Tektronix Logic Analyzers
TLA7Axx Logic Analyzer Modules
Characteristics
General
Number
of Channels (all channels are acquired including clocks) - TLA7AA1: 34
channels (2 are clock channels).
TLA7AA2, TLA7AB2: 68 channels (4 are clock
channels).
TLA7AA3: 102 channels (4 are clock and 2 are qualifier channels).
TLA7AA4,
TLA7AB4: 136 channels (4 are clock and 4 are qualifier channels).
Channel
Grouping: No limit to number of groups or number of channels per group (all
channels can be reused in multiple groups).
Module "Merging"
- Up to five 102 channel or 136 channel modules can be "merged" to make
up to a 680 channel module. Merged modules exhibit the same depth as the lesser
of the five individual modules.
Word/setup-and-hold/glitch/transition recognizers
span all five modules. Range recognizers limited to three module merge. Only
one set of clock connections is required.
Time Stamp - 51-Bits
at 125 ps resolution (3.25 days duration).
Clocking/Acquisition
Modes - Internal, internal 2X, internal 4X, external, external 2X, external
4X, source synchronous. 8 GHz MagniVu high-speed timing is available simultaneous
with all modes.
Number of Mainframe Slots Required per TLA Series
Module - 2.
Input Characteristics (with P68xx or P69xx probes)
Capacitive
Loading -
0.5 pF clock/data (P69xx)
<0.7 pF clock/data (P68xx)
(1.0 pF
for P6810 in group configuration).
Threshold Selection Range
- From -2.0 V to +4.5 V in 5 mV increments.
Threshold presets include
TTL (1.5 V), CMOS (1.65 V), ECL (-1.3 V), PECL (3.7 V), LVPECL (2.0 V), LVCMOS
1.5 V (0.75 V), LVCMOS 1.8 V (0.9 V), LVCMOS 2.5 V (1.25 V), LVCMOS 3.3 V
(1.65 V), LVDS (0 V) and user-defined.
Threshold Selection
Channel Granularity - Separate selection for each of the clock/qualifier
channels and one per group of 16 data channels for each 34 channel probe.
Threshold
Accuracy (including probe) - ±(35 mV + 1%).
Input Voltage Range
- Operating: -2.5 V to 5.0 V.
Nondestructive: ±15 V.
Minimum
Input Signal Swing - 300 mV (single-ended).
V¯MAX - VMIN >
150 mV (differential).
Input Signal Minimum Slew Rate - 200 mV/ns
typical.
State
Acquisition Characteristics (with P68xx or P69xx probes)
State
Acquisition
|
Full Channel
|
Half Channel
|
Quarter Channel
|
|
120 MHz Standard
|
235 MHz/235 Mb/s or 240 Mb/s (DDR)
|
235 MHz/470 Mb/s
|
|
235 MHz Optional
|
450 MHz/450 Mb/s or 470 Mb/s (DDR)
|
450 MHz/900 Mb/s
|
|
450 MHz Optional
|
800 MHz/800 Mb/s or 900 Mb/s (DDR)
|
625 MHz/1.25 Gb/s
|
State Memory Depth with Timestamps - (quarter/half/full
channels) 512/256/128 Kb, 2 Mb/1 Mb/512 Kb, 8/4/2 Mb, 32/16/8 Mb, 128/64/32 Mb,
256/128/64 Mb per channel.
Setup and Hold Time Selection Range
- From 16 ns before, to 8 ns after clock edge in 125 ps increments. Range
may be shifted towards the setup region by 0 ns [+8, -8] ns, 4 ns [+12, -4] ns,
or 8 ns [+16, 0] ns.
Setup-and-hold Window - All Channels:
625 ps typical.
Single Channel: 500 ps typical.
Minimum
Clock Pulse Width - 500 ps (P6960, P6964, P6980, P6982, P6860, P6864,
P6880), 700 ps (P6810).
Active Clock Edge Separation - 400 ps.
Demux
Channel Selection - Channels can be demultiplexed to other channels through
user interface with 8 channel granularity.
Source Synchronous Clocking
- Up to four "Fast Latches" per module (20 max per 5-way merge) to strobe
source-synchronous buses into TLA7Axx Modules.
Four sets of any predefined
"Fast Latches" may be combined with qualification data and data pipelining
to store four independent source-synchronous data buses.
Two "Fast
Latches" may be combined to address DDR applications.
Timing
Acquisition Characteristics (with P68xx or P69xx probes)
MagniVu™
Timing - 125 ps max, adjustments to 250 ps, 500 ps, 1 ns, and 2 ns.
MagniVu
Timing Memory Depth - 16 Kb per channel, with adjustable trigger position.
Deep
Timing Resolution (quarter/half/full channels) - 500 ps/1 ns/2 ns to 50 ms.
Deep
Timing Resolution with Glitch Storage Enabled - 4 ns to 50 ms.
Deep
Timing Memory Depth (quarter/half/full channels with timestamps and with or
without transitional storage) - 512/256/128 Kb, 2 Mb/1 Mb/512 Kb, 8/4/2 Mb,
32/16/8 Mb,128/64/32 Mb, 256/128/64 Mb per channel.
Deep Timing
Memory Depth with Glitch Storage Enabled - Half of default main memory
depth.
Channel-to-channel Skew - 300 ps typical.
Minimum
Recognizable Pulse/Glitch Width (single channel) - 500 ps (P6960, P6964,
P6980, P6982, P6860, P6864, P6880), 750 ps (P6810).
Minimum Detectable
Setup/Hold Violation - 250 ps.
Minimum Recognizable Multi-channel
Trigger Event - Sample period + channel-to-channel skew.
Analog
Acquisition Characteristics (with P68xx or P69xx probes)
Bandwidth
- 2 GHz typical.
Attenuation - 10x, ±1%.
Offset
and Gain (Accuracy) - ±50 mV, +/-2% of Signal Amplitude.
Channels
Demultiplexed - 4.
Run/Stop Requirements - None, analog
outputs are always active.
iView™ Analog Outputs - Compatible
with any internal TLA7Dx/Ex DSO module or supported TDS external oscilloscope.
iView
Analog Output BNC Cable - Low loss, 10x, 36-in.
Trigger Characteristics
Independent
Trigger States - 16.
Maximum Independent If/then Clauses per
State - 16.
Maximum Number of Events per If/then Clause - 8.
Maximum
Number of Actions per If/then Clause - 8.
Maximum Number of
Trigger Events - 18 (2 counter/timers plus any 16 other resources).
Number
of Word Recognizers - 16.
Number of Transition Recognizers
- 16.
Number of Range Recognizers - 4.
Number
of Counter/Timers - 2.
Trigger Event Types - Word, group,
channel, transition, range, anything, counter value, timer value, signal,
glitch, setup-and-hold violation, snapshot.
Trigger Action Types
- Trigger module, trigger all modules, trigger main, trigger MagniVu,
store, don't store, start store, stop store, increment counter, decrement
counter, reset counter, start timer, stop timer, reset timer, snapshot current
sample, goto state, set/clear signal, do nothing.
Maximum Triggerable
Data Rate - 1250 Mb/s (4X clocking mode).
Trigger Sequence
Rate - DC to 500 MHz (2 ns).
Counter/Timer Range - 51 Bits
each (>50 days at 2 ns).
Counter Rate - DC to 500 MHz (2 ns).
Timer
Clock Rate - 500 MHz (2 ns).
Counter/Timer Latency - 2 ns.
Range
Recognizers - Double bounded (can be as wide as any group (408 channel
max), must be grouped according to specified order of significance).
Setup-and-hold
Violation Recognizer Setup Time Range - From 8 ns before to 7 ns after
clock edge in 125 ps increments. This range may be shifted towards the positive
region by 0 ns, 4 ns, or 8 ns.
Setup-and-hold Violation Recognizer
Hold Time Range - From 7 ns before to 8 ns after clock edge in 125 ps
increments. This range may be shifted towards the positive region by 0 ns
[+8, –8] ns, 4 ns [+12, –4] ns, or 8 ns [+16, 0] ns.
Trigger Position
- Any data sample.
MagniVu Trigger Position - MagniVu position
can be set from 0% to 60% centered around the MagniVu trigger.
Storage
Control (data qualification) - Global (conditional), by state (start/stop),
block, by trigger action, or transitional. Also force main prefill selection
available.
Physical Characteristics
|
Dimensions
|
mm
|
in.
|
|
Height
|
262
|
10.3
|
|
Width
|
61
|
2.4
|
|
Depth
|
381
|
15
|
|
Weight
|
kg
|
lb.
|
|
Net
|
3.1
|
6.7
|
|
Shipping
|
6.3
|
13.7
|