| DC Voltage |
Ranges | 400 mV, 4 V, 40 V, 400 V, 1000 V |
| Accuracy all ranges |
± (0.7 % rdg + 1 dgt) |
| Resolution |
100 μV |
| Input Impedance |
10 MΩ |
| AC Voltage (45 Hz to 500 Hz) |
Ranges |
400 mV, 4 V, 40 V, 400 V, 750 V |
| Accuracy 4 V Range, 200 Hz to 500 Hz |
± (2.0 % rdg + 4 dgts) |
| Accuracy All other ranges |
± (1.5 % rdg + 4 dgts) |
| Resolution |
100 μV |
| Input Impedance |
10 MΩ |
| DC Current |
Ranges | 400 μA, 4 mA, 40 mA, 300 mA, 10 A |
| Accuracy 400 μA to 300 mA ranges |
± (1.0 % rdg + 1 dgt) |
| Accuracy 10A range |
± (2.0 % rdg + 3 dgts) |
| Resolution |
0.1 μA |
| Voltage Burden 400 μA range |
1 mV/μA |
| Voltage Burden 4 mA range |
100 mV/1 mA |
| Voltage Burden 40 mA range |
12 mV/1 mA |
| Voltage Burden 300 mA range |
4 mV/1 mA |
| Voltage Burden 10 A range |
100 mV/1 A |
| AC Current (45 Hz to 500 Hz) |
Ranges |
400 μA, 4 mA, 40 mA, 300 mA, 10 A |
| Accuracy 400 μA to 300 mA ranges |
± (1.5 % rdg + 4 dgts) |
| Accuracy 10 A range |
± (2.5 % rdg + 4 dgts) |
| Resolution |
0.1 μA |
| Voltage Burden See DC Current |
| Resistance |
Ranges | 400 Ω, 40 kΩ, 4 MΩ |
| Accuracy 400 Ω and 40 kΩ ranges |
± (1.0 % rdg + 4 dgts) |
| Accuracy 4 MΩ range |
± (1.2 % rdg + 4 dgts) |
| Resolution |
100 mΩ |
| Open Circuit Voltage 400 Ω range |
3.0 V dc |
| Open Circuit Voltage All other ranges |
0.5 V dc typical |
| Capacitance |
Ranges |
4 μF, 40 μF, 400 μF, 4000 μF |
| Accuracy 4 μF range |
± (5.0 % rdg + 10 dgts) |
| Accuracy 40 μF, 400 μF ranges |
± (5.0 % rdg + 5 dgts) |
| Accuracy 4000 μF range |
± (5.0 % rdg + 15 dgts) |
| Resolution |
0.1 μF |
| Test Voltage |
< 3.0 V |
| Test Frequency |
10 Hz |
| Input Protection μA/mA input |
0.315 |
| A/1000 V fast blow ceramic fuse |
6.3 x 32 mm |
| Temperature |
Ranges |
-20 ºC to 1000 ºC, -4 ºF to 1832 ºF |
| Accuracy -20 ºC to 10 ºC |
± (2.0 % rdg + 4 ºC ) |
| Accuracy 10 ºC to 200 ºC |
± (1.0 % rdg + 3 ºC ) |
| Accuracy 200 ºC to 1000 ºC |
± (3.0 % rdg + 2 ºC ) |
| Accuracy -4 ºF to 50 ºF |
± (2.0 % rdg + 8 ºF) |
| Accuracy 50 ºF to 400 ºF |
± (1.0 % rdg + 6 ºF) |
| Accuracy 400 ºF to 1832 ºF |
± (3.0 % rdg + 4 ºF) |
| Resolution |
1 ºC, 1 ºF |
| Frequency (autoranging) |
Ranges | 4 kHz, 40 kHz, 400 kHz, 4 MHz, 40 MHz |
| Accuracy all ranges |
± (0.1 % rdg + 3 dgts) |
| Resolution |
1 Hz |
| Sensitivity 10 Hz to 4 MHz |
> 1.5 V ac rms |
| Sensivity 4 MHz to 40 MHz |
> 2 V ac rms, < 5 V ac rms |
| Min Pulse Width |
> 25 ns |
| Duty Cycle Limits |
> 30 % and < 70 % |
| Continuity |
Audible Indication | < 35 Ω |
| Response Time |
100 ms |
| Diode Test |
Test Current |
1.0 mA (approximate) |
| Accuracy |
± (1.5 % rdg + 3 dgts) |
| Resolution |
1 mV |
| Open Circuit Volts |
3.0 V dc typical |
| Peak Hold |
AC Volts Accuracy 40 V to 750 V |
± (3.0 % rdg + 60 dgts) |
| AC Current Accuracy |
± (3.0 % rdg + 60 dgts) |
| Response Time |
> 1 ms |
| Overload Protection |
AC/DC Voltage 400 mV range |
1000 V dc or 750 V ac rms 15 sec |
| AC/DC Voltage All other ranges |
1000 V dc or 750 V ac rms |
| AC/DC Current uA/mA input |
0.315 A /1000 V fast-blow ceramic (6.3 x 32 mm) |
| AC/DC Current 10A input |
10 A /1000 V fast-blow ceramic (10 x 38 mm)(10 A for 4 minutes maximum followed by a 12 minute cooling period) |
| Resistance |
1000 V dc or 750 V ac rms |
| Continuity |
1000 V dc or 750 V ac rms |
| Diode Test |
1000 V dc or 750 V ac rms |
| Capacitance |
0.315 A /1000 V fast-blow ceramic (6.3 x 32 mm) |
| Temperature |
1000 V dc or 750 V ac rms |
| Frequency |
1000 V dc or 750 V ac rms |