Dielectric Oil Testing

 
Baur/HVT DPA 75 C - 75 kV Oil Breakdown Tester
Catalog: 415+046
  • Product Height: 29.00 IN
  • Product Length: 27.00 IN
  • Product Width: 21.00 IN
  • Shipping Height: 29.00 IN
  • Shipping Length: 27.00 IN
  • Shipping Width: 21.00 IN
In Stock:
  • View Payment Options
Chat with us for price
Baur/HVT DTA 100 C - 100 kV Oil Breakdown Tester
Catalog: 415+043
  • Product Height: 32.00 IN
  • Product Length: 27.00 IN
  • Product Width: 21.00 IN
  • Shipping Weight: 115 LBS
Chat with us for price
Baur/HVT DTL C - Fully Automatic Oil Power Factor/Dissipation Factor Tester
Catalog: 415+044
  • Product Height: 32.00 IN
  • Product Length: 27.00 IN
  • Product Width: 21.00 IN
  • Shipping Weight: 107 LBS
Chat with us for price
Phenix LD100 100 kVAC Oil Dielectric Test Set
  • Warranty: 1 YEARS
  • Product Height: 30.00 IN
  • Product Length: 32.00 IN
  • Product Width: 40.00 IN
  • HTS/Schedule B Number: 9030.33.0080
  • Country of Origin: United States

Your Price: $9,990.00

Sign-in for EDU Pricing!

In Stock:
Phenix LD100-230 Liquid Dielectric Test Sets
  • Warranty: 1 YEARS
  • Product Height: 30.00 IN
  • Product Length: 32.00 IN
  • Product Width: 40.00 IN
  • HTS/Schedule B Number: 9030.33.0080
  • Country of Origin: United States

Your Price: $9,990.00

Sign-in for EDU Pricing!

In Stock:
Phenix Technologies LD60 60 kVAC Oil Dielectric Test Set
  • Dielectric Testing: Yes
  • Maximum Voltage: 30000 V
  • Warranty: 1 YEARS
  • Product Weight: 51 LBS
  • Product Height: 13.75 IN
  • Product Length: 21.25 IN

Your Price: $5,000.00

Sign-in for EDU Pricing!

In Stock:
Phenix LD60-230 Liquid Dielectric Test Sets
  • Dielectric Testing: Yes
  • Maximum Voltage: 30000 V
  • Warranty: 1 YEARS
  • Product Weight: 51 LBS
  • Product Height: 13.75 IN
  • Product Length: 21.25 IN

Your Price: $5,000.00

Sign-in for EDU Pricing!

In Stock:
Phenix LD75 75 kVAC Oil Dielectric Test Set
  • Product Height: 30.00 IN
  • Product Length: 32.00 IN
  • Product Width: 40.00 IN
  • HTS/Schedule B Number: 9030.33.0080
  • Country of Origin: United States
  • Shipping Height: 30.00 IN

Your Price: $8,970.00

Sign-in for EDU Pricing!

In Stock:
Phenix LD75-230 Liquid Dielectric Test Sets
  • Product Height: 30.00 IN
  • Product Length: 32.00 IN
  • Product Width: 40.00 IN
  • HTS/Schedule B Number: 9030.33.0080
  • Country of Origin: United States
  • Shipping Height: 30.00 IN

Your Price: $8,970.00

Sign-in for EDU Pricing!

In Stock:
Hipotronics OC60-DI 60kV Automatic Liquid Oil Dielectric Tester
  • HTS/Schedule B Number: 9026902000
  • ECCN Number: EAR99
  • Country of Origin: United States

List Price: $10,382.23

Your Price: $10,382.22

In Stock:
Hipotronics OC60P-DI - 60kV Digital Liquid Dielectric Tester with Printer
  • Product Height: 19.00 IN
  • Product Length: 21.00 IN
  • Product Width: 24.00 IN
  • Shipping Height: 19.00 IN
  • Shipping Length: 21.00 IN
  • Shipping Width: 24.00 IN

Your Price: $13,155.56

In Stock:
null
null
null
null
null
null
null
null
null
null
null

Recommended for you

Dielectric Oil Testing

Physical properties of insulating oils are important to monitor. Various laboratory test instruments are available to meet the different test methods.

Oil dielectric strength test set is one such test. Excerpt from ASTM D1816 Test Method:
The dielectric breakdown voltage of an insulating liquid is of importance as a measure of the liquid's ability to withstand electric stress without failure. The dielectric breakdown voltage serves to indicate the presence of contaminating agents such as water, dirt, cellulosic fibers, or conducting particles in the liquid, one or more of which may be present in significant concentrations when low breakdown voltages are obtained. However, a high dielectric breakdown voltage does not necessarily indicate the absence of all contaminants; it may merely indicate that the concentrations of contaminants that are present in the liquid between the electrodes are not large enough to deleteriously affect the average breakdown voltage of the liquid when tested by this test method.
 
The oil dielectric strength test instrument carried by TEquipment is suitable for field use and can be powered from a range of mains supplies. The maximum 60 kV output allows tests to be performed on oil from a wide variety of electrical installations including transformers, circuit breakers and other equipment. The operation of the test set is extremely simple and the results are displayed on a bright LED display. A selection of vessels allows the instrument to be configured for a variety of test standards.

The microprocessor controlled, semi-automatic operation allows the user to select a choice of voltage rise rates as specified in many national standards. The start button will then initiate the test. If oil breakdown occurs the instrument will remove the test voltage and display the breakdown value. Alternatively the user can pause the test voltage at any time to carry out a withstand test. The voltage will be maintained at this level for one minute or until breakdown. After one minute the voltage will automatically continue to rise until breakdown occurs or to the maximum output of the instrument.

Over the years various U.S. and International Standards have been developed for oil dielectric strength.  While the instrument may perform multiple tests, test procedure and accessory glassware varies by test. With any order specify the test method(s), so proper glassware can be recommended.

List of Domestic and International Oil Dielectric Strength Test Methods
Test Method Title
ASTM D877 Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes
ASTM D1816 Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using VDE Electrodes
IEC 156 Test Method for Dielectric Breakdown Voltage of Insulating Oils
VDE 370 (German) Test Method for Dielectric Breakdown Voltage of Insulating Oils

Excerpt from ASTM D877
This test method describes two procedures, A and B, for determining the electrical breakdown voltage of insulating liquid specimens. The breakdown test uses ac voltage in the power-frequency range from 45 to 65 Hz. This test method is used to judge if the disk electrode breakdown voltage requirements are met for insulating liquids, as delivered from the manufacturer, that have never been filtered or dried.

Excerpt from ASTM D1816
This test method covers the determination of the dielectric breakdown voltage of insulating liquids (oils of petroleum origin, silicone fluids, high fire-point mineral electrical insulating oils, synthetic ester fluids and natural ester fluids). This test method is applicable to insulating liquids commonly used in cables, transformers, oil circuit breakers, and similar apparatus as an insulating and cooling medium.
X