Simpson 501 Insulation Tester

Click image to enlarge
Simpson 501
|
|
Features:
- Five Test Voltages: 50, 100, 250, 500, and 1000 VDC
- Voltage Measurement to 1000 V AC/DC
- Test Probe Signal Lamp Illuminates Work Area and Indicates Pass/Fail of Insulation Resistance
- Battery Powered with Battery Test and Battery Charge Indicator
- Rugged Tester Design fo Industrial Applications with Leatherette Carrying Case
|
Description
|
Simpson’s Model 501 is the newest addition to its insulation tester family. The Model 501 can be used for general purpose insulation tests that require voltages from 50 V to 1000 V only. Additionally, this instrument is equipped with AC and DC measuring ranges up to 1000 V. This is especially advantageous for testing devices for the absence of voltage and the discharge of capacitive devices under test. The Model 501 features a quick testing signal lamp within the test probe that serves to illuminate the work area. The signal lamp can also be used for quick Pass/Fail evaluations of insulation resistances. Minimum values for insulation resistances are present if the lamp lights up. Each tester comes equipped with built-in test probes, one alligator clip, a leatherette carrying case and batteries.
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| 501 |
INSULATION TESTER, Item# 12501 |
$829.26 |
| $787.80 |  |
|
| 260-6XLM |
VOM, LOW POWER OHM, Item# 12206 |
$282.69 |
| $268.55 |  |
|
| Model |
Accessories |
List Price |
Sale Price |
| 46223 |
Please call or email us for pricing and availability. |
Specifications
| Reference Conditions |
| Ambient Temperature |
73°F (23°C) ± 4°F (2°C) |
| Relative Humidity |
45 to 55% |
| Measurement Magnitude Frequency |
45-65 Hz |
| Line Voltage Waveform |
Sine, deviation between effective and rectified value < .5% |
| Battery Voltage |
9V ±.5V |
| Operating Position |
Horizontal |
| Electromagnetic Compatibility EMC |
| Interference Emission |
EN 50081-1: 1992 |
| Interference Immunity |
EN 50082-1: 1992 |
| Electrical Safety |
| Protection Class |
II |
| Test Voltage |
5.55Kv |
| Overvoltage Classification |
II |
| Polution Degree |
2 |
| Protection |
Housing IP52 |
| Ambient Conditions |
| Operating Temp. Range |
32°F (0°C) to 104°F (40°C) |
| Storage Temp. Range |
-4°F (-20°C) to 140°F (60°C) |
| Relative Humidity |
Max. 45-55%, condensation must be avoided |
| Mechanical Design |
| Dimensions |
W 6.50in (165mm) x D 4.33in (110mm) x H 4.92in (125mm) |
| Weight |
3.5 lbs. (1.6kg) (with batteries) |
| Power Supply |
| Standard or Storage Battery |
6 ea. 1.5V D size batteries |
| Working Range |
7V to 10V |
| Battery Service Life |
Number of possible measurements with 1 set of D size batteries (with lamp in test prod switched on): at least 3,000 measurements of an insulation resistance of 1MΩ (Un=1000 V, 5 sec. Measurement duration, switched off for 25 sec. etc.) |
|