Fluke 1586A 120 Super-DAQ Precision Temperature Scanner, Mainframe Only, 120V

 
Fluke 1586A 120
Catalog #: 4409886
         
5 of 5
SUPER-DAQ, MAINFRAME ONLY, 120 V
Free Gift From Fluke With Purchase

Features

  • 1586A 120 Super-DAQ Precision Temperature Scanner
  • Mainframe Only
  • 120V
  • Best-in-class temperature measurement accuracy
    • PRTs ± 0.005 °C (using external DAQ‑STAQ Multiplexer)
    • Thermocouples: ± 0.5 °C (using High-Capacity Module and internal CJC)
    • Thermistors: ± 0.002 °C
  • Input channels: Up to 40 isolated universal inputs
  • Flexible configuration: Internal High-Capacity Module and/or DAQ-STAQ Multiplexer
  • Selectable scan speed: Up to 10 channels per second
  • Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM)
  • Real-time color trending: Chart up to four channels simultaneously
  • 6 1/2 digit display resolution for dc voltage, dc current, and resistance
  • Current reversal minimizes thermoelectric effects, improving PRT/RTD measurement accuracy
  • Automated sensor calibration: Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines
  • Data storage: Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive. Transfer data to a PC using the USB drive or LAN connection and view data in Microsoft® Excel
  • Data security: Administrator and user profiles for protecting settings and ensuring test traceability
  • Mx + B scaling and channel offset zero function
  • Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded
Loading Prices
List Price: $2,625.00
Loading Callouts
0% APR Financing Available - Eligibility Subject to Applicant's Creditwothiness
Questions?
Ask Our Factory
Trained Engineers
• 877.571.7901
Loading Series Compare

Compare Products in this Series

Product Name Country of Origin Availability Price
1586A/2DS 120/C
1586A/2DS 120/C
SUPER-DAQ, 2 DAQ-STAQ MODULES, 120V, ACCREDITED CAL
China Edu Price Standard Price Gov't Price
1586A/2DS 120
1586A/2DS 120
SUPER-DAQ, 2 DAQ-STAQ MODULES, 120 V
China Edu Price Standard Price Gov't Price
1586A/DSHC 120/C
1586A/DSHC 120/C
SUPER-DAQ, 1 INT/1 EXT MODULE, 120V, ACCREDITED CAL
China Edu Price Standard Price Gov't Price
1586A/DS-HC 120
1586A/DS-HC 120
SUPER-DAQ, 1 INT/1 EXT MODULE, 120 V
China Edu Price Standard Price Gov't Price
1586A/1DS 120/C
1586A/1DS 120/C
SUPER-DAQ, 1 DAQ-STAQ MODULE, 120V, ACCREDITED CAL
China Edu Price Standard Price Gov't Price
1586A/1DS 120
1586A/1DS 120
SUPER-DAQ, 1 DAQ-STAQ MODULE, 120 V
China Edu Price Standard Price Gov't Price
1586A/2HC 120/C
1586A/2HC 120/C
SUPER-DAQ, 2 HI-CAPACITY MODULES, 120V, ACCREDITED CAL
China Edu Price Standard Price Gov't Price
1586A/2HC 120
1586A/2HC 120
SUPER-DAQ, 2 HI-CAPACITY MODULES, 120 V
China Edu Price Standard Price Gov't Price
1586A/1HC 120/C
1586A/1HC 120/C
SUPER-DAQ, 1 HI-CAPACITY MODULE, 120V, ACCREDITED CAL
China Edu Price Standard Price Gov't Price
1586A/1HC 120
1586A/1HC 120
SUPER-DAQ, 1 HI-CAPACITY MODULE, 120 V
China Edu Price Standard Price Gov't Price
Fluke 1586A/1DS 120 Super-DAQ Precision Temperature Scanner

Fluke 1586A 120 Super-DAQ Precision Temperature Scanner, Mainframe Only, 120V

         
5 of 5

Product Information

Fluke 1586A 120 Super-DAQ Precision Temperature Scanner, Mainframe Only, 120V.

The 1586A Super-DAQ collects time-stamped precision temperature and electrical measurements for data analysis by technicians, engineers, and quality control personnel to verify process control, analyze interactive systems, ensure conformance to quality standards, or to correlate related events for R&D or troubleshooting. Measurement data and statistics can be viewed in tabular format for all active channels. With the graphing feature, up to four channels can be plotted at the same time, making it easy to quickly assess test setup and results before analyzing the data on a PC.  

When configured with the DAQ-STAQ Multiplexer, the Super-DAQ has the accuracy of the best benchtop reference thermometer readouts for calibration of PRTs, RTDs, thermistors, or thermocouples. Lab efficiency can be increased when the Super-DAQ is connected to a Fluke Calibration drywell or bath and Automated Sensor Test routines are run.

The 1586 is ideal for a number of applications such as thermal mapping, temperature validation, process sensor calibration, and more. These applications are found in a various industries including pharmaceutical, biotechnology, food processing, aerospace, and automotive.

There are six key features that set the Super-DAQ apart from other products in its class:
  1. Best temperature measurement accuracy
  2. Flexible configuration for the factory or benchtop
  3. Multiple modes of operation
  4. Real-time graphing in color
  5. Data portability and security
  6. Automated sensor calibration
1. Best temperature measurement accuracy
The 1586A Super-DAQ reads PRTs, thermocouples, and thermistors with best-in-class accuracy:
  • PRTs ± 0.005 °C (using external DAQ-STAQ Multiplexer)
  • Thermocouples: ± 0.5 °C (using High-Capacity Module and internal CJC)
  • Thermistors: ± 0.002 °C
2. Flexible configuration for the factory or benchtop
For factory applications, the Super-DAQ is configured with the internal High-Capacity Module. Connecting thermocouples or RTDs to input terminals can be time consuming—especially if you're using many sensors of the same type for one job, and then switching to a different sensor type for another job. The internal High-Capacity Module allows you to pre-configure multiple input modules and simply exchange one module for another, depending on your test requirements. Recall a stored test setup to make the changeover even faster. And if you prefer, you can always measure a variety of different input types at the same time in a single High-Capacity Module, including thermocouples, RTDs, voltage, resistance, or current.  

For a calibration lab where accuracy is of primary importance, the Super-DAQ is best configured with a DAQ-STAQ Multiplexer. The external DAQ-STAQ features mini-jack thermocouple terminals—each with its own reference junction sensor—and patented mini-DWF, gold-plated input terminals, which accept bare wire, spade lug, or mini-banana-plug terminations. Easily connect and disconnect PRTs, thermistors, and thermocouples for benchtop temperature calibration. It can be stacked on the 1586 to reduce footprint in busy labs. Flexibility to configure the Super-DAQ for factory or calibration lab use reduces your equipment needs and cost.
3. Multiple modes of operation
The Super-DAQ can operate in four modes that let you scan, monitor, measure, or function as a digital multimeter from a single instrument. Sequentially scan through channels based on a user defined test. Monitor any single channel during a scan, without interrupting the scan. Measure and record data on a single channel without the need of a pre-configured test file. Or in DMM mode, use the front panel channel like a familiar benchtop digital multimeter to quickly measure dc voltage, dc current, or 2-wire and 4-wire resistance without the need to configure the channel.
4. Real-time graphing in color
Most data acquisition systems only let you view data on one channel. But now the Super-DAQ, lets you view real time data for all channels in table format, or you can chart up to four channels in color at the same time. You can zoom in or out to see data of interest and monitor trends. A history mode lets you scroll through collected data within a scan file—all without a PC and expensive charting programs. Switch between chart view and table view of various measurement data and statistics
5. Data portability and security
The Super-DAQ includes 20 MB internal memory that can store over 75,000 time-stamped readings. Data and set-up files can be easily moved to a PC for analysis using a USB flash drive or over a network using the LAN interface connection. The Super-DAQ also includes two levels of data security to prevent unauthorized users from tampering with or forging test data or setup files. This security feature is especially important to industries that are regulated by government agencies where data traceability is required.
6. Automated sensor calibration
With the Automated Test feature, you can automate sensor calibration without a PC and software. When connected to a Fluke Calibration drywell or fluid bath via the RS-232 interface, the Super-DAQ takes control of the temperature source and runs your calibration automatically. You simply program the number of setpoint temperatures and their values, select a scan sequence (linear, alternate, up/down), assign a reference channel, and set the required stability band. The Super-DAQ monitors the temperature source's stability via the reference channel, collects the data once stabilized, and then advances to the next setpoint temperature. After you configure and start the test, you can walk away to work on other things. The Super-DAQ just made your day a whole lot easier.
1586A Super-DAQ at a glance

 
1586A-Super-DAQ-at-a-glance-Front-Panel_tn
1586A-Super-DAQ-at-a-glance-Back-Panel_tn
1586-2586 High-Capacity Module

Universal input channels designed to measure temperature, resistance, dc voltage, and dc current for data acquisition applications on the factory floor where channel count and scan speed are important.
 

1586-2586-High-Capacity-Module_tn
1586-2588 DAQ-STAQ Multiplexer
Designed for high-accuracy measurements in secondary temperature calibration labs. Easily connect/disconnect thermocouples, PRTs, and thermistors.
 
1586-2588-DAQ-STAQ-Multiplexer_tn

Specifications

General Specifications
Mains Voltage 100 V Setting: 90 V to 110 V
120 V Setting: 108 V to 132 V
220 V Setting: 198 V to 242 V
240 V Setting: 216 V to 264 V
Frequency 47 Hz to 440 Hz
Power Consumption 36 VA peak (24 W average)
Environment
Temperature
Operating: 0 °C to 50 °C
Full accuracy: 18 °C to 28 °C
Storage: −20 °C to 70 °C
Warm-up: 1 hour to full accuracy specifications
Relative Humidity
(non-condensing)
Operating: 0 °C to 30 °C <80 %;
                 30 °C to 50 °C <50 %
Storage: −20 °C to 70 °C <95 %
Altitude Operating: 2,000 m
Storage: 12,000 m
Vibration and Shock Complies with MIL-PRF-28800F Class 3
Channel Capacity  
  Total analog channels: 45
Voltage/resistance channels: 41
Current channels: 5
Digital I/O: 8 bits
Totalizer: 1
Alarm outputs: 6
Trigger input: 1
Input Protection 50 V all functions, terminals and ranges
Math Channels Number of channels: 20
Operations: sum, difference, multiply, divide, polynomial, power, square
root, reciprocal, exponential, logarithm, absolute value, average, maximum,
minimum
Triggers interval, external (trigger input), alarm, remote (bus), manual, automated
test
Memory Scan data RAM: 75,000 readings with timestamp
Data/Setup flash memory: 20 MB
USB Host Port Connector type: Type A
Function: Memory
File system: FAT32
Memory capacity: 32 GB
USB Device Port Connector type: Type B
Class: Instrument
Function: Control and data transfer
Command protocol: SCPI
LAN Function: Control and data transfer
Network protocols: Ethernet 10/100, TCP/IP
Command protocol: SCPI
RS-232 Connector: D-sub 9 pin (DE-9)
Baud rates: 1200, 2400, 4800, 9600, 19200, 38400
Function: Temperature source control output
Dimensions Height: 150 mm
Width: 245 mm
Depth: 385 mm Weight: 6 kg (typical configuration)
Shipping Weight: 9.5 kg (typical configuration)
Conformity CE, CSA, IEC 61010 3rd ed.
Measurement Specifications
Accuracy specifications generally apply with medium and slow sample rates (unless otherwise noted),
after a warm-up time of 1 hour, and within an environment temperature range of 18 °C to 28 °C, and
may depend on the channel. The confidence level for accuracy specifications is 95 % within 1 year of
calibration.
Scan rate Fast: 10 channels per second max (0.1 seconds per channel) Medium: 1 channel
per second (1 second per channel)
Slow: 4 seconds per channel
Display Resolution 6 1/2 digits (see Measurement Characteristics tables below to find the display
resolution of temperature readings)
PRT/RTD
Temperature Range −200 °C to 1200 °C (depending on the sensor)
Resistance Range 0 Ω to 4 kΩ
Offset Compensation 0 Ω to 400 Ω, 4-wire: automatic current
reversal
400 Ω to 4000 Ω or 3-wire: none
Source Current Reversal Interval (0 Ω to 400 Ω
range)
Fast sample rate: 2 ms
Medium sample rate: 250 ms
Slow sample rate: 250 ms
Maximum Lead Resistance (4-wire Ω) 2.5 % of range per lead for 400 Ω and 4 kΩ
ranges
PRT/RTD Resistance Accuracy
Accuracy is given as % of measurement or ohms, whichever is greater. Basic accuracy is for 4-wire PRT/RTD. When using 3-wire
PRT/RTD add 0.013 Ω to the accuracy specification for internal resistance
mismatch and voltage offset if using Channel 1, or add 0.05 Ω if using channels x01 through x20. If the
environment temperature is outside the specified range, multiply the temperature coefficient numbers
by the temperature deviation and add to the accuracy specification.
Range Sample Rate DAQ-STAQ Module and
Channel 1
High-Capacity
Module
T.C./ °C Outside 18
°C to 28 °C
0 Ω to
400 Ω
Slow 0.002 % or 0.0008 Ω 0.003 % or 0.003 Ω 0.0001 % or
0.0008 Ω
Medium 0.002 % or 0.002 Ω 0.003 % or 0.003 Ω 0.0001 % or
0.0008 Ω
Fast 0.002 % or 0.005 Ω 0.003 % or 0.006 Ω 0.0001 % or
0.0008 Ω
400 Ω to
4 kΩ
Slow 0.004 % or 0.06 Ω 0.006 % or 0.06 Ω 0.0001 % or 0.008 Ω
Medium 0.004 % or 0.1 Ω 0.006 % or 0.1 Ω 0.0001 % or 0.008 Ω
Fast 0.004 % or 0.18 Ω 0.006 % or 0.18 Ω 0.0001 % or 0.008 Ω
PRT/RTD Temperature Accuracy
Accuracy is for 4-wire 100 Ω nominal PRT/RTD. When using 3-wire PRT/RTD add 0.039 °C to the accuracy
specification for internal resistance mismatch and voltage offset if using Channel 1, or add 0.15 °C if
using channels x01 through x20. If the environment temperature is outside the specified range, multiply
the temperature coefficient number by the temperature deviation and add to the accuracy specification.
Linear interpolation may be used between points in the table. Specifications do not include sensor
accuracy. The practical range of temperature measurement depends on the sensor and characterization
Sample
Rate
Temperature DAQ-STAQ Module and
Channel 1
High-Capacity
Module
T.C./ °C Outside
18 °C to 28 °C
Slow −200 °C 0.002 °C 0.008 °C 0.002 °C
0 °C 0.005 °C 0.008 °C 0.003 °C
300 °C 0.012 °C 0.018 °C 0.006 °C
600 °C 0.02 °C 0.03 °C 0.01 °C
Medium −200 °C 0.005 °C 0.008 °C 0.002 °C
0 °C 0.005 °C 0.008 °C 0.003 °C
300 °C 0.012 °C 0.018 °C 0.006 °C
600 °C 0.02 °C 0.03 °C 0.01 °C
Fast −200 °C 0.013 °C 0.015 °C 0.002 °C
0 °C 0.013 °C 0.015 °C 0.003 °C
300 °C 0.014 °C 0.018 °C 0.006 °C
600 °C 0.02 °C 0.03 °C 0.01 °C
PRT/RTD Measurement Characteristics
  Temperature Display Resolution  
Range Slow / Medium Sample Rate Fast Sample Rate Source Current
0 Ω to 400 Ω 0.001 °C 0.01 °C ±1 mA
400 Ω to 4 kΩ 0.001 °C 0.01 °C .1 mA
Thermistor
Temperature Range −200 °C to 400 °C (depending on the sensor)
Resistance Range 0 Ω to 1 MΩ
Thermistor Resistance Accuracy
Accuracy is given as ± (% of measurement + Ω). The basic accuracy specification is for 4-wire thermistor,
slow sample rate. When using medium or fast sample rate, add the number given in the table to the
accuracy specification. If the environment temperature is outside the specified range, multiply the
temperature coefficient numbers by the temperature deviation and add to the accuracy specification. For
2-wire thermistor add 0.02 Ω internal resistance if using Channel 1 or
1.5 Ω if using channels x01 through x20, and add external lead wire resistance.
Range Slow Sample Rate Medium
Sample Rate
Rate
Fast
Sample
Rate
T.C./ °C
Outside18 °C
to 28 °C
0 Ω to 2.2 kΩ 0.004 % + 0.2 Ω add 0.3 Ω add 1 Ω 0.0005 % +
0.05 Ω
2.1 kΩ to 98 kΩ 0.004 % + 0.5 Ω add 0.5 Ω add 1.3 Ω 0.0005 % +
0.1 Ω
95 kΩ to 1 MΩ 0.015 % + 5 Ω add 5 Ω add 13 Ω 0.001 % +
2 Ω
Thermistor Temperature Accuracy
Accuracy specifications are for 4-wire thermistor. When using 2-wire thermistor, add the number given in
the table to the specification for internal resistance. If the environment temperature is outside the
specified range, increase the accuracy specification by 25 % for every 1 °C outside the specified
environment temperature range. Specifications do not include sensor accuracy. The practical range of
temperature measurement depends on the sensor.
  Accuracy 2.2 Ω Thermistor
Temperature Slow Sample Rate MediumSample
Rate
FastSample
Rate
2-wire
−40 °C 0.001 °C 0.001 °C 0.01 °C add 0.001 °C
0 °C 0.003 °C 0.004 °C 0.01 °C add 0.004 °C
25 °C 0.006 °C 0.011 °C 0.02 °C add 0.016 °C
50 °C 0.008 °C 0.018 °C 0.04 °C add 0.05 °C
100 °C 0.047 °C 0.114 °C 0.28 °C add 0.34 °C
150 °C 0.23 °C 0.56 °C 1.34 °C add 1.7 °C
  Accuracy 5 Ω Thermistor
Temperature Slow Sample Rate MediumSample
Rate
FastSample
Rate
2-wire
−40 °C 0.003 °C 0.004 °C 0.01 °C add 0.001 °C
0 °C 0.002 °C 0.002 °C 0.01 °C add 0.002 °C
25 °C 0.004 °C 0.006 °C 0.01 °C add 0.007 °C
50 °C 0.005 °C 0.009 °C 0.02 °C add 0.022 °C
100 °C 0.022 °C 0.052 °C 0.13 °C add 0.16 °C
150 °C 0.096 °C 0.24 °C 0.57 °C add 0.7 °C
  Accuracy 10 Ω Thermistor
Temperature Slow Sample Rate MediumSample
Rate
FastSample
Rate
2-wire
−40 °C 0.003 °C 0.004 °C 0.01 °C add 0.001 °C
0 °C 0.002 °C 0.002 °C 0.01 °C add 0.002 °C
25 °C 0.003 °C 0.004 °C 0.01 °C add 0.004 °C
50 °C 0.005 °C 0.009 °C 0.02 °C add 0.011 °C
100 °C 0.011 °C 0.024 °C 0.06 °C add 0.067 °C
150 °C 0.04 °C 0.098 °C 0.24 °C add 0.29 °C
Thermistor Measurement Characteristics
  Temperature Display Resolution  
Range Slow / Medium
Sample Rate
Fast
Sample Rate
Source Current
0 Ω to 2.2 Ω 0.0001 °C 0.001 °C 10 μA
2.1 Ω to 98 Ω 0.0001 °C 0.001 °C 10 μA
95 Ω to 1 MΩ 0.0001 °C 0.001 °C 1 μA
Thermocouple
Temperature Range −270 °C to 2315 °C (depending on the sensor)
Voltage Range −15 mV to 100 mV
Thermocouple Voltage Accuracy
Accuracy is given as ± (|% of measurement| + μV). Basic accuracy specification is for medium or slow
sample rate. When using a fast sample rate add the number given in the table to the accuracy
specification. If the environment temperature is outside the specified range, multiply the temperature
coefficient numbers by the temperature deviation and add to the accuracy specification.
Range Accuracy Channel
1
Ch. x01 –
x20
Fast Sample
Rate
T.C./ °C Outside
18 °C to 28 °C
−15 mV to 100 mV 0.004 % + 4 μV add 2 μV add 1 μV 0.0005 % + 0.0005
mV
Thermocouple Reference Junction Accuracy
Module CJC Accuracy T.C./ °C Outside
18 °C to 28 °C
DAQ-STAQ Module 0.25 °C 0.02 °C
High-Capacity Module 0.6 °C 0.05 °C
Thermocouple Temperature Accuracy
Accuracy specifications apply using medium or slow sample rate. When using fast sample rate, increase
the accuracy specification by 25 %. If the environment temperature is outside the specified range,
increase the accuracy specification by 12 % for every 1 °C outside the specified environment temperature
range. Accuracy with fixed/external CJC does not include the accuracy of the reference junction
temperature. Linear interpolation may be used between points in the table. Specifications do not include
sensor accuracy. The practical range of temperature measurement depends on the sensor.
Type
(Range)
Temperature Accuracy
Fixed / External CJC Internal CJC
Channel 1 Ch. x01 –
x20
DAQ-STAQ
Module
High-Capacity
Module
K
−270 °C to
1372 °C
−200 °C
0 °C
1000 °C
0.28 °C
0.10 °C
0.14 °C
0.41 °C
0.15 °C
0.20 °C
0.76 °C
0.29 °C
0.32 °C
1.60 °C
0.62 °C
0.64 °C
T
−270 °C to
400 °C
−200 °C
0 °C
200 °C
400 °C
0.27 °C
0.10 °C
0.08 °C
0.08 °C
0.40 °C
0.15 °C
0.12 °C
0.11 °C
0.76 °C
0.30 °C
0.23 °C
0.20 °C
1.60 °C
0.65 °C
0.47 °C
0.41 °C
R
−50 °C to
1768 °C
0 °C
300 °C
1200 °C
1600 °C
0.76 °C
0.42 °C
0.33 °C
0.34 °C
1.13 °C
0.63 °C
0.47 °C
0.49 °C
1.16 °C
0.64 °C
0.48 °C
0.50 °C
1.28 °C
0.71 °C
0.52 °C
0.54 °C
S
−50 °C to
1768 °C
0 °C
300 °C
1200 °C
1600 °C
0.74 °C
0.45 °C
0.37 °C
0.39 °C
1.11 °C
0.67 °C
0.54 °C
0.56 °C
1.14 °C
0.68 °C
0.55 °C
0.57 °C
1.26 °C
0.76 °C
0.60 °C
0.63 °C
J
−210 °C to
1200 °C
−200 °C
0 °C
1000 °C
0.20 °C
0.08 °C
0.11 °C
0.29 °C
0.12 °C
0.14 °C
0.65 °C
0.28 °C
0.25 °C
1.41 °C
0.61 °C
0.53 °C
N
−270 °C to
1300 °C
−200 °C
0 °C
500 °C
1000 °C
0.42 °C
0.15 °C
0.12 °C
0.14 °C
0.62 °C
0.23 °C
0.17 °C
0.19 °C
0.90 °C
0.34 °C
0.24 °C
0.26 °C
1.69 °C
0.64 °C
0.44 °C
0.45 °C
E
−270 °C to
1000 °C
−200 °C
0 °C
300 °C
700 °C
0.17 °C
0.07 °C
0.06 °C
0.08 °C
0.25 °C
0.10 °C
0.09 °C
0.10 °C
0.64 °C
0.27 °C
0.21 °C
0.21 °C
1.42 °C
0.61 °C
0.46 °C
0.45 °C
B
100 °C to
1820 °C
300 °C
600 °C
1200 °C
1600 °C
1.32 °C
0.68 °C
0.41 °C
0.38 °C
1.97 °C
1.02 °C
0.60 °C
0.55 °C
1.97 °C
1.02 °C
0.60 °C
0.55 °C
1.97 °C
1.02 °C
0.60 °C
0.55 °C
C
0 °C to
2315 °C
600 °C
1200 °C
2000 °C
0.23 °C
0.28 °C
0.44 °C
0.33 °C
0.40 °C
0.60 °C
0.37 °C
0.45 °C
0.66 °C
0.54 °C
0.63 °C
0.91 °C
D
0 °C to
2315 °C
600 °C
1200 °C
2000 °C
0.22 °C
0.26 °C
0.39 °C
0.32 °C
0.36 °C
0.53 °C
0.34 °C
0.39 °C
0.56 °C
0.44 °C
0.49 °C
0.69 °C
G
0 °C to
2315 °C
600 °C
1200 °C
2000 °C
0.24 °C
0.22 °C
0.33 °C
0.36 °C
0.32 °C
0.46 °C
0.36 °C
0.32 °C
0.46 °C
0.36 °C
0.33 °C
0.46 °C
L
−200 °C to
900 °C
−200 °C
0 °C
800 °C
0.13 °C
0.08 °C
0.09 °C
0.19 °C
0.12 °C
0.12 °C
0.45 °C
0.28 °C
0.23 °C
0.99 °C
0.62 °C
0.48 °C
M
−50 °C to
1410 °C
0 °C
500 °C
1000 °C
0.11 °C
0.10 °C
0.10 °C
0.16 °C
0.15 °C
0.14 °C
0.30 °C
0.25 °C
0.21 °C
0.64 °C
0.51 °C
0.41 °C
U
−200 °C to
600 °C
−200 °C
0 °C
400 °C
0.25 °C
0.10 °C
0.08 °C
0.37 °C
0.15 °C
0.11 °C
0.71 °C
0.30 °C
0.20 °C
1.48 °C
0.63 °C
0.40 °C
W
0 °C to
2315 °C
600 °C
1200 °C
2000 °C
0.24 °C
0.22 °C
0.33 °C
0.36 °C
0.32 °C
0.46 °C
0.36 °C
0.32 °C
0.46 °C
0.36 °C
0.33 °C
0.46 °C
Thermocouple Measurement Characteristics
Range Temperature Display Resolution
Slow / Medium
Sample Rate
Fast
Sample Rate
−270 °C to 2315 °C 0.01 °C 0.1 °C
DC Voltage
Maximum Input 50 V on any range
Common Mode Rejection 140 dB at 50 Hz or 60 Hz (1 kΩ unbalance in LOW lead) ±50 V peak
maximum
Normal Mode Rejection 55 dB for power line frequency ±0.1 %, ±120 % of range peak maximum
A/D Linearity 2 ppm of measurement + 1 ppm of range
Input Bias Current 30 pA at 25 °C
DC Voltage Accuracy
Accuracy is given as ± (% measurement + % of range). Basic accuracy specification is for Channel 1,
medium or slow sample rate. For channels x01 through x20 or when using Fast sample rate, add the
numbers given in the table to the accuracy specification. If the environment temperature is outside the
specified range, multiply the temperature coefficient numbers by the temperature deviation and add to
the accuracy specification.
Range Accuracy Channel 1 Ch.
x01 –
x20
Fast
Sample
Rate
T.C./ °C
Outside
18 °C to
28 °C
±100 mV 0.0037 % + 0.0035 % add
2 μ
add
0.0008 %
of range
0.0005 %
+
0.0005 %
±1 V 0.0025 % + 0.0007 % add
2 μ
add
0.0008 %
of range
0.0005 %
+
0.0001 %
±10 V 0.0024 % + 0.0005 % add
0.0008 %
of range
0.0005 %
+
0.0001 %
±50 V 0.0038 % + 0.0012 % add
0.0008 %
of range
0.0005 %
+
0.0001 %
DC Voltage Input Characteristics
  Resolution Input Impedance
Range Slow / Medium Fast
±100 mV 0.1 μ 1 μ 10 GΩ [1]
±1 V 1 μ 10 μ 10 GΩ [1]
±10 V 10 μ 100 μ 10 GΩ [1]
±50 V 100 μ 1 mV 10 MΩ ±1 %
[1] - Input beyond ±12 V is clamped. The clamp current is up to 3 mA.
DC Current
Input Protection 0.15 A resettable PTC
DC Current Accuracy
Accuracy is given as ± (% measurement + % of range). Basic accuracy specification is for medium or slow
sample rate. When using a fast sample rate, add the number given in the table to the accuracy
specification. If the environment temperature is outside the specified range, multiply the temperature
coefficient numbers by the temperature deviation and add to the accuracy specification.
Range Accuracy Fast Sample Rate T.C./ °C Outside
18 °C to 28 °C
±100 μA 0.015 % + 0.0035 % add 0.0008 % of range 0.002 % + 0.001 %
±1 mA 0.015 % + 0.0011 % add 0.0008 % of range 0.002 % + 0.001 %
±10 mA 0.015 % + 0.0035 % add 0.0008 % of range 0.002 % + 0.001 %
±100 mA 0.015 % + 0.0035 % add 0.0008 % of range 0.002 % + 0.001 %
DC Current Input Characteristics
Range Slow / Medium Fast Burden Voltage
±100 μA 0.1 nA 1 nA <1 mV
±1 mA 1 nA 10 nA <1 mV
±10 mA 10 nA 100 nA <1 mV
±100 mA 100 nA 1 μA <1 mV
Resistance
Max. Lead Resistance
(4-wire ohms)
10 Ω per lead for 100 Ω and 1 kΩ ranges. 1 kΩ per lead on all other ranges.
Resistance Accuracy
Accuracy is given as ± (% measurement + % of range). Basic accuracy specification is for 4-wire
resistance, medium or slow sample rate. For 2-wire resistance add 0.02 Ω internal resistance if using
Channel 1, or 1.5 Ω if using channels x01 through x20, and add external lead wire resistance. When
using Fast sample rate, add the numbers given in the table to the accuracy specification. If the
environment temperature is outside the specified range, multiply the Temperature Coefficient numbers
by the temperature deviation and add to the accuracy specification
Range Accuracy Fast Sample Rate 1T.C./ °C Outside
8 °C to 28 °C
100 Ω 0.004 % + 0.0035 % add 0.001 % of range 0.0001 % + 0.0005 %
1 kΩ 0.003 % + 0.001 % add 0.001 % of range 0.0001 % + 0.0001 %
10 kΩ 0.004 % + 0.001 % add 0.001 % of range 0.0001 % + 0.0001 %
100 kΩ 0.004 % + 0.001 % add 0.001 % of range 0.0001 % + 0.0001 %
1 MΩ 0.006 % + 0.001 % add 0.002 % of reading
plus 0.0008 % of range
0.0005 % + 0.0002 %
10 MΩ 0.015 % + 0.001 % add 0.002 % of reading
plus 0.0008 % of range
0.001 % + 0.0004 %
100 MΩ 0.8 % + 0.01 % add 0.01 % of range 0.05 % + 0.002 %
Resistance Input Characteristics
Range Resolution
Slow / Medium
Fast Source Current
(open-circuit voltage)
100 Ω 0.1 mΩ 1 mΩ 1 mA (4 V)
1 kΩ 1 mΩ 10 mΩ 1 mA (4 V)
10 kΩ 10 mΩ 100 mΩ 100 μA (6 V)
100 kΩ 100 mΩ 1 Ω 100 μA (12 V)
1 MΩ 1 Ω 10 Ω 10 μA (12 V)
10 MΩ 10 Ω 100 Ω 1 μA (12 V)
100 MΩ 100 Ω 1 kΩ 0.1 μA (12 V)
Digital I/O
Absolute Voltage Range –4 V to 30 V
Input Minimum Logic High 2.0 V
Input Maximum Logic Low 0.7 V
Output Type open drain active low
Output Logic Low (<1 mA) 0 V to 0.7 V
Maximum Sink Current 50 mA
Output Resistance 47 Ω
Totalizer
Absolute Voltage Range –4 V to 30 V
Minimum Logic High 2.0 V
Maximum Logic Low 0.7 V
Minimum Pulse Width 50 μs
Maximum Frequency 10 kHz
Debounce Time 1.7 ms
Maximum Count 1048575 (20 bits)
Trigger
Absolute Voltage Range –4 V to 30 V
Minimum Logic High 2.0 V
Maximum Logic Low 0.7 V
Minimum Pulse Width 50 μs
Maximum Latency 100 ms
Alarm Output
Absolute Voltage Range –4 V to 30 V
Output Type open drain active low
Output Logic Low (<1 mA) 0 V to 0.7 V
Maximum Sink Current 50 mA
Output Resistance 47 Ω
1586-2588 DAQ-STAQ Input Module Specifications
Maximum Input 50 V
Offset Voltage <2 μV
3-Wire Internal Resistance Mismatch <50 mΩ
Basic CJC Accuracy 0.25 °C
1586-2586 High-Capacity Input Module Specifications
Maximum Input 50 V
Offset Voltage <2 μV
3-Wire Internal Resistance Mismatch <50 mΩ
Basic CJC Accuracy 0.6 °C

Reviews

Accessories

Loading Accessories

Reviews

1586A 120 Customer Reviews

1 Reviews
5 stars
 (1)
4 stars
 (0)
3 stars
 (0)
2 stars
 (0)
1 star
 (0)
 
 
 
 
 
Average Customer Review
         
5 of 5
1 customer reviews
Share your thoughts with other customers
Create your own review
Product: Fluke 1586A 120
          5.0
 
Anonymous
Location: Seattle WA USA
Recommended: Yes

Awesome

Good prices - Fast quote response and free shipping
0 out of 0 found this review helpful. Did this help? Yes No
 
No reviews found to display for this rating.

Fluke Price List

Fluke 64 Max - IR Thermometer
X


secured website

Interworld Highway, LLC dba TEquipment.NET

205 Westwood Avenue. Long Branch, NJ 07740

Privacy Policy | Terms and Conditions | Site Map

Copyright© 2016 Interworld Highway, LLC

secured website
We Price Match!

Give our sales team a call at 877.571.7901 (Toll Free) or 732.222.7077 (International) and we'll match any competitor's price.

X