Protek Z9216 Wide Range LCR Meter

Click Image to Enlarge
Protek Z9216
|
- 0.2% basic accuracy
- Wide measurement range over13 orders of magnitude
- Store and recall 9 instrument setups
- Measurement rates to 20 times per second
- Test frequencies are 100Hz, 120Hz, 1kHz, 10kHz and 100kHz
- Displays component value and Q or Dissipation factor
- Averaging for 2 to 10 measurements
- RS-232 and optional GPIB and Handler interface
- Open and short circuit compensation for accurate zeroing
- Easy to use and calibrate
- Built-in calibration procedures
- Binning capabilities
|
| Model |
Description |
List Price |
Sale Price |
| Z9216 |
High Accuracy (0.05%) LCR Meter |
$1750.00 |
| $1505.00 |  |
|
| Model |
Accessories |
List Price |
Sale Price |
| Z9216-1 |
Radial Fixture Z9216 |
$150.00 |
| $129.00 |  |
|
| Z9216-2 |
Kelvin Clips for Z9216 |
$325.00 |
| $279.50 |  |
|
| Z9216-3 |
SMD Tweezers for Z9216 |
$375.00 |
| $322.50 |  |
|
| Z9216-4 |
GPIB Interface and Handler (installed) |
$350.00 |
| $301.00 |  |
|

Click Image to Enlarge
|

Click Image to Enlarge
|

Click Image to Enlarge
|
| The standard accessory supplied with the Z9216. This unit adapts to the Z9216 input BNC terminals and facilitates easy measurement of Axial or Radial lead components. |
The Kelvin clips provide a 4-wire connection to components that have large or odd shaped leads. This removes any error caused by voltage drops in the leads. |
The SMD tweezers are used to measure small surface mount or odd shaped components. |
|
|
| Abbreviations Used |
L (inductance)
C (capacitance)
R (resistance) |
| Measured Circuit Configurations |
series and parallel |
|
|
|
|
| Measured Parameter (R) |
R + Q |
| Measurement Ranges (R) |
R: 0.0001 W to 2000 MW
Q: 0.00001 to 50 |
| Measured Parameter (L) |
L + Q |
| Measurement Range (L) |
L: 0.0001 µH to 99999 H
Q: 0.0001 to 50 |
| Measured Parameters (C) |
C + D and C + R |
| Measurement Range (C) |
C: 0.0001 pf to 99999 µF
D: 0.00001 to 10
R: 0.00001 KW to 9999 KW |
| Display |
Values, % deviation, or bin number |
|
|
|
|
| Test Frequencies |
100Hz, 120Hz, 1kHz, 10kHz and 100kHz |
| Frequency Accuracy |
£ ±100 PPM |
| Drive Voltages |
Fixed: 0.10, 0.25, 1.0 V RMS
Vernier: 0.1 to 1.0 V RMS (50 mV resolution) |
| Drive Voltage Accuracy |
±2% |
| Measurement Rates |
[For test frequencies of 1kHz or greater}
Slow: 2 measurements/Sec
Medium: 10 measurements/Sec
Fast: 20 measurements/Sec
[For test frequencies of 100Hz and 120Hz]
Slow: 0.6 measurements/Sec
Medium: 2.4 measurements/Sec
Fast: 6 measurements/Sec |
| Bias Voltage |
Internal: +2.0 V DC ±2%
External: 0 to +40 V DC |
| Input Protection |
0.25A/250V Fuse |
| Ranging |
Auto or manual |
| Triggering |
Continuous, manual or remote (from the RS-232, GPIB or handler interface) |
|
|
|
|
| Basic Accuracy |
±0.2% with the following conditions:
1. An ambient temperature of 23°C ±5°C after a 30 minute warm up period.
2. The short and open Cal has been performed.
3. D < 0.1 for capacitance, Q < 0.1 for resistance and Q > 10 for inductance.
The component value, measurement rate and frequency determine the actual measurement accuracy. (See the user manual). |
| Zeroing Correction |
Open and short circuit compensation |
| Remote Operation |
Interfaces: RS-232 (25 pin D female conductor), Standard GPIB and Handler (25 pin D male connector optional) |
|
|
|
|
| AC Voltage Input |
120/220 Volts |
| Frequency |
50/60Hz |
| Power Consumption |
20 Watts |
| Operating Temperature |
0 to 50°C at < 80% Relative Humidity |
| Size |
4.3" H × 14.3" W × 14.5" D |
| Weight |
18 lbs. |
| Supplied Accessories |
Manual, Line cord, Axial lead adapter |
| Optional Accessories |