Our agents are available:
9:00 AM - 6:00 PM EST
Wavetek Meterman HD110C Digital Multimeter - Heavy Duty
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   



Wavetek Meterman HD110C Digital Multimeter - Heavy Duty




Click image to enlarge

Amprobe HD110C


Features:
  • 3-1/2 digit LCD
  • High voltage capability: 1500 V dc/1000 V ac
  • CAT IV 1000 V rated
  • IP67 rated
  • Resistant casing for protection against environment and water.
  • Drop-resistant housing and PCB mounting construction
  • Magne-Grip holster
  • High voltage test leads with threaded alligator clips
  • Display capability - 1999 counts with annunciators
  • Automatic Polarity Indication
  • Low Battery Indicator
  • Standard 9 V battery, NEDA 1604, JIS 006P,IEC 6F2
  • High impact, flame retardant thermoplastic case included



  Description

The Wavetek Meterman HD110C Digital Multimeter is designed for heavy Duty use in industrial conditions. These meters are built of flame-retardant plastic and all sensitive components are shock-mounted, as well as waterproof construction preventing dirt and water from entering the case.

Thermoplastic and PCB mounting make the HD110C resistant to grease and chemical spills, with sensitive components protected from falls to at least eight feet. The HD110C provides extended voltage measurement capability of 1500 V dc and 1000 V ac, with voltage ranges withstanding transients up to 12 kV.



  Models, Options, & Accessories


Model Description List Price Sale Price
HD110C Heavy-Duty Digital Multimeter - Discontinued - suggested replacement: Amprobe HD110C



  Specifications

General Specifications
Display 3-1/2 digit LCD, 1999 counts, with annunciators and menu features
Polarity Indication Automatic
Input overload indication 1
Low Battery Indication < 50 hours battery life remain, accuracy is no longer guaranteed
Display Update Rate 2.5/sec, nominal
Oper. Temp. 0 °C to +50 °C, (< 75 % R.H.)
Storage Temp -20 °C to 60 °C, 0 to 80 % RH, battery removed
Temperature coefficient 0.1 x (spec. accuracy)/°C (0 ° to 18 °C and 28° to 50 °C) all functions and ranges except for mVDC
0.3 x (spec. accuracy)/°C (0 ° to 18 °C and 28° to 50 °C) for mVDC
Altitude Up to 2000 m - indoor use
Fuse F 2 A/1500 V fuse (8 mm x 65 mm), I.R. 30 kA – Amprobe p/n FP700
Power Standard 9 V battery, NEDA 1604, JIS 006P,IEC 6F22
Auto Power-Down Meter powers down after approx. 30 min. of inactivity.
Battery Life 250 hours typical with carbon-zinc, 500 hours typical with alkaline
Dimensions, with holster (H x W x D) 200 x 102 x 59 mm (7.9 in x 4.0 in x 2.3 in)
Weight (incl. battery) 642 g (20 oz)
Accessories Heavy Duty CAT IV 1000 V Test leads with threaded alligator clips (TL1500), battery (in instrument), hex wrench in holster, Magne-Grip flex strap and User Manual
Case material Flame retardant, high-impact thermoplastic
Safety Meets EN 61010-1 CAT IV 1000 V (1500 V DC max) Class II, EN 60529:IP67
EMC Meets EN 61326-1
Resistance Ranges 200 O, 2 kO, 20 kO, 200 kO, 2 MO, 20 MO
DC Volts Ranges 200 mV, 2 V, 20 V, 200 V, 1500 V
DC Volts Resolution 0.1 mV
DC Volts Accuracy All ranges ±(0.1 % rdg+2 dgts)
DC Volts Input Impedance 10 MÙ
DC Volts OL Protection 1500 V dc/1000 V ac rms
DC Volts Transient Protection 12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV
AC Volts (45 Hz to 2 kHz) Ranges 200 mV, 2 V, 20 V, 200 V, 1000 V
AC Volts (45 Hz to 2 kHz) Resolution 0.1 mV
AC Volts (45 Hz to 2 kHz) Accuracy 200 mV to 200 V (45-500 Hz) ±(0.8 % rdg+4 dgts),
AC Volts (45 Hz to 2 kHz) Accuracy 200 mV to 200 V (500 Hz-2 kHz) ±(1.5 % rdg+5 dgts)
AC Volts (45 Hz to 2 kHz) Accuracy 1000 V (50-60 Hz) ±(0.8 % rdg+4 dgts)
AC Volts (45 Hz to 2 kHz) Accuracy 1000 V (60-500 Hz) ±(1.5 % rdg+5 dgts)
AC Volts (45 Hz to 2 kHz) Input Impedance 10 MÙ
AC Volts (45 Hz to 2 kHz) OL Protection 1500 V dc/1000 V ac rms
AC Volts (45 Hz to 2 kHz) Transient Protection 12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV.
DC Current Ranges 200 µA, 2 mA, 20 mA, 200 mA, 2 A
DC Current Resolution 0.1 µA
DC Current Accuracy 200 µA to 20 mA ±(0.5 % rdg+2 dgts)
DC Current Accuracy 200 mA to 2 A ±(1.0 % rdg+2 dgts)
DC Current Voltage Burden 250 mV max. (1 mV/1 µA on 200 µA Range)
DC Current Voltage Burden 100 mV/1 mA on 2 mA Range)
DC Current Voltage Burden (10 mV/1 mA on 20 mA Range)
DC Current Voltage Burden (1.5 mV/1 mA on 200 mA Range)
DC Current Voltage Burden (500 mV/1 A on 2 A Range)
DC Current OL Protection A Input (F 2 A/1500 V, size 8 x 65 mm IR fast blow ceramic) (FP 700)



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  