Wavetek Meterman 34XR DMM True RMS

Click image to enlarge
Wavetek Meterman 34XR
|
|
Features:
- Frequency to 40 MHz, temperature to 1832 ºF, capacitance to 4000 µF
- Input warning tone whentest leads are in wrong jack
- 1000 V/750 V dc/ac
- 10 Amps ac/dc, fully safety fused
- Resistance to 40 MΩ
- Continuity beeper
- Min/Max, Data Hold and Range Lock
- Auto power off to save battery life
- Separate door for easy battery and fuse access
- Magne-Grip Holster with magnetic hanging strap
- CAT III 600 V, CAT II 1000 V rated
- UL (CULUS) listed
Warranty: 3 years
|
Description
The 34XR is a true rms with temperature and backlight. Models 33XR and 34XR designed for maintenance, repair and installation of electrical and electro-mechanical equipment. Ideal for contractors and field service technicians. The XR series of multimeters is designed for electronic, electrical, plant maintenance and HVAC use. Three models are true-rms: 34XR, 37XR and 38XR. Two are average responding, 30XR and 33XR.
All five meters have a Magne-Grip Holster with magnetic hanging strap that secures the meter to a convenient steel surface, freeing both hands for work.
Magne-Grip Holster with magnetic hanging strap
|
Many DMM users find they need a “third hand” when taking a measurement with their meter. We designed the Magne-Grip™ holster to protect the meter and provide the “third hand” DMM users need. An innovative magnetic hanging strap secures the meter to a convenient steel surface, freeing both hands for work.
|
Included Accessories:
- Test leads with threaded alligator clips (TL36)
- 9 V battery (installed)
- Magne-Grip Holster with magnetic hanging strap (H2-XR)
- Temperature adapter (XR-TB)
- Type K thermocouple probe (TP255)
- spare fuse
- operators manual
Optional accessories
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| 34XR |
Prof Dmm True Rms W Temperature & Backlight - Discontinued - suggested replacement: Amprobe 34XR-A |
| 37XR |
Prof Dmm True Rms W Component Logic Test - Discontinued - suggested replacement: Amprobe 37XR-A |
| 38XR |
Prof Dmm True Rms W Optical Pc Interface - Discontinued - suggested replacement: Amprobe 38XR-A |
| Model |
Accessories |
List Price |
Sale Price |
| VC221A |
Vinyl Case 200 Series/Hd, B Series - Discontinued - suggested replacement: Amprobe VC221B |
| DL248C |
Deluxe Test Lead Kit - Discontinued - suggested replacement: Amprobe DL248D |
| DC205B |
Deluxe Hard Shell Case - Discontinued - suggested replacement: Amprobe DC205C |
| HV231-10 |
Hv Probe 10 Megohm - Discontinued - suggested replacement: Amprobe HV231-10A |
| TP254 |
Immersion Temperature Probe - Discontinued - suggested replacement: Amprobe TP254A |
Specifications
| DC Voltage |
Ranges |
400 mV, 4 V, 40 V, 400 V, 1000 V |
| Accuracy all ranges: |
± (0.5 % rdg + 1 dgt) |
| Resolution |
100 μV |
| AC Voltage (45 Hz to 2 kHz) True RMS |
Ranges |
400 mV, 4 V, 40 V, 400 V, 750 V |
| Accuracy 400 mV range, 45 to 100 Hz: |
± (1.2 % rdg + 8 dgts) |
| Accuracy 750 V range: 45 to 1 kHz: |
± (2.0 % rdg + 8 dgts) |
| Accuracy All other ranges, 45 to 500 Hz: |
± (1.2 % rdg + 8 dgts) |
| Accuracy All other ranges, 500 to 2 kHz: |
± (2.0 % rdg + 8 dgts) |
| Resolution |
100 μV |
| AC coupled |
True RMS specified from 5 % to 100 % of range |
| DC Current |
Ranges |
400 μA, 4 mA, 40 mA, 300 mA, 10 A |
| Accuracy 400 μA to 300 mA ranges: |
± (1.0 % rdg + 1 dgt) |
| Accuracy 10 A range: |
± (2.0 % rdg + 3 dgts) |
| Resolution |
0.1 μA |
| AC Current (45 Hz to 1 kHz) True RMS |
Ranges |
400 μA, 4 mA, 40 mA, 300 mA, 10 A |
| Accuracy 400 μA to 300 mA ranges: |
± (1.5 % rdg + 8 dgts) |
| Accuracy 10 A range: |
± (2.5 % rdg + 10 dgts) |
| Resolution |
0.1 μA |
| Resistance |
Ranges |
400 Ω, 4 kΩ, 40 kΩ, 400 kΩ, 4 MΩ, 40 MΩ, |
| Accuracy 400, 4 k, 40 k, 400 k, 4 MΩ ranges: |
± (1.0 % rdg + 4 dgts) |
| Accuracy 40 MΩ range: |
± (2.0 % rdg + 5 dgts) |
| Resolution |
100 mΩ |
| Capacitance |
Ranges |
4 μF, 40 μF, 400 μF, 4000 μF |
| Accuracy 4 μF range: |
± (5.0 % rdg + 10 dgts) |
| Accuracy 40 μF, 400 uF ranges: |
± (5.0 % rdg + 5 dgts) |
| Accuracy 4000 μF range: |
± (5.0 % rdg + 15 dgts) |
| Resolution |
1 nF |
| Temperature |
Ranges |
-20 ºC to 1000 ºC, -4 ºF to 1832 ºF |
| Accuracy -20 ºC to 10 ºC: |
± (2.0 % rdg + 4 ºC ) |
| Accuracy 10 ºC to 200 ºC: |
± (1.0 % rdg + 3 ºC ) |
| Accuracy 200 ºC to 1000 ºC: |
± (3.0 % rdg + 2 ºC ) |
| Accuracy -4 ºF to 50 ºF: |
± (2.0 % rdg + 8 ºF) |
| Accuracy 50 ºF to 400 ºF: |
± (1.0 % rdg + 6 ºF) |
| Accuracy 400 ºF to 1832 ºF: |
± (3.0 % rdg + 4 ºF) |
| Resolution |
1 ºC, 1 ºF |
| Frequency |
Ranges 4 kHz, 40 kHz, 400 kHz, 4 MHz, 40MHz Accuracy all ranges: ± (0.1 % rdg + 3 dgts) Resolution 1 Hz |
4 kHz, 40 kHz, 400 kHz, 4 MHz, 40MHz |
| Duty Cycle |
Ranges |
0 to 90 % |
| Accuracy 5 V logic: |
± (2.0 % rdg + 5 dgts) |
| Frequency Range |
40 Hz to 20 kHz |
| Continuity |
Audible Indication |
< 35 Ω |
| Diode test |
Test Current |
1.2 mA (approximate) |
| Open Circuit Volts |
3.0 V dc typical |
| Overload Protection |
AC/DC Voltage All ranges |
1000 V dc or 750 V ac rms |
| AC/DC Current μA/mA input: |
0.315 A /1000 V fast-blow ceramic (6.3 x 32 mm) |
| AC/DC Current 10 A input: |
10 A /1000 V fast-blow ceramic 10 x 38 mm (10 A for 4 minutes maximum followed by a 12 minute cooling period) |
General specifications
| Autoranging Display: |
3-3/4 digit LCD, 3999 counts with 41-segment analog bar graph |
| Display Update Rate |
2/sec, nominal |
| Power Battery |
9 V NEDA 1604, JIS 006P, IEC 6F22 |
| Battery Life |
200 hrs typical (alkaline) frequent use of backlight will decrease battery life |
| Operating Temperature |
0 ºC to 45 ºC at < 70% R.H |
| Storage Temperature |
-20 ºC to 60 ºC, 0 to 80 % R.H. with battery removed from meter |
| Dimensions: |
7.75" x 3.55" x 2.4" (196 x 92 x 60mm) |
| Weight (without holster, includingbattery) |
1 lb (400 gr) |
| Voltage AC |
750 TRMS AC |
| Voltage DC |
1000 V |
| mV AC |
TRMS |
| Basic DC Accuracy |
0.50% |
| DC Current, fused |
10:00 AM |
| AC Current, fused |
10 A TRMS |
| Resistance |
40MΩ |
| Capacitance |
400μF |
| Frequency |
10 MHz |
| Temperature |
1832 ºF / 1000 ºC |
|