Applications:

  • Adapts Existing TekProbe® Probe Types for Application with TekVPI™ Oscilloscopes
Features:
  • Enables Existing TekProbe® Products to Connect to the TekVPI™ Probe Interface of the new DPO7000 and DPO4000 Series Oscilloscopes
  • An Easy-to-use Plug-on Adapter to the Oscilloscope’s TekVPI Interface
  • Provides Necessary Power, Communication, and Offset Control as Needed by the Attached TekProbe Product
  • Provides Over-current and Thermal Overload Protection for the Attached TekProbe Product
  • Provides an LED Probe Status Indicator which Identifies that the Probe has Powered-up Successfully



  Description

TekVPI™ Interface Adapter

TPA-BNC Adapter enables existing TekProbe® interface products (active, differential, high voltage, current and optical probes) to be used with Tektronix' newest generation of DPO7000 and DPO4000 Series Oscilloscopes which feature the new TekVPI™ probe interface architecture. Existing TekProbe-BNC probe types simply plug into the TPA-BNC adapter which is then plugged directly into any TekVPI probe channel of the DPO7000 and DPO4000 Series oscilloscopes. The TPA-BNC adapter recognizes and supplies the necessary power and serial communication and offset control as used by the connected TekProbe product accessory.

Note: Tektronix probe types using a BNC connection, or a BNC connection with a single analog encoding pin for attenuation factor detection connect directly to the oscilloscope’s TekVPI probe interface and do not require a TPA-BNC adapter.

TekProbe® Interface

TekProbe is a probe interface architecture introduced in 1986, and used on many earlier models of Tektronix oscilloscopes including the TDS300, TDS400, TDS500, TDS600, TDS700, TDS3000/B, TDS5000/B and TDS7000 Series. In addition to coupling the signal from the probe to the oscilloscope, the TekProbe interface provides power and offset control to active probes. It also allows the oscilloscope to sense the probe’s attenuation scale factor and/or probe type.




  Models, Options, & Accessories


Model Description List Price Sale Price
TPA-BNC PROBE ADAPTER FROM TEKPROBE-BNC PROBE TO TekVPI SCOPE INTERFACE-STATEMENT OF COMPLIANCE INCLUDED WITH THIS PRODUCT $412.00
$407.88 
Model Accessories List Price Sale Price
ADA400A AMPLIFIER, DIFF; MICROVOLT, DIFFERENTIAL, - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD $1510.00
$1494.90 
P5205 PROBE,DIF ACT; TEK PROBE PWR, 1KV, 100 MHZ - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD $1150.00
$1138.50 
P5210 PROBE,DIF ACT; TEK PROBE PWR, 2KV COMMON, 5.6 KV DIFFERENTIAL, 50 MHZ - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD $2300.00
$2277.00 
P6243 ACTIVE PROBE; 1 GHZ - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD $846.00
$837.54 
P6245 PROBE,FET ACT; >1.5GHZ,10X,<1PF,TDS SERIES - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD $1880.00
$1861.20 
P6246 PROBE,DIFF,ACT; 400MHZBW,+/-0.85/8.5V,1PF,TPI - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD $2760.00
$2732.40 
P6247 PROBE,DIFF,ACT; 1GHZ BW,+/- 0.85/8.5V,1PF,TPI - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD $3900.00
$3861.00 
P6248 PROBE; 1.7GHZ DIFFERENTIAL - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD $4800.00
$4752.00 
P6330 PROBE; DIFFERENTIAL; 3.5 GHZ BW, BNC, +/-1.75 V DIFFERENTIA.L DYNAMIC RANGE, +5V -4V COMMON MODE RANGE, 2.3 MV RMS NOISE AT INPUT, 5X ATTENTUATION-CERTIFICATE OF TRACEABLE CALIBRATION STANDARD $5900.00
$5841.00 
TCPA300 AMPLIFIER; AC/DC CURRENT PROBE; DC-100MHZ; CERTIFICATE OF TRACEABLE CALIBRATION STANDARD $1930.00
$1910.70 
TCPA400 AMPLIFIER; AC/DC CURRENT PROBE; DC-50MHZ; CERTIFICATE OF TRACEABLE CALIBRATION STANDARD $1930.00
$1910.70 
TPA-BNC-R1PW REPAIR SERVICE COVERAGE 1 YEAR POST WARRANTY $60.00
$59.40 
TPA-BNC-R2PW REPAIR SERVICE COVERAGE 2 YEARS POST WARRANTY $120.00
$118.80 
TPA-BNC-R3DW REPAIR SERVICE COVERAGE 3 YEARS (INCLUDES PRODUCT WARRANTY PERIOD) 3 YEAR PERIOD STARTS AT TIME OF CUSTOMER INSTRUMENT PURCHASE - Discontinued - no replacement
TPA-BNC-R5DW REPAIR SERVICE COVERAGE 5 YEARS (INCLUDES PRODUCT WARRANTY PERIOD) 5 YEAR PERIOD STARTS AT TIME OF CUSTOMER INSTRUMENT PURCHASE - Discontinued - no replacement


  Specifications


Bandwidth - DC to >3 GHz.
VSWR - <1.23:1 up to 3 GHz.
RF Insertion Loss - <0.25 dB.
Delay Time - 245 ps.
Maximum Input Signal Voltage - 42 Vpk-pk, 30 VRMS, 60 VDC

Physical Characteristics

Dimensions mm in.
Height 43 1.694
Width 30.5 1.200
Length 62.2 2.449
Weight kg lbs.
Shipping 0.45 1

Power Requirements

  • TPA-BNC is powered directly from DPO7000 and DPO4000 Series Oscilloscopes, using TekVPI probe interface.

Environmental


Temperature
Operating - 0° C to +50° C.
Non-Operating - –40° C to +75° C.
Humidity
Operating - 5% to 95% Relative Humidity (RH) up to +30° C; 5% to 85% RH above +30° C up to +50° C, non-condensing.
Non-Operating - 5% to 95% Relative Humidity (RH) up to +30° C; 5% to 85% RH above +30° C up to +75° C, non-condensing.
Altitude
Operating - Up to 3,000 m (10,000 feet).
Non-Operating - Up to 15,240 m (50,000 feet).

Regulatory


Compliance Labeling - WEEE (European Union).

Standard Warranty


One year parts and labor.

Recommended Oscilloscopes

  • DPO7000 and DPO4000 Series Oscilloscopes with TekVPI probe interface.



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET