Wavetek Meterman 15XP Autoranging Ranging Multimeter

Click image to enlarge
Wavetek Meterman 15XP
|
|
Features:
- Autoranging display for faster measurements
- 2000-count 3-1/2 digit display
- VolTect Non-Contact Voltage Detector lets you safely detect dangerous AC voltages
- Magne-Grip Holster with magnetic hanging strap that frees both hands for work
- TTL logic test for digital circuits
- Integrated tilt stand for easy bench use
- Resistance and continuity for troubleshooting bad connections
- Diode test for component level troubleshooting
- Data Hold freezes display to “hold” measurement reading
- 750 V ac/1000 V dc – highest voltage rating in this class of meter
- MSRP $59.95 (US)
Warranty: One-year, no-hassle
|
Description
The Meterman XP series of multimeters combine features and accuracy in a small device. Each XP multimeter has built-in non-contact voltage (NCV) detection, Magne-Grip holster and CAT III safety ratings. Three models to choose from:
- 5XP – 2000-count manual ranging meter for residential and commercial electrical use, and general purpose troubleshooting.
- 15 XP – 2000-count autoranging with logic test for electronic and field service applications.
- 35XP – 4000-count autoranging with temperature and capacitance for industrial, HVAC and electronic applications.
Included accessories:
- One pair test leads TL245
- Fuse 2A/1000 V P/N FP200
- 9 V battery (installed)
- Operating instructions
- Holster and magnet strap
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| 15XP |
Compact Dmm With Ncv And Logic Test - Discontinued - suggested replacement: Amprobe 15XP-B |
| 5XP |
Compact Dmm With Non-Contact Voltage - Discontinued - suggested replacement: Amprobe 5XP-A |
| 35XP |
Compact Dmm With Temp, Freq, Capacitance - Discontinued - suggested replacement: Amprobe 35XP-A |
Specifications
| DC Volts |
Ranges |
200 mV, 2 V, 20 V, 200 V, 1000 V |
| Resolution |
100 V |
| Accuracy |
± (0.5 % rdg + 1 dgt) |
| Input impedance 400 mV: |
>100 MΩ |
| Input impedance 4 V: |
10 MΩ |
| Input Impedence 40 V ~ 1000 V: |
9.1 MΩ |
| Overload protection |
1000 VDC or 750 VAC rms |
| AC Volts (45 Hz - 500 Hz) |
Ranges |
200 mV, 2 V, 20 V, 200 V, 750 V |
| Resolution |
100 V |
| Accuracy 45 Hz ~ 100 Hz on 200 mV range |
± (1.5 % rdg + 5 dgts) |
| Accuracy on 2 V to 750 V ranges |
± (1.5 % rdg + 5 dgts) |
| Input impedance 400 mV: |
>100 MΩ |
| Input impedance 4 V: |
10 MΩ |
| Input impedance 40 V ~ 1000 V: |
9.1 MΩ |
| Overload protection |
1000 VDC or 750 VAC rms |
| DC Current |
Ranges |
200 A, 2000 A, 20 mA, 200 mA, 2 A |
| Resolution |
0.1 A |
| Accuracy on 200 A to 200 mA ranges |
± (1.0 % rdg + 2 dgt) |
| Accuracy on 2 A range |
± (2.0 % rdg + 3 dgts) |
| Input protection |
2 A/1000 V fast blow ceramic fuse 6.3 x 32 mm on A input |
| Burden voltage |
500 mV max. (2 V max. on 2 mA, 200 mA ranges) |
| AC Current (45 Hz - 500 Hz) |
Ranges |
200 A, 2000 A, 20 mA, 200 mA, 2 A |
| Resolution |
0.1 A |
| Accuracy on 200 A to 200 mA ranges |
± (1.5 % rdg + 5 dgts) |
| Accuracy on 2 A range |
± (2.5 % rdg + 5 dgts) |
| Input protection |
2 A/1000 V fast blow ceramic fuse 6.3 x 32 mm on A input |
| Burden voltage |
500 mV max. (2 V max. on 2 mA, 200 mA ranges) |
| Resistance |
Ranges |
200 Ω, 2 kΩ, 20 kΩ, 200 kΩ, 2 MΩ, 20 MΩ |
| Resolution |
100 mΩ |
| Accuracy on 200 Ω to 2 MΩ ranges |
± (1.0 % rdg + 4 dgts) |
| Accuracy on 20 MΩ range |
± (3.0 % rdg + 5 dgts) |
| Open circuit volts - |
0.45 V dc typical, (-1.2 Vdc on 200 Ω range) |
| Overload protection |
1000 VDC or 750 VAC rms |
| Continuity |
Audible indication |
Less than 25 Ω |
| Response time |
100 ms |
| Overload protection |
1000 VDC or 750 VAC rms |
| Diode Test |
Test current |
1.2 mA (approximate) |
| Accuracy |
±(1.5 % rdg + 3 dgts) |
| Resolution |
1 mV |
| Open circuit volts |
3.0 dc typical |
| Overload protection |
1000 VDC or 750 VAC rms |
| Logic Test |
Logic test |
TTL |
| Thresholds Logic 1 (Hi ) |
2.8 V ± 0.8 V |
| Thresholds Logic 0 (Lo) |
0.8 V ± 0.5 V |
| Test voltage |
TTL 5 VDC |
| Frequency range |
20 MHz |
| Pulse width |
25 ns min |
| Duty cycle limits |
> 30 % and < 70 % |
| Indication |
40 ms beep at Logic 0 ( Lo) |
| Overload protection |
1000 VDC or 750 VAC rms |
| Non-Contact Voltage Indicator |
Sense voltage |
70 V to 600 VAC (50 Hz ~ 60 Hz) beeper chirps and big bright red LED comes on, works on all ranges |
General specifications
| Display |
3-1/2 digit liquid crystal display (LCD) with a maximum reading of 1999 |
| Polarity |
Automatic, positive implied, negative polarity indication |
| Overrange |
(OL) or (-OL) is displayed |
| Zero |
Automatic |
| Low battery indication |
The low battery icon is displayed when the battery voltage drops below theoperating level |
| Auto power off |
Approx. 10 minutes |
| Measurement rate |
2 times per second, nominal |
| Operating environment |
0ºC to 50ºC at <70 % R.H. |
| Storage temperature |
-20ºC to 60ºC, 0 to 80 % R.H. with battery removed from meter |
| Accuracy |
Stated accuracy at 23ºC ± 5ºC, <75 % relative humidity |
| Temperature coefficient |
0.1 x (specified accuracy) perºC (0ºC to 18ºC, 28ºC to 50ºC) |
| Altitude |
6561.7 feet (2000 M) |
| Power |
Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
| Battery life |
200 hours typical with carbon-zinc |
| Dimensions |
155 mm (H) x 72 mm (W) x 32 mm (D) |
| Weight |
Approx. 210 g including battery |
| Safety |
Designed to meet IEC 1010-1, Rev-2 CAT I 1000 V, CAT II 600 V,CAT III 300 V, class 2 and pollution deg. 2 indoor use. Complies with CE,and CSA 22.2 No. 1010-1 requirements |
| Auxiliary Features |
Data hold Freeze the latest reading on the displayRange Execute manual range modeAuto power off After auto power off, press (RANGE), (HOLD) button to restart the meter,and the last reading of measurement will be maintained in the display. A jack Input warning detects wrong connection. |
|