| DC Voltage |
Ranges |
200 mV, 2 V, 20 V, 200 V, 1500 V |
| Accuracy |
± (0.1 % rdg + 1 dgt) |
| Resolution |
0.1 mV in 200 mV range |
| Input Impedance |
10 MΩ |
| NMRR |
> 60 db |
| CMRR |
> 60 db (49 Hz) |
| AC Voltage |
Ranges |
200 mV, 2 V, 20 V, 200 V, 1000 V |
| Accuracy 200 mV, 2 V, 20 V: |
45 Hz-2 kHz ±
(0.75 % rdg + 3 dgts)2 kHz-5 kHz ±
(1.5 % rdg + 5 dgts) |
| Accuracy 200 V: |
45 Hz-1 kHz ±
(0.75 % rdg + 3 dgts) |
| Accuracy 1000 V: |
45 Hz-500 Hz ±
(0.75 % rdg + 3 dgts)500 Hz-1000 Hz ±
(1.5 % rdg + 5 dgts) |
| Resolution |
0.1 mV in 200 mV range |
AC Conversion Average sensing,
rms indicating Input Impedance |
10 MΩ/75 pF |
| DC Current |
Ranges |
200 μA, 2 mA, 20 mA, 200 mA, 2 A, l0 A |
| Accuracy 200 μA-2 A: |
± (0.35 % rdg + 1 dgt) |
| Accuracy 10 A: |
±(1.0 % rdg + 1 dgt) |
| Resolution |
0.1 μA in 200 μA range |
| Burden Voltage 200 μA range: |
1 mV/1 μA |
| Burden Voltage 2 mA range: |
100 mV/1 mA |
| Burden Voltage 20 mA range: |
10 mV/1 mA |
| Burden Voltage 200 mA range: |
1.2 mV/1 mA |
| Burden Voltage 2 A range: |
300 mV/1 A |
| Burden Voltage 10 A range: |
37 mV/1 A |
| AC Current |
Ranges |
200 ±A, 2 mA, 20 mA, 200 mA, 2 A, l0 A |
| Accuracy 200 ±A-2 A (45 Hz-2 kHz): |
± (0.9 % rdg + 3 dgt) |
| Accuracy 10 A (45-400 Hz): |
± (1.5 % rdg + 3 dgt) |
| Resolution |
0.1 ±A in 200 ±A range |
AC Conversion Type Average sensing, rms indicating Burden Voltage |
See DC Current |
| Resistance |
Ranges |
200 Ω, 2 kΩ, 20 kΩ,
200 kΩ, 2 MΩ, 20 MΩ |
| Accuracy 200 Ω-2 MΩ: |
± (0.2 % rdg + 1 dgt) |
| Accuracy 20 MΩ: |
± (l.0 % rdg + 1 dgt) |
| Resolution |
0.1 Ω in 200 Ω range |
| Max Open Circuit Voltage 200 Ω: |
3 V |
| Max Open Circuit Voltage Other: |
0.3 V |
| Max In-Range Voltage |
200 mV |
| Max Test Current |
2.5 mA |
| Diode Test |
Range |
0 to 2 V |
| Accuracy |
± (6.0 % rdg + 2 dgts) |
| Test Current |
2 mA ± 20 % |
| Display Response |
1 sec. |
| Continuity |
Tone and Visual Signal |
< 80 Ω |
| Overload Protection |
Transient Protection
ACV/DCV any Range |
3 kV for l0 μs |
| DCV Range |
1500 V DC or pk ac any range |
| ACV Ranges |
l000 Vrms/1500 V pk ac or250 V DC (5 sec max. above 450 V rms on 200 mV range) |
| Current Range 200 μA-2 A ranges: |
2 A/600 V fuse (3000 A interrupt rating) |
| Current Range 10 A range: |
l5 A/600 V fuse (100 kA interrupt rating) |
| Resistance/Diode/Continuity Ranges |
600 V DC or rms AC |