Tequipment
An InterWorld Highway, LLC Company
Call Us 1.877.571.7901
Datalogger Buying Guide
 
 
 
 
 
Top Categories >

AEMC L322 2126.06 Simple Logger II 4 to 20mA Logger

 
AEMC L322
Catalog #: 2126.06
         
0 reviews
Simple Logger II Model L322 (2-Channel, 4 to 20mADC, Current, DataView Software)

Features

  • 2 independent input channels
  • Current measured up to 25mADC with 0.1mA resolution
  • Programmable storage rates from 8 every second to 1 every day
  • 3 user selectable storage modes; Stop when full, FIFO; XRM
  • Stores up to 240,000 measurements in non-volatile memory
  • Powered by two standard AA Alkaline batteries
  • Lightweight, compact, fits anywhere
  • 5 LED indicators quickly and clearly display Logger status
  • Includes DataView software FREE for data storage, real-time display, analysis and report generation
  • 50V Cat III

Applications:

  • Process control monitoring and troubleshooting
  • Sensor monitoring
  • General DC current monitoring
  • Profile temperature, pressure, flow and other parameters directly
Loading Prices
List Price: $379.00
Sale: $360.05
  + Free shipping over $74

Questions?
Ask Our Factory
Trained Engineers
M-F 8AM - 9PM EST
• 877.571.7901

Compare Products in this Series

Product Name Battery Life Max Current Min Current Availability Price
L322
L322
Simple Logger II Model L322 (2-Channel, 4 to 20mADC, Current, DataView...
45 DAYS (1080 HR) N/A N/A
CL601
CL601
Simple Logger II Model CL601 (1-Channel, TRMS, Clamp-on, 0 to 600AAC,...
45 DAYS (1080 HR) N/A N/A
L562
L562
Simple Logger II Model L562 (2-Channel, TRMS, Voltage And Current,...
45 DAYS (1080 HR) N/A N/A
L102
L102
Simple Logger II Model L102 (2-Channel, TRMS, 0 to 1VAC, DataView Software)
45 DAYS (1080 HR) N/A N/A
ML912
ML912
Simple Logger II Model ML912 (2-Channel, TRMS, MiniFlex, 100/1000AAC,...
45 DAYS (1080 HR) 1000 A 0.5 A
L481
L481
Simple Logger II Model L481 (1-Channel, DC, 850V, DataView Software)
45 DAYS (1080 HR)
L101
L101
Simple Logger II Model L101 (1-Channel, TRMS, 0 to 1VAC, DataView Software)
45 DAYS (1080 HR) N/A N/A
L261
L261
Simple Logger II Model L261 (1-Channel, TRMS, 600VAC/DC, DataView...
45 DAYS (1080 HR) N/A N/A
AL834
AL834
Simple Logger II Model AL834 (4-Channel, TRMS, Bluetooth, AmpFlex...
200 HR 3000 A 5 A
ML914
ML914
Simple Logger II Model ML914 (4-Channel, TRMS, Bluetooth, MiniFlex,...
200 HR 1000 A 1 A
L264
L264
Simple Logger II Model L264 (4-Channel, TRMS, Bluetooth, 600VAC/DC,...
L104
L104
Simple Logger II Model L104 (4-Channel, TRMS, Bluetooth, 0 to 1VAC,...
Clearance
65% OFF!
1 remain
L452
L452
Data Logger Model L452 (2-Channel, w/LCD, 100mV/1V/10VDC, 4 to 20mADC,...
AEMC-2126.06

AEMC 2126.06 L322 Simple Logger II 4 to 20mA Logger

         
0 reviews
  Add to cart

Product Information

Simple Logger II Model L322 (2-Channel, 4 to 20mADC, Current, DataView Software) Model L322

The Simple Logger II Model L322 is a two channel 4-20mADC current data logger. The choice of data storage modes and storage rates allows the operator to effortlessly configure the logger to optimize memory usage to the application at hand. Extended Recording Mode (XRM) and delayed start time are just two of the many application friendly features.

The Simple Logger II Model L322 records DC current at user selectable rates from 125 mS to 1 day. Current can be measured up to 25mADC with 0.1mA resolution.

The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView software.

Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and time information. An optically isolated Universal Serial Bus (USB) port provides for the transfer of data from the instrument’s internal memory to the computer for analysis.


DataView Graphing & Analysis Software

The DataView software provides a convenient way to configure and control logging from your computer. Through the use of clear and easy-to-use tabbed dialog boxes, all Simple Logger II functions can be configured and tests can be initiated. Results can be displayed in real time and stored in your PC or the logger. Standard or custom reports may be printed along with the operator’s comments and analysis.

Software Features

  • Display and analyze real-time data on your PC
  • Configure all Data Logger functions and parameters from your PC including sample rate, recording length, channel configuration and more
  • Select storage mode for optimum recording
  • Zoom in and out and pan through sections of the graph to analyze the data
  • Download, display and analyze recorded data
  • Display waveforms, trend graphs, harmonics (AC models) and text summaries, all in real-time
  • Create custom views and reports
  • Print reports using standard or custom templates you design
  • Free software upgrades

Quick and simple configuration of all functions and settings from one dialog box.

Real-time view of trend, waveform and status screens.

Configure all alarm functions with straightforward selections.

3 Recording Modes

Start/Stop Mode
In this mode the operator selects a storage rate from predefined values from 8 per second to 1 every day, then selects a start and stop time. Data is recorded at this rate until the memory is filled or the end recording time and date is reached. The logger then stops recording and goes into standby mode retaining the recorded date.

First In First Out Mode (FIFO)
The operator makes the data storage and recording length selections as described above. If the memory fills before the end date and time occurs, the logger will discard the oldest stored data point and add a new one. This process will continue until the end recording date and time is reached.

Extended Time Recording Mode (XRM)
This unique recording mechanism provides for continuous recording over a longer period of time without the need for the operator's selection or adjustments. The operator selects a starting storage range from predefined values from 8 per second to 1 every day and a recording length. The logger will store data at the rate selected until the memory is filled. The logger will then discard every other stored sample beyond the first one, freeing up half the memory for continuous recording. New samples will be stored at half the previous storage rate, matching the interval with the remaining stored data. This process will repeat each time the memory fills until the operator stops the recording manually, the end recording date and time is reached or the battery runs down.

What's In The Box

  • Typa A to 5-pin mini-B USB 2M
  • DataView Software CD
  • Two 1.5V AA-cell Alkaline batteries
  • User manual

Specifications

Simple Logger II Model L322
Electrical
Channels Two
Input Connection Detachable terminal strip
Measurement Range 0 to 25mAdc
Resolution 0.1mA
Accuracy
(DC and 50/60Hz)
0 to 1mA: unspecified
1mA to 30mA: ±(0.25% of Reading + 100µA)
Sample Rate 8 samples taken at storage interval
Storage Rate Programmable from 125ms to 1 day
Storage Modes Start/Stop, FIFO and Extended Recording Mode (XRM)
Recording Length 15 minutes to 8 weeks, programmable using DataView
Memory 240,000 measurements (512KB)
The recorded data is stored in non-volatile memory and will be retained even if the battery is low or removed.
Communication USB 2.0 optically isolated
Power Source 2 x 1.5V AA-cell alkaline batteries
Battery Life 100 hours to >45 days
(dependent on sample rate and recording length)
Mechanical
Dimensions 5.43 x 2.75 x 1.28" (138 x 70 x 32mm)
Weight (with battery) 6.4 oz (181 grams)
Case UL94-V0
Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz)
Shock IEC 68-2-27 (30G)
Drop IEC 68-2-32 (1m)

AEMC L322 Product Specifications Summary:
(for full specs please see the full specs tab or the data sheet)

Dataloggers / Data Acquisition/Current Dataloggers Template

Battery Life45 DAYS (1080 HR)
Power SourceBattery
# Inputs/Channels2
SAMPLE RATE/Intervals8 samples at storage interval
TRMSNo
Accuracy0.25% of Reading +0.05mA
LCD ScreenNo
Software IncludedYes
Data Output Formatproprietary for use with AEMC DataView
TypeDC
Input TypeCurrent Output

Test Equipment General Attributes

Unique Features4 programmable storage modes.Storage rate 8/sec to 1/day
4 to 20mA DC
Warranty12 MONTHS (1 YEARS)
Additional Info/Comments15 min to 8 weeks programmable
Calibration IncludedFactory Calibration
Power Supply VoltageBattery Powered
Safety ApprovalCE
Data Logging What's This?Yes
Interfaces I/OUSB
StorageCompact Flash
IP Rating What's This?IP40
Product Weight6.4 OUNCES (0.4 LBS)
Battery TypeAA
Product Height1.28 IN
Product Length5.45 IN
Product Width2.75 IN
Shipping Weight4 LBS
ECCN NumberEAR99
Country of OriginUnited States
Shipping Height10.7 IN
Shipping Length6.75 IN
Shipping Width2.75 IN

Reviews

Accessories

Loading Accessories

Reviews

AEMC L322 Customer Reviews

0 Reviews
5 stars
 (0)
4 stars
 (0)
3 stars
 (0)
2 stars
 (0)
1 star
 (0)
 
 
 
 
 
Average Customer Review
         
0 reviews
0 customer reviews
Share your thoughts with other customers
Create your own review
No reviews found to display for this rating.

AEMC Price List

X


secured website

Interworld Highway, LLC dba TEquipment.NET

205 Westwood Avenue. Long Branch, NJ 07740

Privacy Policy | Terms and Conditions | Site Map

Copyright© 2016 Interworld Highway, LLC

secured website
We Price Match!

Give our sales team a call at 877.571.7901 (Toll Free) or 732.222.7077 (International) and we'll match any competitor's price.

X