Rohde & Schwarz
FSH3-03 Spectrum Analyzer
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   



Rohde & Schwarz
FSH3-03 Spectrum Analyzer



Rohde & Schwarz FSH3-03
Click image to enlarge

 Rohde & Schwarz FSH3-03

Features:
  • Frequency range 100 kHz to 3 GHz
  • Internal preamplifier with frequency range from 100 kHz to 3 GHz
  • Displayed average noise level typ. -135 dBm (RBW 100 Hz)
  • High level accuracy: 0.5 dB typ
  • Resolution bandwidths 100 Hz to 1 MHz, 1 and 3 steps
  • Wide range of detectors: sample, max/min peak, auto peak, RMS
Applications:
  • General lab use
  • Cable installation and maintenance
  • Verify production line equipment
  • General field use for communications installation and maintenance
  • Field wireless equipment installation and maintenance



  Description

The Rohde & Schwarz FSH Series is the ideal spectrum analyzer for rapid, high-precision, cost-effective signal investigations. It provides a large number of measurement functions to handle anything from the installation or maintenance of a mobile radio base station, to on-site fault location in RF cables, to development and service.

Included Accessories:
  • External AC power supply
  • Battery pack (integral)
  • RS-232-C optical cable
  • Headphones
  • CD-ROM with Control Software (R&S FSH View and documentation)
  • Quick Start Manual.



  Applications and Options

TDMA Power Measurements
When TDMA methods are employed, e.g. GSM, several users share a frequency channel. Each user is assigned a single timeslot. The FSH's TDMA POWER function performs time-domain power measurements in these timeslots. All the settings required for the GSM and EDGE standards are predefined on the FSH to make these measurements easier for the user. The FSH can use external triggering or video triggering to start power measurements.

Channel-Power Measurements
The channel-power measurement function is for determining the power in a transmission channel specified by the user. After a few preliminary settings have been made, a single keystroke starts the FSH's spectrum measurement inside the channel, using a resolution bandwidth that is small relative to the channel bandwidth. The FSH then integrates the measured values indicated by the trace to obtain and display the total power. All the settings required for the digital mobile radio standards 3GPP WCDMA, cdmaOne, CDMA2000 1x are predefined ready for use. The FSH also takes the characteristics of the selected display mode (lin or log), the selected detector and the resolution bandwidth into account so that the result accuracy is comparable to that obtained with a thermal power meter.

Power Measurements
The Power Sensors FSH-Z1 and FSH-Z18 expand the FSH to a high-precision RF power meter up to 8 GHz and 18 GHz respectively. As with thermal sensors, the true RMS value of the measured signal is obtained over the entire measurement range of -67 dBm to +23 dBm irrespective of the signal waveform. In particular with modulated signals, additional measurement errors can thus be prevented, and handling becomes easy.

Measurements on Cables (distance-to-fault)
For rapid and accurate determination of the distance to any faults in an RF cable. Distance-to-fault measurements using the VSWR Bridge FSH-Z2 give an immediate overview of the state of the device under test (return loss and distance). The marker-zoom function allows detailed analysis of faults with a resolution of up to 1024 pixels.

Requires FSH313/323/626 (with built-in tracking generator), option FSH-B1 (distance-to-fault measurement) and FSH-Z2 (VSWR bridge and power divider).

Scalar Network Analysis
The FSH313/323/626 (with built-in tracking generator) can be used to determine the transmission characteristics (i.e. attenuation or gain) of two ports such as cables, filters, amplifiers, etc, rapidly and with a minimum of effort. A simple calibration procedure compensates for the attenuation introduced by measurement cables or any attenuators used for amplifier measurements. When the VSWR Bridge FSH-Z2 is attached, the matching (return loss or VSWR) at the input or output of two ports can be determined as well as their transfer function. The bridge is screwed directly onto the RF input and tracking generator output, and no extra or cumbersome cabling is required.

FSH View Software (included)
  • For Windows 98/ME/NT/2000/XP
  • Rapid and simple transfer of measurement data
  • Data export in ASCII or MS Excel formats
  • Printout of relevant data via Windows (screenshot of the FSH display for documentation)
  • Graphics data stored in standard formats (.bmp, .pcx, .png, .wmf)
  • Permanent and continuous transfer of sweeps to the PC; facilities for subsequent analysis (markers, zoom, etc)
  • Unlimited memory capacity for traces and other measurement information; comparison of new and old measurements
  • Generation of cable data with a built-in cable editor for distance-to-fault measurements
  • PC connectivity via interference-free, RS-232C optical interface



  Models, Options, & Accessories


Model Description List Price Sale Price
FSH3-03 Handheld spectrum analyzer 100 kHz - 3 GHz, RBW 100 Hz - 1 MHz LCD color display, Preamplifier ( SKU#1145.5850.03 )
$7460.00 
FSH3-13 Handheld spectrum analyzer 100 kHz - 3 GHz, RBW 1 kHz - 1 MHz LCD color display, tracking gen. ( SKU#1145.5850.13 )
$9590.00 
Model Accessories List Price Sale Price
FSH-B1 Option: Distance To Fault measurement including 1 m cable (needs FSH-Z2 or FSH-Z3) ( SKU#1145.5750.02 )
$1220.00 
FSH-Z1 Average power sensor for FSH 10 MHz - 8 GHz, 200 pW - 200 mW ( SKU#1155.4505.02 )
$2740.00 
FSH-Z2 VSWR bridge and power divider 10 MHz - 3 GHz, 50 Ohm, incl. open, short, load for calibration ( SKU#1145.5767.02 )
$2720.00 
FSH-Z20 Spare N-cable to option DTF FSH-B1, 1 m, male/female N-connector ( SKU#1145.5867.02 )
$380.00 
FSH-Z21 12 V car adapter ( SKU#1300.7579.02 )
$170.00 
FSH-Z22 Serial/parallel converter for printers with parallel interface to FSH ( SKU#1145.5880.02 )
$300.00 
FSH-Z25 Soft carrying bag for FSH ( SKU#1145.5896.02 )
$230.00 
FSH-Z30 Spare open/short standard for FSH-Z2, for calibration of VSWR measurement ( SKU#1145.5773.02 )
$410.00 
FSH-Z31 Spare 50 Ohm load standard for FSH-Z2, for calibration of VSWR and DTF measurement ( SKU#1145.5780.02 )
$410.00 
FSH-Z33 Spare power supply for FSH including mains plug for EU, GB and US ( SKU#1145.5809.02 )
$210.00 
FSH-Z34 Optical RS232 interface cable 1.5 m to FSH (spare) ( SKU#1145.5815.02 )
$240.00 
FSH-Z35 CD-ROM including FSH view software and manual for FSH (spare) ( SKU#1145.5821.02 )
$140.00 
FSH-Z36 Spare headphone to FSH ( SKU#1145.5838.02 )
$50.00 
RAZ Matching pad 50/75 Ohm, 0 - 2700 MHz, matching at one end, N-connectors ( SKU#0358.5714.02 )
$800.00 



  Specifications

Frequency
Frequency range 100 kHz to 3 GHz
Reference frequency Aging: 1 ppm/year
Temperature drift:0 °C to 30 °C, 30 °C to 50 °C, 2 ppm in addition 2 ppm/10 °C
Frequency counter Resolution:1 Hz
Counter accuracy: S/N > 25 dB, ± (frequency × reference frequency errror)
Frequency span 0 Hz, 10 kHz to 3 GHz
Spectral purity SSB phase noise: f = 500 MHz, 20 °C to 30 °C
30 kHz from carrier: <85 dBc (1 Hz)
100 kHz from carrier: <100 dBc (1 Hz)
1 MHz from carrier: <120 dBc (1 Hz)
Sweep time span = 0 Hz: 1 ms to 100 s
span > 0 Hz: 20 ms to 1000 s, min. 20 ms/600 MHz
Bandwidths Resolution bandwidths (-3 dB): 1145.5850.13, 1, 3, 10, 30, 100, 200, 300 kHz, 1 MHz, 1145.5850.03/.23, 1145.5850.06/.26: in addition 100 Hz, 300 Hz
Tolerance: ≤300 kHz, ±5 %, nominal, 1 MHz, ±10 %, nominal
Resolution bandwidths (-6 dB): with option ¸FSH-K3 installed, in addition 200 Hz, 9 kHz, 120 kHz, 1 MHz
Video bandwidths: 10 Hz to 1 MHz in 1, 3 steps
Amplitude
Display range average noise level displayed to +20 dBm
Maximum permissible DC voltage at RF input 50 V/80 V
Maximum power 20 dBm, 30 dBm (1 W) for max. 3 minutes
Intermodulation-free dynamic range third-order IM products, 2 × -20 dBm, reference level = -10 dBm, typ. 66 dB (typ. +13 dBm third-order intercept, IP3)
Displayed average noise level resolution bandwidth 1 kHz, video bandwidth 10 Hz, reference level ≤-30 dBm
10 MHz to 3 GHz: <-105 dBm, typ. -114 dBm
With preamplifier only models 1145.5850.03, 1145.5850.23, 1145.5850.06, and 1145.5850.26
10 MHz to 2.5 GHz: <-120 dBm, typ. -125 dBm
2.5 GHz to 3 GHz: <-115 dBm, typ. -120 dBm
Inherent spurious reference level ≤-20 dBm, f > 30 MHz, RBW ≤ 100 kHz: <-80 dBm
Input related spurious mixer level -40 dBm, carrier offset >1 MHz
Up to 3 GHz: <-70 dBc (nominal)
2nd harmonic mixer level -40 dBm
typ. <-60 dBc
Level display Reference level: -80 dBm to +20 dBm in steps of 1 dB
Display range: 100 dB, 50 dB, 20 dB, 10 dB, linear
Display units
Logarithmic: dBm, dBμV, dBmV with transducer also dBμV/m and dBμA/m
Linear: μV, mV, V, nW, μW, mW, W with transducer also V/m, mV/m and μV/m
Traces: 1 trace and 1 memory trace
Detectors:auto peak, maximum peak, minimum peak, sample, RMS
with option ¸FSH-K3 installed: in addition average and quasi-peak
Level measurement error:frequency >1 MHz, at reference level down to -50 dB, 20 °C to 30 °C: <1.5 dB, typ. 0.5 dB
Markers Number of markers or delta markers: max. 6
Marker functions: peak, next peak, minimum, center = marker frequency, reference level = marker level, all markers to peak
Marker displays: normal (level), noise marker, frequency counter (count)
Trigger free-running, video, external
Audio demodulation AM (video voltage without AGC) and FM
Inputs
RF input N female
Input impedance 50Ω
VSWR 10 MHz to 3 GHz: typ. 1.5
Trigger/external reference input BNC female, selectable
Trigger voltage TTL
Reference frequency 10 MHz
Required level from 50Ω:10 dBm
Outputs
AF output 3.5 mm mini jack
Output impedance
Open-circuit voltage
100Ω
adjustable up to 1.5 V
Tracking generator only models 145.5850.13, 1145.5850.23 and 1145.5850.26
Frequency range 5 MHz to 3 GHz
Output level model 1145.5850.13:-20 dBm (nominal)
model 1145.5850.23:0 dBm/-20 dBm, selectable
Output impedance 50 Ω, nominal
Interfaces
RS-232-C optical interface Baud rate:1200, 2400, 9600, 19200, 38400, 57600, 115200 baud
Power sensor:7-contact female connector (type Binder 712)



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET