Tektronix Logic Analyzers
TLA7N4 Logic Analyzer Module
Characteristics
General
Number
of Channels (all channels are acquired including clocks) - TLA7N4: 136
channels (4 are clock and 4 are qualifier channels).
Channel Grouping -
No limit to number of groups or number of channels per group (all channels
can be reused in multiple groups).
Module "Merging" - Three
modules can be "merged" to make up to a 408-Channel module. Merged modules
exhibit the same depth as the lesser of the three individual modules. Word/range/setup-and-hold/glitch/transition
recognizers span all three modules. Only one set of clock connections is required.
Time
Stamp - 50-Bit at 500 ps resolution (6.5 day range).
Clocking/Acquisition
Modes - Internal, internal 2X, external. 2 GHz MagniVu high-speed timing
is available simultaneous with all modes.
Number of Mainframe Slots
Required per TLA Series Module - 2.
Input Characteristics (with
P6417, P6418, P6419, or P6434 probes)
Capacitive Loading -
<0.7
pF data and clock (P6419).
1.4 pF typical data; 2 pF typical clock
(P6418).
2 pF typical data and clock (P6417 & P6434).
Threshold
Selection Range - From +5.0 V to -2.0 V in 50 mV increments.
Threshold
Selection Channel Granularity - Separate selection for clock (1) and data
(16) for each 17-Channel probe connector.
Threshold Accuracy (including
probe) - ±100 mV.
Input Voltage Range - Operating: 6.5 Vp-p centered
around the programmed threshold.
Non-destructive: ±15 V.
Minimum
Input Signal Swing - 250 mV or 25% of signal swing, whichever is greater
(P6417, P6418, & P6419).
300 mV or 25% of signal swing (P6434).
Input
Signal Minimum Slew Rate - 200 mV/ns typical.
State Acquisition
Characteristics (with P6417, P6418, P6419, or P6434 probes)
State
Clock Rate - 100 MHz standard, 200 MHz optional.
State Data
Rate (half/full channels) - 400/200 Mb/s, typical. Requires 200 MHz state
option.
State Memory Depth with Timestamps - 64 Kb, 256 Kb,
1 Mb, or 4 Mb per channel.
Setup-and-hold Time Selection Range
- From 8.5 ns before, to 7.0 ns after clock edge.
Setup-and-hold
Window - 2 ns typical.
Minimum Clock Pulse Width - 2 ns.
Active
Clock Edge Separation - 5 ns.
Demux Channel Selection - Channels
can be demultiplexed to other channels through user interface with 8-Channel
granularity.
Timing Acquisition Characteristics (with P6417, P6418,
P6419, or P6434 probes)
MagniVu™ Timing - 500 ps.
MagniVu
Timing Memory Depth - 2 Kb (2048) per channel.
Deep Timing
Resolution (half/full channels) - 2/4 ns to 50 ms.
Deep Timing
Resolution with Glitch Storage Enabled - 10 ns to 50 ms.
Deep
Timing Memory Depth (half/full channels with timestamps and with or without
transitional storage) - 128/64 Kb, 512/256 Kb, 2/1 Mb, 8/4 Mb per channel.
Deep
Timing Memory Depth with Glitch Storage Enabled - Half of default main
memory depth.
Channel-to-channel Skew - <1 ns typical.
Minimum
Recognizable Pulse Width (single channel) - 2 ns.
Minimum Recognizable
Glitch Width (single channel) - 2 ns.
Minimum Recognizable
Multi-channel Trigger Event - Sample period +2 ns.
Trigger Characteristics
Independent
Trigger States - 16.
Maximum Independent If/then Clauses per
State - 16.
Maximum Number of Events per If/then Clause - 8.
Maximum
Number of Actions per If/then Clause - 8.
Maximum Number of
Trigger Events - 18 (2 counter/timers plus any 16 other resources).
Number
of Word Recognizers - 16.
Number of Range Recognizers - 4.
Number
of Transition Recognizers - 1.
Number of Counter/Timers - 2.
Trigger
Event Types - Word, group, channel, transition, range, anything, counter
value, timer value, signal, glitch, setup-and-hold violation.
Trigger
Action Types - Trigger module, trigger all, store, don't store, start
store, stop store, increment counter, reset counter, start timer, stop timer,
reset timer, goto state, set/clear signal, do nothing.
Trigger
Sequence Rate - DC to 250 MHz (4 ns).
Counter/Timer Range - 51 Bits
each (>100 days at 4 ns).
Counter Rate - DC to 250 MHz (4 ns).
Timer
Clock Rate - 250 MHz (4 ns).
Counter/Timer Latency - None
(can be tested or reset immediately after starting).
Range Recognizers
- Double bounded (can be as wide as any group, must be grouped according
to specified order of significance).
Setup-and-hold Violation Recognizer
Setup Time Range - From 8 ns before to 7 ns after clock edge in 0.5 ns
increments.
Setup-and-hold Violation Recognizer Hold Time Range
- From 7 ns before to 8 ns after clock edge in 0.5 ns increments.
Trigger
Position - Any data sample.
MagniVu Trigger Position - MagniVu
data is centered around the module trigger.
Storage Control (data
qualification) - Global (conditional), by state (start/stop), by trigger
action, or transitional.
Storage Window Granularity - Single
sample or block-of-31 samples before and after.
Safety - CSA
C22.2 No. 1010.1, EN61010-1, IEC61010-1, UL 3111-1
Physical
Physical
Characteristics
|
Dimensions
|
mm
|
in.
|
|
Height
|
262
|
10.3
|
|
Width
|
61
|
2.4
|
|
Depth
|
381
|
15
|
|
Weight
|
kg
|
lb.
|
|
Net (w/o probes)
|
3.1
|
6.7
|
|
Shipping (typical)
|
6.3
|
13.7
|