Wavetek Meterman 38XR Digital True RMS

Click image to enlarge
Wavetek Meterman 38XR
|
|
Features:
- Frequency to 10 MHz, capacitance to 400 μF temperature to 2372 ºF
- Duty cycle, dBm and 4 to20 mA loop current test
- 1000 V/750 V dc/ac True RMS, ac + dc input
- 10 Amps ac/dc, fully safety fused
- Resistance to 40 MΩ
- Continuity beeper
- Min/Max, Average, Relative, Peak, and Data Hold
- Bright blue backlight
- Auto power off to save battery life
- RS232 Output for measurement recording
- Separate door for easy battery and fuse access
- CAT IV 600 V, CAT III 1000 V, highest rating
- Magne-Grip Holster with magnetic hanging strap
Warranty: 3 years
|
Description
|
The 38XR is a true RMS digital
multimeter with optical PC interface. The XR series of multimeters
is designed for electronic, electrical, plant maintenance and
HVAC use. Three models are true-rms: 34XR,
37XR and 38XR. Two are average
responding, 30XR and 33XR.
For designing and troubleshooting electronics, industrial automation
and control systems, the 38XR deliver the highest safety rating
available – CAT IV 600 V and CAT III 1000 V. The features include
temperature, capacitance, frequency, 4-20mA loop current percentage,
backlight and PC interface.
| Magne-Grip
Holster with magnetic hanging strap |
|
All
five meters have a Magne-Grip Holster with magnetic hanging
strap that secures the meter to a convenient steel surface,
freeing both hands for work.
Many DMM users find they need a “third hand” when taking a
measurement with their meter. We designed the Magne-Grip
holster to protect the meter and provide the “third hand”
DMM users need. An innovative magnetic hanging strap secures
the meter to a convenient steel surface, freeing both hands
for work. |
Optional
RS232 cable and software, 38-SW |
|
With
the addition of 38SW software
and RS232 cable, the 38XR can be used for real-time data
acquisition using any industry standard Windows® PC.
- Real-time
data acquisition software logs and displays data from
all 38XR measurement functions
- Stores
data for retrieval or for further analysis
- Exports
data for use in Excel® or other programs
- Supports
Windows® 98, NT, XP and their variants
|
Included Accessories:
- Test leads with threaded alligator clips (TL36)
- temperature adaptor (XR-TB)
- Type K thermocouple probe(TP255)
- 9 V battery (installed)
- Magne-Grip Holster with magnetic hanging strap
- spare fuse
- operators manual
Optional accessories
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| 38XR |
Prof Dmm True Rms W Optical Pc Interface - Discontinued - suggested replacement: Amprobe 38XR-A |
| 37XR |
Prof Dmm True Rms W Component Logic Test - Discontinued - suggested replacement: Amprobe 37XR-A |
| 34XR |
Prof Dmm True Rms W Temperature & Backlight - Discontinued - suggested replacement: Amprobe 34XR-A |
| Model |
Accessories |
List Price |
Sale Price |
| VC221A |
Vinyl Case 200 Series/Hd, B Series - Discontinued - suggested replacement: Amprobe VC221B |
| DL248C |
Deluxe Test Lead Kit - Discontinued - suggested replacement: Amprobe DL248D |
| DC205B |
Deluxe Hard Shell Case - Discontinued - suggested replacement: Amprobe DC205C |
| DC207B |
Deluxe Hard Shell Case, Large - Discontinued - suggested replacement: Amprobe DC207C |
| HV231-10 |
Hv Probe 10 Megohm - Discontinued - suggested replacement: Amprobe HV231-10A |
| TP254 |
Immersion Temperature Probe - Discontinued - suggested replacement: Amprobe TP254A |
| 38-SW |
Rs232 Data Software/Cable For 38Xr Dmm - Discontinued - suggested replacement: Amprobe 38SW-A |
Specifications
| DC Voltage |
Ranges |
1000mV,10V,100V,1000V |
| Accuracy all ranges: |
± (0.25 % rdg + 5 dgt) |
| Resolution |
100 µV |
| AC Voltage (45 Hz to 2 kHz) True RMS |
Ranges |
1000 mV, 10 V, 100 V, 750 V |
| Accuracy 750 V range: |
45 to 1 kHz: ± (2.0 % rdg + 10 dgts) |
| Accuracy All other ranges, 45 to 500 Hz: |
± (1.2 % rdg + 10 dgts) |
| Accuracy All other ranges, 500 to 2 kHz: |
± (2.0 % rdg + 10 dgts) |
| AC coupled |
True RMS specified from 5% to 100 % of range |
| AC + DC Voltage (45 Hz to 2 kHz) |
Ranges |
1000 mV, 10 V, 100 V, 750 V |
| Accuracy 750 V range:45 to 1 kHz: |
± (2.5 % rdg + 10 dgts) |
| Accuracy All other ranges, 45 to 500 Hz: |
± (1.5 % rdg + 10 dgts) |
| Accuracy All other ranges, 500 to 2 kHz: |
± (2.5 % rdg + 10 dgts) |
| Resolution |
100 µV |
| DC coupled |
True RMS specified from 5 % to 100 % of range |
| DC Current |
Ranges |
100 µA, 1000 uA, 10 mA, 100 mA, 400 mA, 10 A |
| Accuracy 100 µA range: |
± (0.5 % rdg + 10 dgt) |
| Accuracy 1000 uA to 400 mA ranges: |
± (0.5 % rdg + 5 dgts) |
| Accuracy 10 A range: |
±(1.5 % rdg + 10 dgt) |
| Resolution |
0.01 µA |
| AC Current (True RMS) ( AC + DC) (45 Hz – 1kHz) |
Ranges |
100 µA, 1000 µA, 10 mA, 100 mA, 400 mA, 10 A |
| Accuracy 100 µA to 100 mA ranges: |
± (1.5 % rdg + 20 dgts) |
| Accuracy 400 mA range: |
± (2.0 % rdg + 10 dgts) |
| Accuracy 10 A range: |
± (2.5 % rdg + 20 dgts) |
| Resolution |
0.01 µA |
| AC coupled |
True RMS specified from 5 % to 100 % of range |
| AC + DC Accuracy 100 µA to 400 mA ranges: |
± (2.0 % rdg + 20 dgts) |
| AC + DC Accuracy 10 A range: |
± (3.0 % rdg + 20 dgts) |
| AC + DC: |
AC coupled True RMS specified from 10 % to 100 % of range |
| Resistance |
Ranges |
1000 Ω, 10 kΩ, 100 kΩ, 1000 kΩ, 10 MΩ, 40 MΩ |
| Accuracy 1000 Ω to 1000 kΩ ranges: |
± (0.5 % rdg + 8 dgts) |
| Accuracy 10 MΩ range: |
± (1.0 % rdg + 10 dgts) |
| Accuracy 40 MΩ range: |
± (2.0 % rdg + 10 dgts) |
| Resolution |
100 mΩ |
| Capacitance |
Ranges |
40 nF, 400 nF, 4 µF, 40 µF, 400 µF |
| Accuracy 40 nF, 400 µF ranges: |
± (3.0 % rdg + 10 dgts) |
| Accuracy 400 nF to 40 µF ranges: |
± (3.0 % rdg + 5 dgts) |
| Resolution |
0.01 nF |
| Temperature |
Ranges |
-20 ºC to 1300 ºC, -4 ºF to 2372 ºF |
| Accuracy -20 ºC to 10 ºC: |
± (2.0 % rdg + 4 ºC ) |
| Accuracy 10 ºC to 200 ºC: |
± (1.0 % rdg + 3 ºC ) |
| Accuracy 200 ºC to 1300 ºC: |
± (2.0 % rdg + 2 ºC ) |
| Accuracy -4 ºF to 50 ºF: |
± (2.0 % rdg + 8 ºF) |
| Accuracy 50 ºF to 400 ºF: |
± (1.0 % rdg + 6 ºF) |
| Accuracy 400 ºF to 2372 ºF: |
± (2.0 % rdg + 4 ºF) |
| Resolution |
1 ºC, 1 ºF |
| Frequency |
Ranges |
100 Hz, 1000 Hz, 10 kHz, 100 kHz, 1000 kHz, 10 MHz |
| Accuracy all ranges: |
± (0.1% rdg + 5 dgts)Resolution 0.01 Hz |
| Duty Cycle |
Ranges |
0 to 90 % |
| Accuracy 5 V logic: |
± (2.0% rdg + 10 dgts) |
| Resolution |
0.01 % |
| Frequency Range 0 % to 10 %: |
40 Hz to 990 Hz |
| Frequency Range 10 % to 90 %: |
40 Hz to 20 kHz |
| 4 - 20 mA DC Current Test |
Range |
0 – 100 % |
| Accuracy |
± (0.5 % + 5 dgts) |
| Resolution |
0.01 % |
| DBm |
Ranges |
-13 dBm to + 50 dBm |
| Accuracy 45 Hz to 5 kHz: |
± (0.7 dB + 8 dgts) |
| Accuracy 5 kHz to 10 kHz: |
± (2.5 dB + 8 dgts) |
| Resolution |
0.01 dBm |
| Continuity |
Audible Indication |
< 40 Ω |
| Diode Test |
Test Current |
0.5 mA (approximate) |
| Open Circuit Volts |
3.0 V dc typical |
| Peak |
AC Volts Accuracy 100 V, 750 V ranges: |
± (3.0 + 200 dgts) |
| AC Volts Accuracy 1000 mV, 10 V ranges: |
unspecified AC Current ± (3.0 + 200 dgts) |
| Overload Protection |
AC/DC Voltage |
1000 V dc or 750 V ac rms |
| AC/DC Current µA/mA input: |
F0.5 A /1000 V fast-blow ceramic 6.3 x 32 mm |
| AC/DC Current 10A input: |
F10 A /1000V fast-blow ceramic 10 x 38 mm |
General specifications
| Autoranging Display: |
4-3/4 digit LCD, 10,000 counts with 41-segment analog bar graph |
| Display Update Rate |
2/sec, nominal |
| Power Battery |
9 V NEDA 1604, JIS 006P, IEC 6F22 |
| Battery Life |
150 hrs typical (alkaline) frequent use of backlight will decrease battery life |
| Operating Temperature |
0 ºC to 45 ºC at < 70% R.H |
| Storage Temperature |
-20 ºC to 60 ºC, 0 to 80 % R.H. with battery removed from meter |
| Temperature Coefficient |
0.1 x (specified accuracy) per ºC
(0 ºC to 18 ºC , 28 ºC to 45 ºC) |
| Altitude |
2000 m) 6562 ft |
| Dimensions: |
7.8" x 3.55" x 2.4" (196 x 96 x 60 mm) |
| Weight (without holster, includingbattery) |
1 lb (400 gr) |
| Voltage AC |
750 TRMS AC + DC |
| Voltage DC |
1000 V |
| mV AC |
TRMS AC + DC |
| Basic DC Accuracy |
0.25% |
| DC Current, fused |
10 A |
| AC Current, fused |
10 A TRMS |
| Resistance |
40MΩ |
| Capacitance |
400µF |
| Frequency |
10 MHz |
| Temperature |
2372 ºF/1300 ºC |
|