company logo Tektronix TCP312 AC/DC Current Measurement Systems
     Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.  
 
 
 



Tektronix TCP312 AC/DC Current Measurement Systems




Click image to enlarge



Development and Analysis For:

  • Power Supplies
  • Semiconductor Devices
  • Power Inverters/Converters
  • Electronic Ballasts
  • Industrial/Consumer Electronics
  • Mobile Communications
  • Motor Drives
  • Transportation Systems
Features:
  • AC / DC Measurement Capabilities
  • DC – 100 MHz, Current Probe Amplifier (TCPA300) Uses:
    • DC – 100 MHz, 30 A DC (TCP312)
    • DC – 50 MHz, 50 A DC (TCP305)
    • DC – 15 MHz, 150 A DC (TCP303)
  • DC – 50 MHz, Current Probe Amplifier (TCPA400) Uses:
    • DC – 2 MHz, 750*1 A DC (TCP404XL) (500 A DC Continuous)
  • Direct Scaling and Units*2 – Oscilloscope On-Screen Readout Reduces Measurement Errors by Eliminating Hand Calculations
  • AC/DC Input Coupling
  • Low Insertion Impedance Reduces Device Under Test Loading
  • Small Mechanical Package – Less Desktop Space, Easier Storage and Handling
  • Split-Core Construction Allows Easy Circuit Connection
  • Status Indicators Provide Notification of Potential Error Conditions
  • Lower DC Drift and Noise
  • Certified for U.S., Canada, and Europe
*1 Derated with Duty Cycle
*2 Requires a TDS TEKPROBE Oscilloscope or a TekConnect Oscilloscope with TCA-BNC



  Description

TCP312

Probe; AC/DC Current, DC to 100 MHz; 30 A DC (Requires TCPA300 Amplifier)

All TCP300/TCP400 Current Probes Include:

AC/DC Current Probe; Instruction Sheet; Probe Cover; Certificate of Traceable Calibration

Increased performance and simplicity

The TCP300 and TCP400 series AC/DC Current Measurement family is a highly advanced current measurement system for today's current measurement needs. The split-core probes incorporate both transformer and Hall effect technology to provide broad bandwidth measurement capabilities from DC up to 100 MHz at current levels as low as 1 milliamp to thousands of amps (when used with CT4 current transformer). When connected to Tektronix TDS Oscilloscopes with TEKPROBE Level II or TekConnect (w/TCA-BNC) interfaces, current measurements and calculations are simple and easy.

Additional measurement power is available with add on software such as the TDSPWR2 power measurements package. With all this measurement power, current measurements have never been easier.

Meets today's AC/DC current measurement applications

The TCPA300 amplifier, when used with TCP312, TCP305, or TCP303 probes, provide a wide range of current measurement capability and spans the gap between low level milliamp measurements to very high current levels. These three probes provide current measurement capabilities of 30 A, 50 A, and 150 A DC continuous. For even higher current levels, the TCPA400 amplifier with the TCP404XL current probe measures 500 A DC continuous and 750 A DC continuous, derated with duty cycle.

Higher frequency performance is available with the TCP312 w/TCPA300 providing =100 MHz bandwidth and a maximum current of 30 A DC.

Measurement errors and manual calculations are now a thing of the past

With this new series of current measurement tools, automatic control and on-screen scaling and units is provided for users of Tektronix TDS3000, TDS500, TDS600, TDS700, TDS5000, TDS6000, and TDS7000B series oscilloscope systems. Status LEDs quickly show you TCP300/400 series operating status or potential error conditions that may have caused measurement errors in the past.

The TCP300/TCP400 Current Measurement Systems seamlessly integrate with your TDS series oscilloscope and the TDSPWR2 software package to easily make those time consuming power measurements and calculations for you.

Even non-TEKPROBE systems can use the TCPA 300/400 series to make proper current measurements by simply multiplying the measured output voltage on the oscilloscope by the TCPA 300/400 series range setting.




  Models, Options, & Accessories


Model Description List Price Sale Price
TCP312 PROBE,AC/DC CURRENT; DC-100MHZ, 30A DC, CERTIFICATE OF TRACEABLE CALIBRATION STANDARD $1460.00
$1445.40 
Model Accessories List Price Sale Price
TCP312 C3 CALIBRATION SERVICE 3 YRS. PROVIDES TRACEABLE OR FUNCTIONAL VERIFICATION EVENTS WHICHEVER ARE APPLICABLE TO THE PRODUCT. CALS ARE AT TEKTRONIX RECOMMENDED INTERVAL DURING THE COVERAGE PERIOD. CAL COVERAGE INCLUDES THE MANUFACTURERS CAL + 2 $240.00
$237.60 
TCP312 C5 CALIBRATION SERVICE 5 YRS. PROVIDES TRACEABLE OR FUNCTIONAL VERIFICATION EVENTS WHICHEVER ARE APPLICABLE TO THE PRODUCT. CALS ARE AT TEKTRONIX RECOMMENDED INTERVAL DURING THE COVERAGE PERIOD. CAL COVERAGE INCLUDES THE MANUFACTURERS CAL + 4 $450.00
$445.50 
TCP312 D1 TEST DATA; CAL DATA REPORT $26.00
$25.74 
TCP312 D3 TEST DATA; ON DELIVERY AND W/FURTHER CALS; MUST ORDER W/C3 $50.00
$49.50 
TCP312 D5 CALIBRATION DATA REPORT 5 YEARS (WITH OPTION C5) $100.00
$99.00 
TCP312 R3 REPAIR WARRANTY; EXTENDED TO COVER 3 YEARS $210.00
$207.90 
TCP312 R5 REPAIR SERVICE 5 YEARS $370.00
$366.30 
196312001 Lead, Electrical; Discrete, Probe Ground; 23 AWG, 6.0 L, Alligator Clip - Discontinued - no replacement
TCP312-CA1 PROVIDES A SINGLE CALIBRATION EVENT OR COVERAGE FOR THE DESIGNATED CALIBRATION INTERVAL, WHICHEVER COMES FIRST. $125.00
$123.75 
TCP312-R1PW REPAIR SERVICE COVERAGE 1 YEAR POST WARRANTY $115.00
$113.85 
TCP312-R2PW REPAIR SERVICE COVERAGE 2 YEARS POST WARRANTY $225.00
$222.75 
TCP312-R3DW REPAIR SERVICE COVERAGE 3 YEARS (INCLUDES PRODUCT WARRANTY PERIOD) 3 YEAR PERIOD STARTS AT TIME OF CUSTOMER INSTRUMENT PURCHASE - Discontinued - no replacement
TCP312-R5DW REPAIR SERVICE COVERAGE 5 YEARS (INCLUDES PRODUCT WARRANTY PERIOD) 5 YEAR PERIOD STARTS AT TIME OF CUSTOMER INSTRUMENT PURCHASE - Discontinued - no replacement


  Specifications

    TCP312 w/TCPA300 TCP305 w/TCPA300 TCP303 w/TCPA300 TCP404XL w/TCPA400
Bandwidth (-3 dB) DC – 100 MHz DC – 50 MHz DC – 15 MHz DC – 2 MHz *1
Risetime =3.5 ns =7 ns =23 ns =175 ns
Maximum Current Ratings:
High Current Sensitivity Range DC (continuous) RMS (sinusoidal) Peak Pulse 10 A/V Range     30 A 21.2 A 50 A 10 A/V Range     50 A 35.4 A 50 A 50 A/V Range     150 A 150 A 500 A 1 A/mV Range     500 A (750 A *2) 500 A 750 A
Low Current Sensitivity Range DC (continuous) RMS (sinusoidal) Peak Pulse 1 A/V Range     5 A 3.5 A 50 A 5 A/V Range     25 A 17.7 A 50 A 5 A/V Range 25 A 17.7 A 500 A N/A
DC Accuracy (Operating temp 0 °C to 50 °C) ±3% of reading ±3% of reading ±3% of reading (10 °C to 50 °C) +3%/-6% of reading (0 °C to <10 °C) ±3% of reading
DC Accuracy, Typical (Operating temp 23 °C ±5 °C) ±1% of reading ±1% of reading ±1% of reading ±1% of reading
Nominal
Maximum Bare Wire Voltage For Use With Insulated Wires Only 600 VRMS CAT I & II 300 VRMS CAT III
Lowest Measurable Current (at ±3% accuracy at DC) 1 mA 5 mA 5 mA 1 A
Scope Set To 1 mV/div and 20 MHz BW Limited Scope Set To 1 mV/div and 20 MHz BW Limited
Insertion Impedance (See Curves Below) 0.08 O at 1 MHz 0.15 O at 10 MHz 0.27 O at 50 MHz 0.7 O at 100 MHz 0.035 O at 1 MHz 0.12 O at 10 MHz 0.4 O at 50 MHz 0.01 O at 1 MHz 0.025 O at 5 MHz 0.1 O at 15 MHz 0.1 mO at 10 kHz 0.6 mO at 100 kHz 8 mO at 1 MHz 16 mO at 2 MHz
Typical
Maximum Amp-Second Product (Based on Amplifier Range setting) 50 A*µS – 1 A/V 500 A*µS – 10 A/V 500 A*µS – 5 A/V NA – 10 A/V 3,000 A*µS – 5 A/V 15,000 A*µS – 50 A/V NA – 1 A/mV
AC Coupling Low Frequency Bandwidth <7 Hz (Low Pass - 3 dB point)
Displayed RMS Noise (at 20 MHz Bandwidth Limit) =250 µA RMS =1.25 mA RMS =2.5 mA RMS =250 mA RMS
Signal Delay (Delay to Output BNC) 17 ns 19 ns 53 ns 103 ns
Inputs (probe amplifier) 1
Probe Open Indicator YES
Overload Indicator YES
Termination Indicator YES
Non-Compatible Probe Indicator YES
Safety Certifications
U.S. NRTL Listing UL3111-1 (Amplifier) UL3111-2-032 ; UL3111-1 (Probe and Amplifier)
Canadian Certification CAN/CSA C22.2 No.1010.1 (Amplifier) CAN/CSA C22.2 No.1010.2.032 CAN/CSA C22.2 No.1010.1 (Probe and Amplifier)
European Union Compliance EN61010-1/A2 (Amplifier) EN61010-1/A2; EN61010-2-032 EN61010-1/A2 (Probe and Amplifier)
Other IEC61010-1/A2 (Amplifier) IEC61010-2-032 IEC61010-1/A2 (Probe and Amplifier)
Electromagnetic Compatibility Meets EC Council Directive 89/336/EEC, FCC Part 15, Subpart B Class A, AS/NZS 2064.1/2.
Power Requirements (TCPA300/TCPA400 Amplifiers) 90 V to 264 V; 47 to 440 Hz; 50 W Maximum CAT II (Auto Switch)
Power Requirements (Probes) Requires TCPA300 Amplifier Requires TCPA400 Amplifier
Probe Model TCP312 TCP305 TCP303 TCP404XL
Warranty 1 Year
Probe Mechanical Characteristics
Probe Cable Length 1.5 meters (60 inches) 2 meters (78.7 inches) 8 meters (315 inches)
Probe Jaw Size (Max Conductor Size) 3.8 mm (0.15 inches) 21 mm x 25 mm (0.83 x 1.0 inches)
Length: Width: Height: Weight: 20 cm (7.87 inches) 1.6 cm (0.625 inches) 3.2 cm (1.25 inches) 0.15 kg (0.33 lb.) 26.8 cm (10.55 inches) 4.1 cm (1.60 inches) 15.6 cm (6.13 inches) 0.66 kg (1.45 lb.) 26.8 cm (10.55 inches) 4.1 cm (1.60 inches) 15.6 cm (6.13 inches) 0.88 kg (1.90 lb.)
TCPA300 and TCPA400 Mechanical Characteristics
Length: Width: Height: Weight: 17.3 cm (6.8 in) 16.7 cm (6.6 in) 9.14 cm (3.6 in) 1.14 kg (2.5 lb.)
Environmental Characteristics
Temperature - Operating 0 °C to +50 °C (32 °F to 122 °F)
Temperature - Nonoperating -40 °C to +75 °C (-40 °F to 167 °F)
Humidity – Operating 5% to 95% R.H.to +30 °C (86 °F) 5% to 85% R.H.+30 °C to +50 °C (86 °F to 122 °F)
Humidity – Nonoperating 5% to 95% R.H.to +30 °C (86 °F) 5% to 85% R.H.+30 °C to +75 °C (86 °F to 167 °F)
Altitude – Operating 2000 m (6800 ft) maximum
Altitude – Nonoperating 12,192 m (40,000 ft) maximum




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 



Live chat by BoldChat
Need help? We have a staff
of more than 30 people to help you.
Let us show you why over 100,000
customers choose Tequipment.NET