Voltage AC1000 V 
Maximum Voltage DC1000 V 
True Power / Work ( W) What's This?Yes
Apparent Power (VA) What's This?Yes
Reactive Power (VAR) What's This?Yes
Current Input Channels4
Voltage Input Channels4
Measurement Frequency (Power Quality)400 Hz, 50 Hz, 60 Hz
Display (Power Quality)Digital, Graphical, Oscilloscope
AlarmsYes
Transient Capture What's This?Yes
Minimum Transient Durationmicro-seconds 
Displays Waveform What's This?Yes
Energy What's This?Yes
Phasor Diagrams What's This?Yes
Power Factor (Power Quality) What's This?Yes
Harmonics What's This?Yes 
Maximum Harmonics Range50
Current Clamps IncludedYes
Class A Compliant What's This?Yes
Crest FactorYes
CAT Rating What's This?IV 
CAT Voltage Rating (V) What's This?1000V, 600V
GPS LocationYes 

Test Equipment General Attributes

Unique FeaturesThe Fluke 437 Series II Power Quality and Energy
Analyzer is designed specifically for the defense
and avionics industries. Equipped with all the
functionalities of the 435 II including PowerWave,
Power Inverter Efficiency and an Energy Loss
Calculator, the 437 II goes one step further by
measuring up to 400 Hz. The ability to measure
at a higher frequency is necessary for those
working in submarines, aircrafts, and other transport applications.
Warranty3 YEARS
Warranty DetailsThree years (parts and labor) on main instrument, one year on accessories
Calibration IncludedNone
Power Supply Voltage120V/220V Universal, Battery Powered
Safety ApprovalCSA, UL 
Data Logging What's This?Yes
Interfaces I/O Analog Output, Other, RS-232, Analog Input , USB 
StorageSD Card 
IP Rating What's This?IP51 
Product Weight4.4 LBS
Battery TypeLi-ion 
Product Height2.76 IN
Product Length10.43 IN
Product Width7.48 IN
Shipping Weight13.2 LBS
Country of OriginRomania
Shipping Height28 IN
Shipping Length41 IN
Shipping Width36 IN
UPC095969615617

Reviews

Accessories

Loading Accessories

Reviews

Fluke 437-II/BASIC Customer Reviews

0 Reviews
5 stars
 (0)
4 stars
 (0)
3 stars
 (0)
2 stars
 (0)
1 star
 (0)
 
 
 
 
 
Average Customer Review
         
0 reviews
0 customer reviews
Share your thoughts with other customers
Create your own review
No reviews found to display for this rating.

Fluke Price List

Hioki Clampon HiTester
X


secured website

Interworld Highway, LLC dba TEquipment.NET

205 Westwood Avenue. Long Branch, NJ 07740

Privacy Policy | Terms and Conditions | Site Map

Copyright© 2016 Interworld Highway, LLC

secured website
We Price Match!

Give our sales team a call at 877.571.7901 (Toll Free) or 732.222.7077 (International) and we'll match any competitor's price.

X