Bandwidth
- DC to =120 MHz
Rise Time - =2.92 ns
Max RMS
Current - 30 A
Max Peak Pulse Current - 50 A
Minimum
Sensitivity -
1 mA (on oscilloscopes that support 1 mV/div setting)
AC
Coupling (on oscilloscopes that support AC/DC coupling)
Current
Ranges - 5 A and 30 A
Max Bare Wire Voltage - Use insulated
wire only
Typical Characteristics
DC Accuracy - ±1%
typical
±3% warranted
Max Amp-Second Product - 500 A*µS
(in 30 A Range)
Insertion Impedance -
1 mO @ 10 kHz
3.5 mO
@100 kHz
0.08 O @ 1 MHz
0.15 O @ 10 MHz
0.7 O @ 100 MHz
0.85
O @ 120 MHz
Signal Delay - 14.5 ns
Environmental
Temperature
- Operating: 0 ºC to +50 ºC
Non-Operating: –40 ºC to +75 ºC
Humidity
- Operating: 5% to 95% Relative Humidity (RH) at up to +30 ºC; 5%
to 85% RH above 30 ºC up to +50 ºC, non-condensing
Non-Operating: 5%
to 95% Relative Humidity (RH) at up to +30 ºC; 5% to 85% RH above 30 ºC up
to +75 ºC, non-condensing
Altitude - Operating: Up
to 3,000 m (10,000 feet)
Non-Operating: Up to 12,192 m (40,000 feet)
Regulatory
Compliance
Labeling - CE (European Union)
WEEE (European Union)
Physical
Characteristics
|
Probe Head Size
|
cm
|
in.
|
|
Height
|
3.2
|
1.25
|
|
Width
|
1.6
|
0.625
|
|
Length
|
20
|
7.77
|
|
Other Dimensions
|
|
Cable Length
|
200
|
79
|
|
Max Conductor Diameter
|
0.38
|
0.15
|
|
Weight
|
kg
|
lbs.
|
|
Shipping
|
1.55
|
3.44
|
|
Power Requirements
|
|
TCP0030 is powered directly by the DPO7000 and DPO4000
Series Oscilloscopes using TekVPI™ interface
|
Recommended Oscilloscopes
DPO7000 and DPO4000 Series
Oscilloscopes with TekVPI™ probe interface.
Standard Warranty
One year parts and labor.