Features:
  • Easy to use
  • Large, easy-to-read display
  • Data log up to ten sets; timed logging 400 sets
  • PC interface
  • IR printer port
  • Protective rubber boot included

Functions:
  • Combustion Efficiency Analyzer
    • Measure O2 and CO
    • Calculate CO2, efficiency, excess air and ratio.
    • Will work with high efficiency furnaces, hot water heaters, and other combustible gas appliances.
  • Combustible Gas Detector
    • Set at 100 ppm sensitivity for natural gas
  • CO Analyzer
    • Measure 0-10,000 ppm CO
  • Differential Thermometer
    • Dual input K-Type thermocouple temperature tester
  • Differential Digital Manometer
    • Dual input differential manometer with 3 selectable units of measure: kPa, mBar, inH2O.



Model Description List Price Sale Price
712 Combustion Analyzer w/pump, soft case, stack probe, O2, CO, Temp,pressure $849.95
$764.96 
712A740 712 Combustion Analyzer and A740 $949.95
$854.96 
Model Accessories List Price Sale Price
A767 IRDA adapter for 712 and 714 $74.95
$67.46 
A772 PC Software $69.95
$62.96 
A740 IR printer $199.95
$179.96 


   Specifications

Temperature Measurement
Range: -40° to 1472°F, or -40° to 800°C
Resolution: 1°F or C
Accuracy (K-type): ±0.3%, ±2°F or ±1°C
Draft/Pressure Measurement
Selectable Ranges: mBar, kPa, and inH2O
Ranges: -150 mBar to +150 mBar, -15 kPa to +15 kPa, -60 inH2O to +60 inH2O
Resolution: 0.01mBar
Accuracy: ±0/5% fsd
Gross/Net Efficiency
Range: 0 to 100%
Resolution: 0.1%
Oxygen (O2) Measurement
Range: 0 to 25%
Resolution:0.1%
Accuracy:±0.3%
Carbon Monoxide (CO) Measurement
Range: 0 to 10,000 ppm
Resolution: 1 ppm
Accuracy: ±5 ppm or 5%, whichever is greater
Carbon Dioxide (CO2)
Range: 0 to 25%
Resolution: 0.1%
Accuracy: Calculated
CO/CO2 Ratio
Range: 0 to 0.999
Resolution: 0.001
Accuracy: Calculated
General
Operating Temperature Range: 14° to 122°F (-10° to 50°C)
Battery: Rechargeable Ni-MH, >6 Hour Life
Charger Input Voltage: 115V or 230V : 50/60 Hz AC
Fuels: Natural Gas, LPG, Light Oil, Heavy Oil
Display: Backlit LCD
Data Storage: 10 sets of readings
Data Logging: 400 sets of readings on ‘Timed Interval Logging’
Time & Date: 24 Hour Real Time Clock
Dimensions: 200mm x 90mm x 60mm
Weight: 500g
Exhaust: Safety Spigot
Conforms To: BS7927 (and the draft BS7967)



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET