Rigol DS1204B 200 MHz Digital Oscilloscope 4 Channel

Click image to enlarge
Rigol DS1204B
|
|
Features
- 200 MHz Bandwidth
- 16 kpts(half channel), 8 kpts(each channel) Memory Depth
- 4 channels + external trigger Channels
- 2 GSa/s(half channel), 1 GSa/s(each channel) Real-time Sample Rate
- 50 GSa/s Equivalent Sample Rate
- Conform to LXI consortium instrument standard class C, which enable to create and reset testing system fast, economically and efficiently
- Abundant trigger types: Edge, Pulse Width, Video, Pattern and Alternative triggers
- Unique adjustable trigger sensitivity enables to meet different demands
- Enable to measure 22 types of wave parameters and track measurements via cursor automatically
- Unique waveform record and replay function
- Fine delayed scan function
- Built-in FFT function, hold practical digital filters
- Pass/Fail detection function
- Math operations available to multiple waves
- Powerful PC application software UltraScope
- Standard configure interface: USB Device, Dual USB Host, LAN, support U disk storage and PictBridge print standard
- Support for remote command control
|
Description
200 MHz Digital Oscilloscope with 4 channels plus USB storage, USB and LXI connectivity, and 2 GSa/sec sampling
The DS1000B Series Oscilloscopes offer 4 Channel measurement capability with adjustable trigger sensitivity for effective noise removal and false trigger elimination. The DS1000B series offers built-in USB host support , USB flash drive support and PictBridge printer support. LXI class C LAN ethernet connectivity is standard. DS1000B oscilloscopes provide users with backlit keys, intuitive user interface and builtin menu help
Product Overview
DS1000B series oscilloscopes are designed with four analog channels and 1 external trigger channel, which can capture multi-channel signal simultaneously and meet industrial needs.
The powerful trigger and analyzer abilities make it easy to capture and analyze waves. Clear LCD displays and math operations enable users to view and analyze signal faster and more clearly.
Applications
- Electronic Circuit Design and Test
- View Transient Signal
- Manufacturing Test and Quality Control
- Education & Scientific Research
- Industry Control
- Design & Analysis of Mechanical and
- Electrical Products
Easy to Use Design
- Built-in help menu enables information getting more convenient
- Multiple Language menus, support Chinese & English input
- Support U disk and local files storage
- Waveform intensity can be adjusted
- To display a signal automatically by AUTO
- Pop-up menu makes it easy to read and use
- Provide a key measure, a key store/print shortcut keys
 |
4 analog channels - Users can view multi-channel signal simultaneously via the 4 analog channels, which can be operated independently. Each channel button, correspondingchannel mark on screen and waveform will be separated by specific colors.
|
 |
PictBridge print standard-DS1000B series offer standard configure interface and support PictBridge print standard, there are two modes are available: “PictBridge” and “Normal”, you can select the mode and setup corresponding parameters to finish printing operation.
|
 |
LXI standard, class C - RIGOL DS1000B series digitaloscilloscopes conform to LXI consortium instrument standard class C, which enable to create and reset testing system fast, economically and efficiently, inaddition, the system integrationfunction will be achieve moreeasily.
|
 |
Automatically Measure 22 Wave Parameters - DS1000B series oscilloscopes provide 22 types of wave parameters for automatically measuring which contains 10 Voltage and 12 Time parameters. |
 |
FFT cursor measure -In cursor mode, users can easily measure by moving cursor. Besides, 3 types of cursor measurement areoptional: Manual, Track and Auto |
 |
Multiple Trigger - DS1000B contain abundant triggers: Edge, Pulse Width, Video, Pattern and Alternative triggers. Especially the pattern trigger achieves trigger operation according to the logic relationship among channels, which can capture special digital information. Unique function of adjustable trigger sensitivity is good for filtering possible noise from signal in order to avoid false triggers. |
 |
Waveform Recording - In virtue of waveform recording function from DS1000B series, not only the outputs from four channels could be recorded, but also the waves outputted by Pass/Fail test could be easily recorded. Totally, up to 1000 frames of waves are available to record. Besides, users can analyze waves according to recall or save transient waves so as to get more exact datum. |
 |
UltraScope Software - RIGOL provides powerful PC application software: UltraScope, which enables to: Capture and measure wave; Perform local or remote operation; Save waves as “.bmp” format; Save files as “.txt” or “.xls” format; Print waveforms. |
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| DS1204B |
200 MHz Digital Oscilloscope with 4 channels plus USB storage, USB and LXI connectivity, and 2 GSa/sec sampling |
| $1395.00 |  |
|
| DS1064B |
60 MHz Digital Oscilloscope with 4 channels plus USB storage, USB and LXI connectivity, and 2 GSa/sec sampling - Discontinued - replaced by Rigol DS1074B |
| DS1104B |
100 MHz Digital Oscilloscope with 4 channels plus USB storage, USB and LXI connectivity, and 2 GSa/sec sampling |
| $1195.00 |  |
|
| DS1074B |
70 MHz Digital Oscilloscope with 4 channels plus USB storage, USB and LXI connectivity, and 2 GSa/sec sampling |
| $945.00 |  |
|
| Model |
Accessories |
List Price |
Sale Price |
| DS1000LMCable |
DS 1000D module ribbon cable *for use only with logic module units* - Discontinued - no replacement |
| GPIBC |
DS USB-GPIB CONVERTER - Discontinued - replaced by Rigol USB-GPIB |
| DScase |
Scope case |
| $50.00 |  |
|
| BNC |
BNC CABLE 1M LENTH - Discontinued - replaced by Rigol BNCCABLE |
| DS1000LM |
LOGIC MODULE FOR DS1000 LH1116 |
| $375.00 |  |
|
Specifications
| Acquisition |
| Sample Modes |
Real-Time Sample |
Equivalent Sample |
| Sample Rate |
2 GSa/s (half channel[1]) 1 GSa/s (each channel) |
50 GSa/s[2] |
| Averages |
A waveform will be displayed one time while all the channels finish N times sample, N could be selectable from 2, 4, 8, 16, 32, 64, 128 and 256 |
| Inputs |
| Input Coupling |
DC, AC, GND |
| Input Impedance |
1MΩ± 2.0% The input capacity is 18pF± 3pF |
| Probe Attenuation Factors |
0.001X, 0.01X, 0.1X, 1X, 2X, 5X, 10X, 20X, 50X, 100X, 200X, 500X, 1000X |
| Maximum Input Voltage |
Maximum Input Voltage of the analog channel: sCAT I 300Vrms, 1000Vpk; transient overvoltage 1000Vpk sCAT II 100Vrms, 1000Vpk sRP2200 10:1, CAT II 300Vrms sRP3200 10:1, CAT II 300Vrms sRP3300 10:1, CAT II 300Vrms |
| Time Delay between Channel (typical) |
500ps |
| Horizontal |
| Sample Rate Range |
3.65Sa/s-2GSa/s (Real-Time), 3.65Sa/s-50GSa/s (Equivalent-time) |
| Waveform Interpolation |
Sin(x)/x |
| Record Length |
Up to 16k samples for half channel 8k samples for each channel |
| Scanning Speed Range (Sec/div) |
1ns/div~50s/div, DS1204B 2ns/div~50s/div, DS1104B 5ns/div~50s/div, DS1074B 1-2-5 Sequence |
| Sample Rate and Delay Time Accuracy |
± 50ppm (any time interval =1ms) |
Delta Time Measurement Accuracy (Full Bandwidth) |
Single: ± (1 sample interval + 50ppm × reading + 0.6 ns) >16 averages: ± (1sample interval + 50ppm × reading + 0.4 ns) |
| Vertical |
| A/D Converter |
8-bit resolution, all channels sample simultaneously |
| Volts/div Range |
2mV/div-10V/div at input BNC |
| Offset Range |
± 40V(245mV/div~10V/div) ± 2V(2mV/div~245mV/div) |
| Equivalent Bandwidth |
70MHz(DS1074B) 100MHz(DS1104B) 200MHz(DS1204B) 60MHz(DS1064B) |
| Single-shot Bandwidth |
70MHz(DS1074B) 100MHz(DS1104B) 200MHz(DS1204B) 60MHz(DS1064B) |
Selectable Analog Bandwidth Limit (typical) |
20MHz |
Lower Frequency Response (AC -3dB) |
≤5Hz (at input BNC) |
Rise Time at BNC (typical) |
<1.75ns, <3.5ns, <5ns, On 200MHz, 100MHz, 70MHz respectively |
| DC Gain Accuracy |
2mV/div~5mV/div: ± 4% (Normal or Average acquisition mode) 10mV/div~10V/div: ± 3% (Normal or Average acquisition mode) |
DC Measurement Accuracy Average Acquisition Mode |
When vertical displacement is zero, and N =16: ± (DC Gain Accuracy× reading+0.1div+1mV) When vertical displacement is not zero, and N =16: ± [DC Gain Accuracy× (reading+ vertical position)+(1% of vertical position)+0.2div] Add 2mV for settings from 1mV/div to 200 mV/div Add 50mV for settings from >200mV/div to 10V/div |
Delta Volts Measurement Accuracy (Average Acquisition Mode) |
Under same setting and condition, the voltage difference (Δ V) between any two points in the waves coming from the average of more than 16 waves have been acquired: ± (DC Gain Accuracy× reading + 0.05 div) |
| Trigger |
| Trigger Sensitivity |
0.1div-1.0div (adjustable) |
| Trigger Level Range |
Internal EXT EXT/5 |
± 6 divisions from center of screen ± 1.2V ± 6V |
Trigger Level Accuracy (typical) applicable for the signal of rising and falling time =20ns |
InternalcEXT EXT/5 |
± (0.3div × V/div)(± 4 divisions from center of screen) ± (6% of setting + 40 mV) ± (6% of setting + 200 mV) |
| Trigger Offset |
In Normal mode: pre-trigger(storage depth/(2× sample) rate), delayed trigger 1s In Slow Scan mode: pre-trigger 6div, delayed trigger 6div |
| Trigger Holdoff Range |
100ns~1.5s |
| HF Rejection |
100kHz ± 20% |
| LF Rejection |
10kHz ± 20% |
Set Level to 50% (typical) |
When input signal frequency ≥50Hz |
| Edge Trigger |
| Edge Trigger Slope |
Rising, Falling, Rising + Falling |
| Pulse Width Trigger |
| Trigger Condition |
( , , =) Positive pulse, ( , , =) Negative pulse |
| Pulse Width Range |
20ns ~10s |
| Video Trigger |
Video Standard Line Frequency |
Support for standard NTSC, PAL and SECAM broadcast systems. Line number range: 1~525 (NTSC) and 1~625 (PAL/SECAM) |
| Pattern Trigger |
| Pattern setup |
H, L, X, , |
| Alternate Trigger |
Trigger on CH1, CH2, CH3, CH4 |
Edge, Pulse Width, Video |
| Measurements |
| Cursor |
Manual |
Voltage difference between cursors (ΔV) Time difference between cursors (ΔT) Reciprocal of ΔT in Hertz (1/ΔT) |
| Track |
Voltage value for Y-axis waveform Time value for X-axis waveform |
| Auto |
Cursors are visible for Automatic Measurement |
| Auto Measure |
Vpp, Vamp, Vmax, Vmin, Vtop, Vbase, Vavg, Vrms, Overshoot, Preshoot, Freq, Period, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, Delay→ A B , Delay A B Phase A B ,Phase A B |
Comparison Table
| Channels |
4 |
4 |
4 |
4 |
| Bandwidth |
70 MHz |
60 MHz |
100 MHz |
200 MHz |
| Real-time Sample Rate |
2 GSa/s |
| Equivalent Sample Rate |
50 GSa/s |
| Waveform Capture Rate |
1000 wfms/s |
| Memory Depth |
8 k |
Comparison Table
| Bandwidth |
200 MHz |
200 MHz |
| Real-time Sample Rate |
2 GSa/s |
2 GSa/s |
| Equivalent Sample Rate |
50 GSa/s |
N/A |
| Memory Depth |
8 k |
2.5 k |
| Trigger Modes |
Edge, Pulse Width, Pattern/TV |
Edge, Pulse Width, Video |
| Display |
QVGA (320 x240), 65, 000 colors, 5.7 TFT LCD |
1/4 VGA passive color LCD |
| Screen Display |
12 div |
10 div |
| Standard Interface |
USB Device, USB Host2, LAN |
USB Device, USB Host |
| Automatic Measurement |
22 (display 18 measure data) |
11 (display 5 measure data) |
| Internal Storage |
10 waveforms/10 setups |
4 waveforms/10 setups |
| USB Storage |
8 bit Bitmap, 24 bit Bitmap, PNG, CSV, Waveform, Setup |
CSV, Setup |
| Pass/Fail Detection |
Yes |
No |
| Waveform recorder/replay |
Yes |
No |
| Adjustable trigger sensitivity |
Yes |
No |
|
|