Vitrek V5 Scanning Electrical Safety Analyzer

Click image to enlarge
Vitrek V5
|
|
Features:
- Built-in 8 Channel Scanner
- Tests AC, DC Hipot, IR & Ground Bond to UL, CSA, IEC & TUV Specs
- Up to 5KVAC 40mA
- Up to 6KVDC 10mA
- Multi-mode IR 50-1000V up to 10,000MΩ
- Ground Bond up to 42Amps
- Leakage current resolution down to 10ΩA
- Fully programmable RS232 optional GPIB interface
- Selectable arc detection
- Available Safety Fault Interrupt (SFI) circuit
- CE mark certified EN61010
- 10 position test sequence memory
- 3 year extended warranty
|
Description
|
Only Vitrek, world leaders in electrical safety test automation, could build a feature rich, full function 5-in-1 electrical safety tester with performance this high and a price this low. The new Vitrek V5 combines AC Hipot to 5KV, DC Hipot to 6KV, insulation resistance to 10 gig-ohms and high current ground bond measurement up to 42 Amps and a built-in 8 channel HV Scanner. And all this comes in one systems ready, low profile, rugged, rack mount package – complete with rear terminal outputs.
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| V5 |
Scanning Electrical Safety Analyzer |
| $4999.00 |  |
|
| Model |
Accessories |
List Price |
Sale Price |
| GP-V5 |
GPIB Interface Option |
| $495.00 |  |
|
| TL-115-5 |
Hipot / GB Outlet Test Adaptor |
$195.00 |
| $191.10 |  |
|
| TL-10-60 |
Test Leads with HV Probe |
$95.00 |
| $93.10 |  |
|
| TL-20-60 |
Alligator Test Lead Set |
$85.00 |
| $83.30 |  |
|
| TL-IEC5 |
IEC Socket Lead Set |
| $115.00 |  |
|
| K-2 |
High Current 4-wire, 2 Clip Kelvin Lead Set |
| $185.00 |  |
|
| K-4 |
High Current 4-wire, 4 Clip Kelvin Lead Set |
| $195.00 |  |
|
| SFI-2 |
Safety Fault Interupt Option |
| $100.00 |  |
|
| MHL-4U |
Mating HV Lead 4 Ft., Unterminated |
| $45.00 |  |
|
| MHL-4A |
Mating HV Lead with Alligator Clip |
| $50.00 |  |
|
Specifications
| AC Hipot |
| Voltage Range |
100 to 5000 VAC RMS |
| Voltage Setting Resolution |
5V/step |
| Voltage Regulation |
1% of reading + 5V |
| Voltage Accuracy |
1% of reading + 10V |
| Voltage Monitoring |
At Output Terminals |
| Output Current |
30mA to 40mA 180S max, 0 to 30mA continuous. Below 500V 10mA max |
| Min/Max Current Limits |
0.1 to 40mA |
| Current Accuracy |
1% of reading + 50mA |
| DC Hipot |
| Voltage Range |
100 to 6000 VDC |
| Voltage Setting Resolution |
5V/step |
| Voltage Regulation |
1% of reading + 5V |
| Voltage Accuracy |
1% of reading + 10V |
| Voltage Monitoring |
At Output Terminals |
| Max Output Current |
10mA continuous, below 500VDC 2mA continuous |
| Min/Max Current Limits |
0.01 to 10mA |
| Current Accuracy |
1% of reading + 50mA |
| Insulation Resistance |
| DC Output Voltage |
50, 100, 500 or 1000V |
| Resistance Range |
1 to 9999mW |
| Resistance Accuracy (% of reading) |
| 50, 100 VDC |
1-50MW 5% 51-200MW 10% 201-1999MW 20% |
| 500, 1000 VDC |
1-500MW 5% 501-2000MW 10% 2001-9999MW 20% |
| Multi-Mode IR |
Select 1 of 3 modes - test passes on good reading, test fails on bad reading, pass/fail determined at end of test time. |
| Ground Bond/Continuity |
| Test Current |
3A to 42 Amps RMS |
| Terminal Configuration |
4 wire Kelvin |
| Resistance Range |
0 to 600mW |
| Resistance Resolution |
100mW |
| Resistance Accuracy |
1% reading ± 3mW |
| Compliance Voltage |
8 volts at terminals |
| Current Resolution |
0.01A |
| Voltage Resolution |
0.01V |
| General |
| Test Database |
10 test sequences with up to 16 steps per test sequence |
| Front Panel Lockout |
Prevents database edit while in lockout mode |
| Arc Detect |
10 level trip select |
| Remote Interfaces |
RS232 - Fully interactive, PLC - Inputs; Start, Reset |
| Outputs |
Testing, Pass, Fail, GPIB - Option GP-V5 |
| Timer Accuracy |
0.25% ± 50mS |
| Power Source |
AC100v, 120V, 220V, 230V (±10% 50/60Hz), 350W max |
| Operating Environment |
Indoor use, altitude up to 6500 ft (2000m). Installation Category II. Pollution Degree 2. |
| Operating Temperature |
0°C to 40°C, 80% RH |
| Storage Temperature |
-10°C to 70°C, 70% RH |
| Dimension |
17 W x 17 D x 5.25 H, (432mm x 432mm x 133mm) |
| Weight |
39lbs (18kg) net, 45 lbs (20kg) ship |
| Accessories |
NIST Cal Cert, TL-20-60 & K-2 Test Leads, Instruction Manual and Power Cord. |
| Accuracy |
Stated specifications apply for 1 year at 23°C ± 5°C. |
| Calibration |
ANSI/NCSL Z540 Certificate of Calibration with Data traceable to NIST. |
| Compliance |
CE Mark Certified to EN61010 and EMC Directives EN50081-1 & EN50082-2. |
| Warranty |
3 Year Extended Warranty with registration and annual factory calibration, 1 year parts and labor standard. |
| QuickTest Software |
| Option QT-V5 |
Bundled Test Automation Software and PC Serial Interface Cable. Easy to load graphical test sequence development and operating environment. Provides time/date, operator, test parameters, test results and readings. Results may be viewed, printed out or exported to a database program. |
|