Features:
  • 9 kHz to 3 GHz Frequency Range
  • Low Phase Noise and High Dynamic Range
  • 200 Hz to 1 MHz Resolution Bandwidth, Selectable in 16 Steps
  • Integrated High-Accuracy Frequency Counter with 1 Hz Resolution
  • Maximum Input Level of +33 dBm
  • USB-Interface
Applications:
  • Measurement of RF Spectrum (Level and Frequency)
  • Measurement of Radiated Interference (EMC)
  • Mobile Radio and Wireless Communications Design and Manufacturing Test (GSM, WCDMA, DECT, W-LAN, etc.)
  • TDMA Power Measurements
  • Education and Research
  • Government and Military
  • Service and Maintenance



  Description

The FS300 from Rohde & Schwarz is a highly accurate spectrum analyzer with a frequency range of 9 kHz to 3 GHz. Due to its modern, digital frequency processing technology it offers high measurement quality, high dynamic range and low noise floor at a favorable price. The instrument is designed for general purpose RF analysis, and suitable for a multitude of applications in laboratory, service and production.

The FS300 is part of the Smart Instruments family, representing a new class of affordable high-quality measuring instruments. This series of instruments is notable for its highly compact and robust design.

Ergonomic User Interface
Operation is menu-guided so that even untrained users will quickly obtain correct measurement results. Clear structures simplify navigation within the menus. Users familiar with spectrum analyzers from Rohde & Schwarz will quickly find the menu items they know from other Rohde & Schwarz instruments. The bright TFT color display with 320*240 pixel resolution allows traces to be read even at odd angles or when the incidence of light is unfavorable.

PC Software
A software package, FS300-K1, is available for powerful remote control of the instrument via USB interface. The software allows configuration, operation and display of measurement results on a PC. Measurement traces can be stored, compared with previous measurements, and exported in txt-format for further analysis.

Included Accessories:
  • Operating Manual
  • Power Cord
  • Certificate of Traceable Calibration



  Models, Options, & Accessories


Model Description List Price Sale Price
FS300 Spectrum analyzer 9 kHz - 3 GHz -115 - +33 dBm, RBW 200Hz - 1 MHz TFT color display
$7430.00 
Model Accessories List Price Sale Price
ZZA-300 19" rack adapter, 2 x 1/2, 3 HU for AM300/FS300/SM300/UP300/UP350
$320.00 



  Specifications

Frequency
Frequency range 9 kHz to 3 GHz
Reference frequency Aging: 2 x 10-4 / year
Temperature drift: 1 x 10-4, 5° C to 30° C
Frequency counter Resolution: 1 Hz, 10 Hz, 100 Hz, 1 kHz
Frequency span: 1 kHz to 3 GHz, 0 Hz
Spectral purity SSB phase noise: <-90 dBc (1 Hz), 10 kHz carrier offset, 9 kHz ≤ f ≤ 3 GHz
Residual FM: <100 Hz, typ. 60 Hz, 1 kHz resolution bandwidth, 1 kHz video bandwidth, 9 kHz ≤ f ≤ 3 GHz
Sweep time Span ≥ 1 kHz: 100 ms to 1000 s
Span = 0 Hz: 100 μs to 20 s
Bandwidths Resolution bandwidths (-3 dB):200 Hz to 1 MHz in 1, 2, 3, 5 sequences
Tolerance: 5% digital filter
Video bandwidths: 10 Hz to 1 MHz in 1, 2, 3, 5 sequences
Amplitude
Level measurement range >137 dB
Max. input level 50 MHz to 3 GHz:+33 dBm
10 MHz to 50 MHz:+26 dBm
9 kHz to 10 MHz:+20 dBm
Intermodulation-free range 1 MHz to 100 MHz:≤-60 dBc, two-tone signal with 2 x -30 dBm
100 MHz to 3 GHz:≤-70 dBc, 0 dB input attenuation
Harmonics ≤-60 dBc, -40 dBm, 0 dB input attenuation
Inherent spurious responses ≤-85 dBm terminated input, 0 dB input attenuation
Other spurious ≤-60 dBc, 10 MHz to 3 GHz, -30 dBm level at first mixer
Displayed average noise level ≤-110 dBm, typ. -120 dBm, f > 9 kHz, 300 Hz resolution bandwidth, 10 Hz video bandwidth, 0 dB input attenuation
1 dB compression point of first mixer -10 dBm, 100 kHz to 3 GHz, 0 dB input attenuation
Setting range of reference level -110 dBm to +36 dBm
RF input attenuation range 0 dB to 70 dB in 2 dB steps, manual selection or automatic coupling to reference level
Display range 80 dB, 40 dB, 16 dB, 8 dB, linear
Display units Logarithmic: dBm, dBμV, dBmV
Linear: V, W
Traces 1 active trace and 1 stored trace
Level measurement uncertainty ≤1.5 dB
Markers Marker: 1 marker and 1 delta marker
Marker functions: peak, next peak, marker to center, marker to reference
Marker display: normal, delta, noise marker, frequency counter
Trigger free run, video, external, line
Inputs
RF input Connector: N female
Input impedance: 50Ω
VSWR: <1.5m 10 MHz to 3 GHz, input attenuation ≥20 dB
Max. input level +33 dBm with 30 dB input attenuation
Max. DC voltage 30 V
External trigger input Connector: BNC female
Trigger voltage: TTL voltages
Reference frequency input Connector: BNC female
Reference frequency: 10 MHz ± 50 Hz
Input voltage: 0.5 to 2 V at 50Ω
Output
Reference frequency output Connector: BNC female
Reference frequency: 10 MHz
Output voltage: >0.5 V at 50Ω
Interfaces
USB-Host Connector: A plug
Protocol: Version 1.1
Command set: device-specific, remote control via supplied, Windows driver (Windows XP, 2000)
USB device Connector: B plug
Protocol: Version 1.1
Power Supply
Input voltage range 100 V to 240 V (AC), 50 Hz to 60 Hz, autoranging
Power consumption <35 VA
General
Display Type: 5.4" active TFT colour display
Resolution: 320 x 240 pixels
Memory locations Traces: 5
Device setups: 10
Ambient conditions Permissible temperature range: +5° C to +45° C, meets DIN EN 60068-2-1/2
Storage temperature range: -20° C to +70° C
Rel. humidity: 95% at +40° C, meets DIN EN 60068-2-3 (non-condensing)
Mechanical resistance Sinusoidal vibration: 5 Hz to 150 Hz, max. 2 g at 55 Hz, meets DIN EN 60068-2-6, DIN EN, 55 Hz to 150 Hz: 0.5 g constant 61010-1 and MIL-T-28800D class 5
Random vibration: 10 Hz to 500 Hz: 1.9 g, meets DIN EN 60068-2-64
Shock: shock spectrum, meets DIN EN 60068-2-27 and MIL-STD-810
Electromagnetic compatibility meets EN 555011 class B and EN 61326 (EMC Directive 89/336/EEC)
EMI field strength 10 V/m
Safety class DIN EN 61010-1 / IEC61010-1 UL3111-1; CSA22.2 No:1010.1
Dimensions (W x H x D) 219 mm x 147 mm x 350 mm
Weight 7.4 kg




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 




Fluke Sponsored March Madness Bracket Challenge

Quote Request

We Take POs, How To Order

Free Shipping on Select Premier Lines










Live chat by BoldChat
Let our engineers and cs staff help!
Need a quote? Need to check stock?
Have a technical question? No problem.
We are here to help.