Wavetek Meterman HD160B Heavy Duty Multimeter

Click image to enlarge
Wavetek Meterman HD160B
|
|
Features:
- Capacitance measurements
- Exclusive, best “Digi-Glo” backlight
- Special sealing for environment and water proofing, IP67 and MIL-SPF-28800F rated
- Extra fusing and protection from accidental overloads
- Highest voltage measuring to 1500 V dc and 1000 V ac
- Unique live voltage Safety Tester
- CAT III 1000 V rated
|
Description
The Wavetek Meterman Heavy Duty (HD) 110B/115B/160B digital multimeters are construction for harsh conditions. These multimeters are built of fire-retardant plastic. All sensitive components are shock-mounted. Waterproof construction prevents dirt and moisture from entering the case. IP67 rated.
This series of multimeters has a feature that checks for live circuits, and indicates the presence of common power supply voltages (AC or DC, positive or negative). This multimeter eliminates the need for a separate voltage checker.
Included Accessories:
- Test leads
- Operator’s manual
- Holster
Optional accessories
- DC205B Deluxe Case
- DC207B Deluxe case with cavity for current clamp
- DL243C Basic test lead kit
- DL248C Deluxe test lead kit
- TL35A Test lead set with alligator clips
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| HD160B |
DMM Heavy Duty Autoranging - Discontinued - suggested replacement: Amprobe HD160C |
| HD115B |
DMM, Heavy Duty - Discontinued - suggested replacement: Amprobe HD160C |
| HD110B |
DMM, Heavy-Duty - Discontinued - suggested replacement: Amprobe HD110C |
| Model |
Accessories |
List Price |
Sale Price |
| DC205B |
Deluxe Hard Shell Case - Discontinued - suggested replacement: Amprobe DC205C |
| DC207B |
Deluxe Hard Shell Case, Large - Discontinued - suggested replacement: Amprobe DC207C |
| DL243C |
Basic Test Lead Kit - Discontinued - suggested replacement: Amprobe DL243D |
| DL248C |
Deluxe Test Lead Kit - Discontinued - suggested replacement: Amprobe DL248D |
| TL35A |
Test Lead With Alligator Clips - Ce - Discontinued - suggested replacement: Amprobe TL35B |
Specifications
| DC Voltage |
Ranges |
1 V, 10 V, 100 V, 1500 V |
| Accuracy 1 V |
± (0.25 % rdg + 6 dgts) |
| Accuracy 10 to 1500 |
± (0.1 % rdg + 2 dgts) |
| Resolution |
0.1 mV in 1 V range |
| Input Impedance |
10 MΩ |
| CMRR |
> 120 dB to 1500 V |
| NMRR |
> 60 dB at 50/60 Hz |
| AC Voltage |
Ranges |
10 V, 100 V, 1000 V |
| Accuracy 10 V (45 Hz to 10 kHz) |
± (1.5 % rdg + 5 dgts) |
| Accuracy 100 V range (2 V to 30 V) |
(45 Hz to 10 kHz) ± (1.5 % rdg + 3 dgts)
(10 kHz to 30 kHz) ±(2.5 % rdg + 5 dgts) |
| Accuracy 100V range (> 30 V) |
(45 Hz to 1 kHz) ± (1.5 % rdg + 3 dgts)1000 V
(45 Hz to 1 kHz) ± (1.5 % rdg + 3 dgts) |
| Resolution |
1 mV in 10 V range |
| Conversion Type |
True rms (ac coupled) |
| Input Impedance |
10 MΩ shunted by < 100 pF |
| Crest Factor |
1:1 through 5:1 |
| DC Current |
Ranges |
10 mA, 40 mA, 10 A |
| Accuracy |
± (0.75 % rdg + 5 dgts) |
| Voltage Burden mA ranges |
20 mV/mA |
| Voltage Burden 10 A range |
30 mV/A |
| Resolution |
10μ A in 10 mA range |
| AC Current (45 - 1 kHz) |
Ranges |
10 mA, 40 mA, 10 A |
| Accuracy All ranges |
± (1.75 % rdg + 5 dgts) |
| Voltage Burden |
See DC Current |
| Resolution |
10μ A in 10 mA range |
| Conversion Type |
True rms (ac coupled) |
| Crest Factor |
1:1 through 1:5 |
| Resistance |
Ranges |
1 kΩ, 10 kΩ, 100 kΩ,
1 MΩ, 10 MΩ, 40 MΩ |
| Accuracy 1 kΩ to 1 MΩ |
± (0.5 % rdg + 1 dgt) |
| Accuracy 10 MΩ |
± (1.0 % rdg + 1 dgt) |
| Accuracy 40 MΩ |
± (1.5 % rdg ± 2 dgts) |
| Test Current 1 kΩ |
1 mA |
| Test Current 10 kΩ |
150μ A |
| Test Current 100 kΩ |
15μ A |
| Test Current 1 MΩ |
1.5μ A |
| Test Current 10 MΩ, 40 MΩ |
0.2μ A |
| Response Time 1 kΩ |
1 sec |
| Response Time 10 kΩ to 40 MΩ |
3 sec |
| Resolution |
0.1 Ω in 1 kΩ range |
| Open Circuit Voltage 1 kΩ range |
3.0 V DC |
| Open Circuit Voltage All other ranges |
1.3 V DC |
| Diode Test |
Ranges |
1.0 V, 2.25 V |
| Accuracy |
± (1.0 % rdg ± 1 dgts) |
| Resolution |
0.1 mV in 1 V range |
| Short Circuit Current |
1.5 mA DC |
| Open Circuit Voltage |
3.0 V |
| Display Forward junction voltage |
| Continuity |
Continuity Threshold |
50 Ω ± 25 Ω |
| Response Time |
< 1 sec |
| Open Circuit Voltage |
3.0 V |
| Overload Protection |
DC Voltage |
1500 V DC |
| Transient Protection |
6 kV |
| AC Voltage <10 Hz |
400 V AC or 533 V peak; |
| AC Voltage > 10 Hz |
1000 V rms |
| Transient Protection |
6 kV for 10 ms |
| AC/DC Current mA input |
0.5 A/600 V (1000 AIC) |
| AC/DC Current 10A input |
15 A/600 V (100,000 AIC) |
| Resistance/Diode/Continuity All ranges |
500 V DC or V AC rms |
General specifications
| Display |
4 digit LCD, 4000/10000 counts |
| Display Update Rate |
2/sec, nominal; bargraph 20/sec |
| Power |
9 V battery, NEDA 1604, JIS 006P, IEC 6F22 |
| Battery Life |
450 hours |
| Operating Temperature |
0 ºC to + 50 ºC, 0 to 70 % R.H. |
| Storage Temperature |
- 40 ºC to 70 ºC, 0 to 95 % R.H. battery removed |
| Dimensions (HxWxD) |
224 x 99 x 58 mm (8.8" x 3.9" x 2.3") |
| Weight (incl. battery) |
644 grams (1.42 lb) |
|