Impulse / Surge Testers

 
Compliance West 1.2x50-16PF PV - Mega Pulse 1.2x50-16PF PV, Rated to 16kV, Single Tap 10-180nF
Catalog: 00-MP1.2x50-16PF PV
  • Test Method (Safety): IEC 61730-2
  • Product Weight: 140 LBS
  • Product Height: 30 IN
  • Product Length: 23 IN
  • Product Width: 24 IN
  • Shipping Weight: 160 LBS
In Stock:
  • View Payment Options
Call Us
Compliance 124uFx1.6KV PF - MegaPulse 124uFx1.6KV PF
Catalog: 00-MP124uFx1.6KV PF
  • Product Weight: 68 LBS
  • Product Height: 11 IN
  • Product Length: 17 IN
  • Product Width: 17 IN
  • Shipping Weight: 100 LBS
Call Us
Call Us
Compliance Biphasic P EN45502-2 - MegaPulse Surge Tester
Catalog: 00-MPBiphasic P EN45502-2-2
  • Product Weight: 12 LBS
  • Product Height: 5 IN
  • Product Length: 12 IN
  • Product Width: 10 IN
  • Shipping Weight: 13.8 LBS
Call Us
Compliance Biphasic PF 180J - Mega Pulse Biphasic PF 180J
Catalog: 00-MP2P180J
  • Product Weight: 30 LBS
  • Product Height: 9 IN
  • Product Length: 17 IN
  • Product Width: 17 IN
  • Shipping Weight: 50 LBS
Call Us
Compliance C4X18000PF-SJM-C - MegaPulse Impulse Tester, 220V 90A
Catalog: 00-MPC4X18000PF-SJM-C
  • Shipping Weight: 40 LBS
Call Us
Compliance CAP A PF - MegaPulse 1.2x50-12P (12 Ohm, 400-12kV, 3sec Charge Time, 12 Ohm Virtual Impedance)
Catalog: 00-MPCAP A PF
  • Product Weight: 68 LBS
  • Product Height: 17 IN
  • Product Length: 17 IN
  • Product Width: 17 IN
  • Shipping Weight: 78.2 LBS
Call Us
Compliance Defib Surge P 380 - EN45502-2-2 Sec. 20, External Defib Protection Test 1
Catalog: 00-MPDefib Surge P 380
  • Test Method (Safety): N/A
  • Unique Features: Up to 380V test voltage Microcontroller technologies, front panel voltage meter indicates test peak open circuit voltage and polarity Output voltage and polarity are controlled manually from the front panel
  • Warranty: 1 YEARS
  • Warranty Details: N/A
  • Comments: N/A
  • Safety Approval: N/A
Call Us
Compliance MegaPulse 1786P- Surge Tester 1786 P
Catalog: 00-MP1786P
  • Shipping Weight: 15 LBS
Call Us
Compliance MegaPulse Code 360 - Surge Tester, 360J Output Energy
Catalog: 00-MPCode360
  • Unique Features: 360J Output Energy
  • Warranty: 1 YEARS
  • Interfaces I/O: USB
  • Product Weight: 40 LBS
  • Product Height: 18 IN
  • Product Length: 17 IN
Call Us
Compliance MegaPulse D5-PF-001 - Defib-proof and Energy Reduction Tester
Catalog: 00-MPD5-PF-001
  • Test Method (Safety): IEC 60601-1
  • Warranty: 1 YEARS
  • Interfaces I/O: USB
  • Product Weight: 40 LBS
  • Product Height: 18 IN
  • Product Length: 17 IN
Call Us
Compliance MegaPulse Defib-5PF1 - Defib-proof and Energy Reduction Tester
Catalog: 00-MPDefib-5PF-001
  • Shipping Weight: 45 LBS
Call Us
null
null
null
null
null
null
null
null
null
null
null
null

Recommended for you

Impulse / Surge Testers

Impulse Generators originated from the need to test electrical equipment and surge arrestors by simulating the high voltage and current of lightning and other surges. Modern day impulse generators originate from the work of Edwin Marx in the 1920’s. You may see “Marx Generator” or “Marx Circuit” in manufacturer literature. There are two types
  • Impulse Voltage Generators . High voltage pulse is generated by charging multiple capacitors in parallel then discharging in series.
  • Impulse Current Generators. High current pulse is generated by charging multiple capacitors in parallel then discharged in parallel.
The generated voltage and current pulses are extremely fast, in the uSec neighborhood. Over time, different standards have been developed for various equipment, so there is no single model that will test all applications. Therefore, it is important to know first the test method you need to comply with before beginning model selection.

Electrical Safety Test Methods for Equipment


Powered equipment from hand tools, appliances, industrial equipment, and instruments to medical devices and more are tested for electrical safety to various global standards.

For example, IEC 60990 Standard discusses the safety involving the flow of leakage or touch current through the human body. The effect of electric current on a human body can be extremely dangerous. It provides measuring methods for the four body responses:

• Perception
• Reaction
• Let-Go
• Electric Burn

JIS T 0601-1 is the Japanese modification of the existing IEC 60601-1 Safety Standard. IEC 60601-1 is the accepted standard for safety testing of all medical equipment. Both consider safety to be the primary concern.

Here are more standards to consider. Note: It is a partial list. Also, if a test instrument we offer does not specifically list a particular test method, that does not necessarily mean it cannot be used. Since there are so many test methods, the litereture may not enumerate them all. Please contact us with the specific method and we can research it for you.

Partial List of Global Electrical Safety Standards
ANSI / AAMI EC11 Diagnostic Electrocardiographic Devices U.S.
ANSI / AAMI EC13 Cardiac Monitors, Heart Rate Meters, and Alarms U.S.
ANSI / AAMI EC53 ECG Cables and Leadwires U.S.
ANSI / IEEE C37.60 High-voltage Switchgear and Controlgear U.S.
ANSI A92.2 Vehicle Mounted Elevating and Rotating Work Platforms U.S.
BS EN 61557 Electrical safety in low voltage distribution systems up to 1000VAC and 1500VDC British
BS 7671 Requirements for Electrical Installations, IEE Wiring Regulations British
DIN VDE 0701-0702 0701 Repair, Modification, and Inspection of Electrical Equipment. 0702 Periodic Testing of Electrical Equipment German
EN 55024 Information Technology Equipment Europe
GR-1089 Electromagnetic Compatibility and Electrical Safety - Generic Criteria for Network Telecommunication Equipment U.S.
IEC 384-14, Annex A, Table VXI Capacitors Europe
IEC 50144
BS EN 50144
Safety of Hand-held Electric Motor Operated Tools Europe/ British
IEC 60065 Audio, Video, and Similar Electronic Apparatus - Safety Requirements Europe
IEC 60204-1 Safety of Machinery Europe
IEC 60335-1 Safety of Electrical Household Appliances Europe
IEC 60601-1 Medical Electrical Equipment - Part 1: General Requirements for Basic Safety and Essential Performance Europe
IEC 60601-2 Medical Electrical Equipment - Part 2: Particular Requirements for the Basic Safety and Essential Performance of Gamma Beam Therapy Equipment Europe
IEC 60745 Safety of Hand-operated Motor-driven Electric Tools Europe
IEC 60950-1 Safety of Information Technology Equipment Europe
IEC 60990 Methods of Measurement of Touch Current and Protective Conductor Current Europe
IEC 61010-1 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use Europe
IEC 61029 Safety of Transportable Motor-Operated Electric Tools Europe
IEC 61730-2 Photovoltaic (PV) Module Safety Qualification - Part 2 Requirements for Testing Europe
IEC 61813 Live Working - Care, Maintenance and In-service testing of Aerial Devices with Insulating Booms Europe
IEC 62052-11 Electricity Metering Equipment (AC) - General Requirements, Tests, and Test Conditions Europe
IEC 62353 Medical Electrical Equipment - Recurrent Test and Test After Repair of Medical Electrical Equipment Europe
IEC 62446 Grid Connected Photovoltaic Systems - Minimum requirements for System Documentation, Commissioning Tests and Inspection Europe
ITU-T K.20 Resistibility of Telecommunication Equipment Installed in a Telecommunications Centre to Overvoltages and Overcurrents Europe
ITU-T K.21 Resistibility of Telecommunication Equipment Installed in Customer premises to Overvoltages and Overcurrents Europe
JIS B8561 Vending Machines - Test Method Japan
JIS C9250 Microwave Ovens Japan
JIS T 0601-1 Electrical Safety Standard for Medical Devices Japan
TE-001, Para. 17 Telephone Surge Test Equipment: For the Lightning Protection Tests South Africa
TIA/EIA/IS-968 Telecommunications Telephone Terminal Equipment Technical Requirements for Connection of Terminal Equipment to the Telephone Network. (formerly known as FCC Part 68) U.S.
uL 492 Power-operated Radio Receiving Appliances U.S.
uL 746E Polymeric Materials - Industrial Laminates, Filament Wound Tubing, Vulcanized Fibre, and Materials Used In Printed-Wiring Boards (Section 19 covers requirements for conformal coatings used instead of electrical spacings to increase the dielectric withstand voltage between traces on a printed-wiring board.) U.S.