TEquipment.NET Logo
Call Us 1-877-571-7901
Tektronix TDS210 60 MHz 2 Channels Digital Real-Time Oscilloscope
 
HACKER SAFE certified sites prevent over 99.9% of hacker crime.  
 
 
 



Tektronix TDS210 60 MHz 2 Channels Digital Real-Time Oscilloscope




Click image to enlarge

Applications:

  • Service and Repair
  • Education and Training
  • Manufacturing Test and Quality Control
  • Design and Debug
Features:
  • 60 MHz or 100 MHz with 1 GS/s Sample Rate on all Channels
  • 2 and 4 Channel Models
  • Dual Timebase
  • Automatic Measurements
  • Multi-language User Interface
  • Autoset
  • Waveform and Setup Memories
  • Extended Capabilities Are Provided with Optional Modules, Software and Probing



  Description

Tektronix' Most Popular DSO

The TDS200 Oscilloscopes have quickly become the benchmark for low-cost oscilloscopes. Offering an unbeatable combination of performance, reliability and versatility, the TDS200 Series offers breakthrough digital and real-time advantages at low-cost analog oscilloscope prices. And with the recent introduction of the TDS224, Tektronix brought the digital performance of the TDS200 to customers that need four full-featured channels.

Affordable Digital Performance

No other digital oscilloscope offers as much bandwidth and sample rate for the price. By sampling at 10 and 16 times their bandwidths on all channels, the TDS200 Series oscilloscopes provide accurate real-time acquisition up to their full bandwidth.

Digital storage technology supports features not available on most low-cost oscilloscopes, including automatic measurements, peak detect, storage of two reference waveforms and five instrument setups and autoset. Peak detect and high sample rates minimize aliasing while capturing waveform details that remain unseen on many low-cost oscilloscopes.

Versatility and Flexibility

The TDS200's reliable, backlit liquid crystal display permits the instrument to be only 4.75 in (12 cm) from front to back, while its light weight (3.25 lbs, 1.5 kg) and rugged construction allow for portability. The portable form factor provides increased versatility, allowing the instrument to be easily moved or safely stored away when not in use.

Two productivity enhancing modules are available with capabilities not possible on many low-cost oscilloscopes. The Communication Extension Module allows RS-232 and GPIB programmability, plus the printing of screen shots via a Centronics-type parallel port. The Measurement Extension Module combines the features of the Communications Module plus Fast Fourier Transform (FFT) analysis and four additional measurements. Other optional accessories, such as WaveStarTM software and the AD007 GPIB-LAN adapter, add additional functionality to the TDS200.

Easy to Use

The user interface is similar to that of an analog oscilloscope, but with improvements that reduce learning time and increase efficiency.Knobs and buttons are grouped by function and provide direct access to controls, and each vertical channel has its own dedicated scale and position knobs. Readouts or menus are displayed on-screen at all times, allowing users to more quickly and accurately determine instrument settings. The display responds quickly to control adjustments and has a fast update rate.

All models have a multi-language user interface. Menus and help text are provided in a user-selectable language: English, Spanish, French, German, Italian, Portuguese, Korean, Japanese, Traditional Chinese or Simplified Chinese.

The Personal Oscilloscope

The TDS200 Series oscilloscopes are designed for people who demand the ultimate in oscilloscope value. If an inexpensive yet high performance oscilloscope is needed for the bench, production line or training lab, a TDS200 Series Oscilloscope is the best choice.




  Models, Options, & Accessories


Model Description List Price Sale Price
TDS210 TDS210 - Discontinued - replaced by Tektronix TDS2002C
TDS220 TDS220 - Discontinued - replaced by Tektronix TDS2012C
TDS224 TDS224 - Discontinued - replaced by Tektronix TDS2014C



  Specifications

Bandwidth TDS210: 60 MHz. TDS220: 100 MHz. TDS224: 100 MHz.
Sample Rate
1 GS/s on each channel.
1 GS/s on each channel.
1 GS/s on each channel.
Channels
2 identical channels plus external trigger
2 identical channels plus external trigger
4 identical channels
Sensitivity (with calibrated fine adjustment)
2 mV to 5 V/div (bandwidth limited to 20 MHz at 2 mV/div and 5 mV/div, in all modes, and 20 MHz at 10 mV/div in Peak Detect mode).
2 mV to 5 V/div (bandwidth limited to 20 MHz at 2 mV/div and 5 mV/div, in all modes, and 20 MHz at 10 mV/div in Peak Detect mode).
2 mV to 5 V/div (bandwidth limited to 20 MHz at 2 mV/div and 5 mV/div, in all modes, and 20 MHz at 10 mV/div in Peak Detect mode).
Vertical Zoom
Vertically expand or compress a live or stopped waveform.
Vertically expand or compress a live or stopped waveform.
Vertically expand or compress a live or stopped waveform.
Calibrated Position Range
  Volts/Div Settings Offset Range  
2 mV to 200 mV/div ±2 V
>200 mV to 5 V/div ±50 V
DC Gain Accuracy ±3%. (±4% at 2 mV/div and 5 mV/div). ±3%. (±4% at 2 mV/div and 5 mV/div). ±3%. (±4% at 2 mV/div and 5 mV/div).
Vertical Resolution 8-Bits (256 levels over 10.24 vertical divisions). 8-Bits (256 levels over 10.24 vertical divisions). 8-Bits (256 levels over 10.24 vertical divisions).
Automatic Measurements Period, Frequency, Cycle RMS, Mean, Peak to Peak. Period, Frequency, Cycle RMS, Mean, Peak to Peak. Period, Frequency, Cycle RMS, Mean, Peak to Peak.
Acquisition Modes
Sample, Average, Peak Detect - High frequency and random glitch capture; captures glitches as narrow as 10 ns using acquisition hardware at all time/div settings between 5 µs/div and 5 s/div.
Time Base System (Main and Window)
Horizontal Zoom Horizontally expand or compress a live or stopped waveform. Horizontally expand or compress a live or stopped waveform. Horizontally expand or compress a live or stopped waveform.
Time/Division Range 5 ns to 5 s/div. 5 ns to 5 s/div. 5 ns to 5 s/div.
Record Length 2500 sample points per channel. 2500 sample points per channel. 2500 sample points per channel.
Horizontal Accuracy ±0.01%. ±0.01%. ±0.01%.
Nonvolatile Storage
Waveform Display Two 2500 point reference waveforms. Two 2500 point reference waveforms. Two 2500 point reference waveforms.
Waveform Storage Two 2500 point reference waveforms Two 2500 point reference waveforms Four 2500 point reference waveforms
Setups 5 front panel setups. 5 front panel setups. 5 front panel setups.
Triggering System (Main Only)
Trigger Type Edge (Rising or Falling), Video, Set to 50%. Edge (Rising or Falling), Video, Set to 50%. Edge (Rising or Falling), Video, Set to 50%.
Video Trigger Type Triggers on Fields or Lines from composite video; triggers on broadcast standard NTSC, PAL or SECAM video. Triggers on Fields or Lines from composite video; triggers on broadcast standard NTSC, PAL or SECAM video. Triggers on Fields or Lines from composite video; triggers on broadcast standard NTSC, PAL or SECAM video.
Trigger Modes Auto, Normal, Single Sweep. Auto, Normal, Single Sweep. Auto, Normal, Single Sweep.
Trigger Source CH1, CH2, Ext, Ext/5 and AC Line. CH1, CH2, Ext, Ext/5 and AC Line. CH1, CH2, CH3, CH4 and AC Line.
Trigger View Displays trigger signal while trigger view button depressed. Displays trigger signal while trigger view button depressed. Displays trigger signal while trigger view button depressed.
Cursors
Types Voltage, Time. Voltage, Time. Voltage, Time.
Measurements [DELTA]T, 1/[DELTA]T, [DELTA]V. [DELTA]T, 1/[DELTA]T, [DELTA]V. [DELTA]T, 1/[DELTA]T, [DELTA]V.
Waveform Processing
Arithmetic Operators Add, Subtract. Add, Subtract. Add, Subtract.
Sources CH1±CH2 CH1±CH2 CH1±CH2, CH3±CH4
Autoset Single button automatic setup on selected input signal for vertical, horizontal and trigger systems. Single button automatic setup on selected input signal for vertical, horizontal and trigger systems. Single button automatic setup on selected input signal for vertical, horizontal and trigger systems.
Display System Robust, backlit LCD with adjustable multilevel contrast. Robust, backlit LCD with adjustable multilevel contrast. Robust, backlit LCD with adjustable multilevel contrast.
Interpolation Sin(x)/x. Sin(x)/x. Sin(x)/x.
Display Modes Vectors, dots. Vectors, dots. Vectors, dots.
Persistence Off, 1 sec, 2 sec, 5 sec, Infinite. Off, 1 sec, 2 sec, 5 sec, Infinite. Off, 1 sec, 2 sec, 5 sec, Infinite.
Format YT and XY. YT and XY. YT and XY.
Hardcopy Capability (Requires Modules)
Printer/File Formats Thinkjet, Deskjet, Laserjet, Epson (9- or 24-Pin), BMP, PCX, IMG, EPS, DPU 411, DPU 412. Thinkjet, Deskjet, Laserjet, Epson (9- or 24-Pin), BMP, PCX, IMG, EPS, DPU 411, DPU 412. Thinkjet, Deskjet, Laserjet, Epson (9- or 24-Pin), BMP, PCX, IMG, EPS, DPU 411, DPU 412.
Hardcopy Layout Landscape or Portrait. Landscape or Portrait. Landscape or Portrait.
TDS2CM Communications Extension Module
Centronics Type Parallel Port Parallel Port Parallel Port
RS-232 Programmability Full talk/listen modes. Control of all modes, settings and measurements. Baud Rate up to 19,200. 9-Pin, DTE. Full talk/listen modes. Control of all modes, settings and measurements. Baud Rate up to 19,200. 9-Pin, DTE. Full talk/listen modes. Control of all modes, settings and measurements. Baud Rate up to 19,200. 9-Pin, DTE.
GPIB Programmability Full talk/listen modes. Control of all modes, settings and measurements (IEEE Std 488-1987). Full talk/listen modes. Control of all modes, settings and measurements (IEEE Std 488-1987). Full talk/listen modes. Control of all modes, settings and measurements (IEEE Std 488-1987).
Includes WaveStarTM Software for Oscilloscopes 30 day product demo.
TDS2MM Measurement Extension Module
FFT Windows: Hanning, Flat Top, Rectangular.
Sample points: 2048.
Windows: Hanning, Flat Top, Rectangular.
Sample points: 2048.
Windows: Hanning, Flat Top, Rectangular.
Sample points: 2048.
Automatic Measurements Rise/Fall Time, Positive/Negative Pulse Width Rise/Fall Time, Positive/Negative Pulse Width Rise/Fall Time, Positive/Negative Pulse Width
Interface Centronics, RS-232, GPIB. Centronics, RS-232, GPIB. Centronics, RS-232, GPIB.
Environmental and Safety
Temperature Operating: 0°C to +50°C.
Nonoperating: -20°C to +60°C.
Operating: 0°C to +50°C.
Nonoperating: -20°C to +60°C.
Operating: 0°C to +50°C.
Nonoperating: -20°C to +60°C.
Humidity Up to 90% RH at or below +40°C;
Up to 60% RH from 41°C to 50°C (Operating and Nonoperating).
Up to 90% RH at or below +40°C;
Up to 60% RH from 41°C to 50°C (Operating and Nonoperating).
Up to 90% RH at or below +40°C;
Up to 60% RH from 41°C to 50°C (Operating and Nonoperating).
Altitude Up to 3000 m (Operating). Up to 3000 m (Operating). Up to 3000 m (Operating).
EMC Meets Directive 89/336/EEC. Meets Directive 89/336/EEC. Meets Directive 89/336/EEC.
Safety UL3111-1, CSA1010.1, IEC61010-1, EN61010-1. UL3111-1, CSA1010.1, IEC61010-1, EN61010-1. UL3111-1, CSA1010.1, IEC61010-1, EN61010-1.




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers | FAQ's | Privacy
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 



Current Promotions