company logo Wavetek Meterman 35XP 4000 Count Autoranging Multimeter
     Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.  
 
 
 



Wavetek Meterman 35XP 4000 Count Autoranging Multimeter




Click image to enlarge

 Wavetek Meterman 35XP

Features:
  • VolTect™ Non-Contact Voltage Detector
  • Magne-Grip™ Holster
  • 4000-count resolution
  • Temperature measurement capability to 1000 °C/1832 °F (Type K thermocouple included)
  • 750 V ac/1000 V dc – highest voltage rating in this class of meter
  • Capacitance for motor run/start capacitance tests
  • 0.1 μA resolution for flame sensor testing
  • Frequency to 20 MHz
  • Resistance to 20 MΩ
  • Continuity beeper
  • Data Hold freezes display
  • MSRP $79.95 (US)
Warranty: One-year, no-hassle


  Description

The Meterman XP series of multimeters combine features and accuracy in a small device. Each XP multimeter has built-in non-contact voltage (NCV) detection, Magne-Grip holster and CAT III safety ratings. Three models to choose from:
  1. 5XP – 2000-count manual ranging meter for residential and commercial electrical use, and general purpose troubleshooting.
  2. 15XP – 2000-count autoranging with logic test for electronic and field service applications.
  3. 35XP – 4000-count autoranging with temperature and capacitance for industrial, HVAC and electronic applications.


Included accessories:
  • One pair test leads TL245
  • Fuse 2 A/1000 V (installed) P/N FP200
  • 9 V battery (installed) and operatinginstructions holster
  • Magnet strap
  • Temperature adapter
  • K-type thermocouple



  Models, Options, & Accessories


Model Description List Price Sale Price
35XP Compact Dmm With Temp, Freq, Capacitance - Discontinued - suggested replacement: Amprobe 35XP-A
5XP Compact Dmm With Non-Contact Voltage - Discontinued - suggested replacement: Amprobe 5XP-A
15XP Compact Dmm With Ncv And Logic Test - Discontinued - suggested replacement: Amprobe 15XP-A



  Specifications

DC Volts Ranges 400 mV, 4 V, 40 V, 400 V, 1000 V
Resolution 100 μV
Accuracy ±(0.5 % rdg + 1 dgt)
Input impedance 400 mV: >100 MΩ
Input impedance 4 V: 10 MΩ
Input impedance 40 V ~ 1000 V: 9.1 MΩ
Overload protection 1000 VDC or 750 VAC rms
AC Volts (45 Hz - 500 Hz) Ranges 400 mV, 4 V, 40 V, 400 V, 750 V
Resolution 100 μV
Accuracy 45 Hz ~ 100 Hz on 400 mV range ± (1.5 % rdg + 5 dgts)
Accuracy on 4 V to 750 V ranges ± (1.5 % rdg + 5 dgts)
Input impedance 400 mV: >100 MΩ
Input impedance 4 V: 10 MΩ
Input impedance 40 V ~ 1000 V: 9.1 MΩ
Overload protection 1000 VDC or 750 VAC rms
DC Current Ranges 400 μA, 4000 μA,
40 mA, 400 mA, 2 A
Resolution 0.1 μA
Accuracy on 400 μA to 400 mA ranges ± (1.0 % rdg + 2 dgt)
Accuracy on 2 A range ± (2.0 % rdg + 3 dgts)
Input protection 2 A/1000 V fast blow ceramic fuse 6.3_32 mm on A input
Burden voltage 500 mV max.
(2 V max. on 4 mA, 400 mA ranges)
AC Current (45 Hz - 500 Hz) Ranges 400 μA, 4000 μA,
40 mA, 400 mA, 2 A
Resolution 0.1 μA
Accuracy on 400 μA to 400 mA ranges ± (1.5 % rdg + 5 dgts)
Accuracy on 2 A range ± (2.5 % rdg + 5 dgts)
Input protection 2 A/1000 V fast blow ceramic fuse
6.3 x 32 mm on A input
Burden voltage 500 mV max.
(2 V max. on 4 mA, 400 mA ranges)
Resistance Ranges 400 Ω, 4 kΩ, 40 kΩ,
400 kΩ, 4 MΩ, 40 MΩ
Resolution 100 mΩ
Accuracy on 400 Ω to 4 MΩ ranges ± (1.0 % rdg + 4 dgts)
Accuracy on 40 MΩ range ± (2.0 % rdg + 5 dgts)
Open circuit volts 0.45 V dc typical,
(-1.2 Vdc on 400 Ω range)
Overload protection 1000 VDC or 750 VAC rms
Capacitance Ranges 4 nF, 40 nF, 400 nF, 4 μF,
40 uF, 400 uF, 4 mF
Resolution 1 pF
Accuracy on 4 nF to 4 μF ranges ± (5.0 % rdg + 30 dgts)
Accuracy on 40 μF to 400 μF ranges ± (5.0 % rdg + 5 dgts)
Accuracy on 4 mF ranges ± (5.0 % rdg + 15 dgts)
Test voltage < 1 V
Test frequency on 4 nF to 40 μF ranges 1.3 Hz
Test Frequency on 400 μF, 4 mF ranges 0.7 Hz
Input protection 2 A/1000 V fast blow ceramic fuse
6.3 x 32 mm on A input
Temperature Ranges -20 µC ~ 1000 µC,
-4 µF ~ 1832 µF
Resolution 0.1 µC, 0.1 µF
Accuracy -20 µC ~ 10 µC ± (2.0 % rdg + 4 µC)
Accuracy 10 µC ~ 200 µC ± (1.0 % rdg + 3 µC)
Accuracy 200 µC ~ 1000 µC ± (3.0 % rdg + 2 µC)
Accuracy -4 µF ~ 50 µF ± (2.0 % rdg + 8 µF)
Accuracy 50 µF ~ 400 µF ± (1.0 % rdg + 6 µF)
Accuracy 400 µF ~1832 µF ± (3.0 % rdg + 4 µF)
Overload protection 1000 VDC or 750 VAC rms
Frequency Ranges 4 k, 40 k, 400 k, 4 M, 40 MHz
Resolution 1 Hz
Accuracy ± (0.1 % rdg + 3 dgts)
Sensitivity 10 Hz ~ 4 MHz: >1.5 V rms
Sensitivity 4 MHz ~ 40 MHz: >2 V rms, < 5 V rms
Minimum pulse width > 25 ns
Duty cycle limits > 30 % and < 70 %
Overload protection 1000 VDC or 750 VAC rms
Continuity Audible indication Less than 25 Ω
Response time 100 ms
Overload protection 1000 VDC or 750 VAC rms
Diode Test Test current 1.2 mA (approximate)
Accuracy ± (1.5 % rdg + 3 dgts)
Resolution 1 mV
Open circuit volts 3.0 dc typical
Overload protection 1000 VDC or 750 VAC rms
Non-Contact Voltage Indicator Sense voltage 70 V to 600 VAC beeper chirps and big
bright red LED comes on, works on all ranges

  General specifications
Display 3-3/4 digit liquid crystal display
(LCD) with a maximum reading of 3999
Polarity Automatic, positive implied, negative polarity indication
Overrange (OL) or (-OL) is displayed
Zero Automatic
Low battery indication The low battery icon is displayed when the
battery voltage drops below the operating level
Auto power off Approx. 10 minutes
Measurement rate 2 times per second, nominal
Operating environment 0 ºC to 50 ºC at <70 % R.H.
Storage temperature -20 ºC to 60 ºC, 0 to 80 % R.H.
with battery removed from meter
Accuracy Stated accuracy at 23 ºC ± 5 ºC,
<75 % relative humidity
Temperature coefficient 0.1 x (specified accuracy) per ºC.
(0 ºC to 18 ºC, 28 ºC to 50 º C)
Altitude 6561.7 feet (2000 M)
Power Single standard 9-volt battery,
NEDA 1604, JIS 006P, IEC 6F22
Battery life 150 hours typical with carbon-zinc,
300 hours typical with alkaline
Dimensions 155 mm (H) x 72 mm (W) x 32 mm (D)
Weight Approx. 400 g including battery
Safety Designed to meet IEC 1010-1, Rev-2 CAT I 1000V, CAT II 600V,CAT III 300V, class 2 and pollution degree 2 indoor use. Complies withCE and CSA 22.2 No. 1010-1 requirements.
Auxiliary Features Data hold Freeze the latest reading on the display Range Execute manual range mode AUTO power off. After auto power off, press any button to restart the meter, and the last reading of measurement will be maintained in the display. A jack Input warning detects wrong connection




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 



Live chat by BoldChat
Need help? We have a staff
of more than 30 people to help you.
Let us show you why over 100,000
customers choose Tequipment.NET