Features:
  • Display 4 digit LCD, 9999 counts, with annunciators, menu features and 41 segment bargraph.
  • High voltage capability, measures to 1500 Vdc and 1000 Vac
  • CAT IV 1000 V rated
  • IP67 rated, Specially sealed for environment/water resistance.
  • Drop-resistant housing and PCB mounting construction
  • Can measure capacitance, frequency and temperature
  • Superior 10,000 count resolution with bar graph
  • Magne-Grip holster, frees both hands for work
  • Including high voltage test leads with threaded alligator clips
  • Temperature measurement built-in
  • Digi-Glo bright backlight
  • Automatic Polarity Indication
  • Input overload indication OL, -OL.
  • Auto Automatic Power-Down



  Description

Rugged and reliable in harsh environments, the HD160C is designed for heavy use on a professional level. The meter is made from PCB mounting and thermoplastic construction to prevent dirt, grease and water vapor from causing internal damage or inaccurate readings. Sensitive components are shock-mounted for a drop resistance to at least eight feet.

Extended voltage measurement capability is 1500 V dc and 1000 V ac, and extended voltage ranges can withstand transients up to 12 kV.



  Models, Options, & Accessories


Model Description List Price Sale Price
HD160C Heavy Duty Digital Multimeter - Discontinued - suggested replacement: Amprobe HD160C



  Specifications

General Specifications
Display 4 digit LCD, 9999 counts, with annunciators, menu features and 41 segment bargraph.
Polarity Indication Automatic
Input overload indication OL, -OL.
Low Battery Indication B; less than 50 hours battery life remain, accuracy is no longer guaranteed
Display Update Rate 2/sec, nominal; 20/sec for bargraph.
Oper. Temp. 0 °C to +50 °C @ 0 to 75 % R.H.
Storage Temp. -20 °C to 60 °C @ 0 to 80 % RH, battery removed
Altitude 2000 meters - indoor use
Temperature coefficient 0.1 x (spec. accuracy)/°C (0 °C to 18 °C and 28 °C to 50 °C)
Fuse F 2 A/1500 V fuse (8 mm x 65 mm), I.R. 30 kA – Amprobe p/n FP700
Power Standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22
Auto Power-Down Meter powers down after approximately 30 minutes of inactivity. Not in Min/Max function.
Battery Life (typical) 150 hours, alkaline. Backlight usage consumes extra power and will decrease battery life significantly. Backlight auto-off after approx. 60 seconds.
Dimensions, without holster
(H x W x D)
200 x 102 x 59 mm (7.9 in x 4.0 in x 2.3 in)
Weight (incl. battery) 642 g (22 oz)
Accessories Heavy Duty CAT IV 1000 V Test leads with threaded alligator clips (TL1500), battery (installed), hex wrench (inside holster), Holster with Magne-Grip strap, Type K thermocouple probe (TP255), Temperature Adaptor (TA‑-1A) and User Manual.
Case material Reinforced, high-impact, fire retardant thermoplastic
Safety Meets EN 61010-1 CATIV1000V(1500VDCmax)ClassII,EN60529:IP67CAT IV 1000 V (1500 V DC max) Class II, EN 60529:IP67
EMC Meets EN 61326-1
Electrical Specifications
DC Volts Ranges 1000 mV, 10 V, 100 V, 1500 V
DC Volts Resolution 0.1 mV in 1000 mV range
DC Volts Accuracy ±(0.1 % rdg + 5 dgt)
DC Volts Input Impedance 10 MΩ
DC Volts CMRR >120 dB up to 1500 V dc
DC Volts NMRR >60 dB at 50 or 60 Hz
DC Volts OL Protection 1500 V dc or 1000 V ac rms
DC Volts Transient protection 12 kV impulse (1.2 ìS/50 ìS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V/1500V dc product. This product should not be used in installations
AC Volts True rms Ranges 1000 mV, 10 V, 100 V, 1000 V
AC Volts True rms Resolution 0.1 mV in 1000 mV range
AC Volts True rms Accuracy 1000 mV (45 Hz to 400 Hz) ± (1.2 % rdg + 10 dgt)
AC Volts True rms Accuracy 10 V, 100 V (45 Hz to 500 Hz) ± (1.2 % rdg + 10 dgt)
AC Volts True rms Accuracy 10 V, 100 V (500 Hz to 2 kHz) ± (2.0 % rdg + 10 dgt)
AC Volts True rms Accuracy 1000 V (45 Hz to 1 kHz) ± (2.0 % rdg + 10 dgt)
AC Volts True rms Input Impedance 10 MΩ
AC Volts True rms Conversion type True rms, ac coupled 5 % to 100 % of range
AC Volts True rms Crest factor ≤ 3
AC Volts True rms OL Protection 1500 V dc or 1000 V ac rms
Transient protection 12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV
DC Current Ranges 100 µA, 1000 µA, 10mA, 100mA, 400mA, 2A (Auto/Manual ranging)
DC Current Resolution 0.01µA in 100 ±A range
DC Current Accuracy 100 µA range ± (0.5% rdg + 10 dgts)
DC Current Accuracy 1000 µA to 400 mA ranges ± (0.5% rdg + 5 dgts)
DC Current Accuracy 2 A range ± (1.5% rdg + 10 dgts)
DC Current Input protection 2 A/1500 V fast blow ceramic fuse 8X65 mm on A input , FP700




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 



Live chat by BoldChat
Need help? We have a staff
of more than 30 people to help you.
Let us show you why over 100,000
customers choose Tequipment.NET