Protek S2401U Hand-Held DSO/DMM w/USB 50MS/s 1MHz

Click image to enlarge
Protek S2401U
|
|
Features:
- Dual Channel
- 50MS/s sampling rate
- 500mV/Div Vertical sensitivity
- Auto ranging Vertical and Horizontal scales
- Built-in auto/manual ranging, True RMS, 4000 count DMM
- DC to 1MHz bandwidths
- Hand held and battery operated
- Designed to UL3111, CSA C22.2 No 1010 standards
- USB Port, Cable and supplied software
- User-friendly front panel
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| S2401U |
50 Ms/Sec 1MHz Handheld DSO/ DMM with USB |
$399.00 |
| $343.14 |  |
|
Specifications
| Vertical (Oscilloscope) |
| Bandwidth |
1MHz |
| Resolution |
8 bits |
| Number of Channels |
2 |
| Coupling |
AC and DC |
| Input Impedance |
1MW |
| Accuracy |
±3% |
| Max. Input Voltage |
600V DC or AC RMS |
| Vertical Sensitivity |
500mV/Div to 500V/Div in a 1-2-5 sequences |
| Horizontal (Oscilloscope) |
| Sample Rate |
50MS/s single channel 25MS/s dual channel |
| Record Length |
512 bytes single shot and Glitch capture 256 bytes all other modes |
| Samples/Div |
25 samples |
| Update Rate |
Real time |
| Modes |
Single shot, roll mode, normal |
| Accuracy |
±0.01% |
| Sweep Rate |
1µs/Div to 5s/Div in a 1-2-5 sequences |
| Memory |
16 waveforms and setups may be saved in memory |
| Triggering (Oscilloscope) |
| Trigger Source |
CH A, CH B, External |
| Coupling |
AC, DC |
| Trigger sensitivity |
2/20 Division |
| Trigger Modes |
Auto and Normal |
| Slope |
Positive and Negative |
| DC Volts |
| Ranges |
5V, 50V, 500V, 1000V |
| Best Resolution |
1mV |
| Accuracy |
±(0.3% + 3d) |
| Input Impedance |
1MW |
| AC Volts |
| Ranges |
3V, 30V, 300V, 750V |
| Best Resolution |
1mV |
| Accuracy |
±(0.75% + 5d) 40Hz to 450Hz ±(2% + 5d) 450Hz to 5KHz ±(2.5% + 5d) 5KHz to 20KHz |
| Input Impedance |
1MW |
| Max. Input Voltage |
600V DC or AC RMS |
| Ohms |
| Ranges |
5KW, 50KW, 500KW, 5MW |
| Best Resolution |
1W |
| Accuracy |
±(0.5% + 5d) |
| Overload Voltage |
600V DC or AC peak |
| Continuity |
| Test Voltage |
1.7V |
| Threshold |
100 digits |
| Overload Voltage |
600V DC or AC peak |
| Frequency |
| Ranges |
100Hz, 1KHz, 10KHz, 100KHz, 1MHz, 10MHz |
| Best Resolution |
0.01Hz |
| Accuracy |
±(0.05% + 5d) |
| Overload Voltage |
600V DC or AC peak |
| RPM |
| Range |
240 to 60,000 RPM |
| Resolution |
1 RPM |
| Accuracy |
±(0.05% + 5d) |
| Pulse Width |
| Range |
2µs to 500Ms (pulse width > 2µs) |
| Duty Cycle |
Range : 25% to 75% |
| LCD Display |
Size:2.5" x 2.5" |
| General Specifications |
| Power |
3.7V Li-Ion battery pack 120V to 9V @ 1A DC adapter |
| Battery Life |
4 hours without backlight 3 hours with backlight on |
| Display |
132 x 128 Pixel super twist LCD |
| Size |
7.5" (H) x 3.5" (W) 1.57" (D) |
| Weight |
1.5 lbs |
| Standard Accessories |
Manual, Carrying case, Test leads, Holster, USB cable, Software, AC/DC charger and 3.7V Li-Ion Battery pack |
|