Unisource 9216A LCR Meter

Click image to enlarge
Unisource 9216A
|
|
Features:
- 0.05% Basic Accuracy
- 5 digit display
- Test frequencies from 100Hz to 100KHz
- 2V DC internal bias and external bias to 40V DC
- RS-232C and GPIB(option) Interface
|
Description
|
LCR Meter 9216A is a useful tool measuring a device characteristic with various functions. It has more than 13 orders of magnitude , basic accuracy of 0.05% and 5 test frequencies.
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| 9216A |
5-digit LED Display, 12Hz~100KHz Test Frequency, 0.05% Basic Accuracy, Auto/ R+Q/L+Q/C+D/C+R Measurement, 2V DC Internal Bias External Bias to 40V DC - Discontinued - suggested replacement: Protek 9216A |
| EDC-1630 |
Advanced Digital LCR Meter |
$2499.00 |
| $2294.25 |  |
|
|
The following table summarize typical measurement accuracies for the different ranges of the measurements.
|
| Accuracy/Value |
| better than 1% |
0.125Ω< R < 16MΩ 2.5uH < L < 25kH 1.25pF < C < 12.8mF |
| better than 5% |
21mΩ< R < 96MΩ 420uH < L < 150kH 21pF < C < 77mF |
| The following conditions apply : 1.0, 0.5 or 0.25V output voltage slow or medium measurement speed Q and D < 0.1 for R and C, Q > 10 for L 100Hz, 120Hz or 1KHz test frequency for R 10Hz test frequency for L max and C max
|
| Accessories |
| Standard Accessories |
Radial Fixture, Power cord, User manual |
| Optional Accessories |
GPIB/Handler interface IEEE-488 Interface Handler/Sorter Interface |
It provides both an IEEE-488 interface and a Handler interface.All instrument functions can be controlled or read over the interface.DB25 male connector provides output lines to indicate binning information and instrument status and an input trigger line.The trigger input is negative edge triggered TTL and is protected to +/1 15Volts. |
| Kelvin Clips |
Provides connection to devices that are not easily accommodated in the fixture. Polarity is indicated for biased measurements. |
| SMD Tweezers |
Provides connection to surface Mount Device Parts. Polarity is indicated for biased measurements. |
Specifications
| Display |
Measurement Modes : Auto, R+Q, L+Q, C+D, C+R Equivalent Circuit : Serial or Parallel Parameter Displayed : Value, Deviation, % Deviation or Bin Number. |
| Deviation and % deviation are calculated from a store relative value |
Averaging : 2-10 Measurement |
| Measurement Range |
R+Q : R, 0.0001~ 2000M Q, 0.00001 ~ 50 L+Q : L, 0.00001uH ~ 99999H Q, 0.00001 ~ 50 C+D : C, 0.0001pF ~ 99999uF D, 0.000001 ~ 10 C+R : C, 0.001pF ~ 99999uF R, 0.00001 ~ 99999K |
| Test Conditions |
Test Frequency : 100Hz, 120Hz, 1KHz, 10KHz, 100KHz Frequency Accuracy : ±100ppm Drive Voltage : Preset Levels : 0.10, 0.25 and 1.0 Vrms |
| Vernier |
0.1 to 1.0 Vrms with 50mV resolution Drive levels accuracy : ±2% |
| Measurement Rate |
Slow,
Medium, Fast : 2,10 or 20 Measurements per second at test frequencies
of 1KHz and above and about 0.6, 2.4 6 measurements per second at 100Hz and 120Hz.Ranging : Auto or Manual Triggering : Continuous, Manual or Remote over RS232, GPIB or Handler Interface Bias Voltage : Internal : 2.0VDC ± 2% |
| External |
0 to + 40 VDC (fused @0.25A) |
| Accuracy |
Conditions : At least 30 minute warm up, 23?±5? Basic Accuracy :0.05% |
|