  • 0.1Hz to 2GHz Frequency Range
  • Measures Frequency, Period, Time interval, Ratio and Totalize
  • 0.5 PPM temperature stability
  • Channel A and Channel B have variable trigger level controls
  • Large, bright 8 digit LED frequency display along with function and gate time indicators
  • Self check
  • Low pass filters and X10 attenuators
  • All functions selected via tactile switches


Model Description List Price Sale Price
B2000 2GHz Universal Counter - Discontinued - replaced by Protek B3110

Frequency Measurement Channel A Input
Ranges Low Range: 0.1Hz to 10MHz
High Range: 10MHz to 100MHz
Best Resolution Low range: 0.1Hz
High range: 10Hz
Gate Time 0.01s to 10s in 4 decade switch settings
Accuracy ±1 count ± (timebase error) X frequency
Frequency Measurement Channel C Input
Range 90MHz to 2GHz
Best Resolution 10Hz
Gate Times 0.0256s, 0.256s, 2.56s, 25.6s switch selectable
Accuracy ±1 count ± (timebase error) X frequency
Period Measurement Channel A Input
Ranges 100ms to 500ns
Gate Time 0.01s to 10s in 4 switch selectable settings
Best Resolution 100ps
Accuracy ±1 count ± timebase error; ± Trigger error
Minimum Pulse Width 250ns
Totalize Measurement Channel A Input
Frequency Range DC to 10MHz
Count Capacity 0 to 99,999,999
Resolution ±1 input count
Time Interval CH A & CH B Inputs
Range 200ms to 500ns
Accuracy ±1 count ± timebase error ± CH A Trigger error
Best Resolution 100ns
Minimum Pulse Width 250ns
Ratio A/B CH A & CH B Inputs
Range CH A: 10MHz to 100MHz
CH B: 0.1Hz to 10MHz
Input Characteristics Channel A Input
Sensitivity 25mV RMS 0.1Hz to 100MHz
Attenuation X1 or X10
Input Impedance 1MW + 35pF
Coupling DC & AC
Lowpass Filter (-3dB) 10Hz to 100kHz @ X1
Max. Voltage 250V DC or AC RMS
Trigger Level From -350mV DC to +350mV DC
Input Characteristics Channel B Input
Sensitivity 25mV RMS 0.1Hz to 100 MHz
Attenuation 0dB or 20dB
Input Impedance 1MW + 35pF
Coupling AC & DC
Lowpass Filter (-3dB) 10Hz to 100kHz
Max. Voltage 250V DC or AC RMS
Trigger Level From -350mV DC to +350mV DC
Input Characteristics Channel C Input
Sensitivity 50mV RMS, 90MHz to 2GHz
Max. Input Voltage 3V RMS
Input Impedance 50W
Coupling AC
Timebase
Frequency 10MHz & 3.90625MHz
(Temperature controlled Oven)
Stability Long Term: ±3x10-7 per month
Temperature: ±5x10-7, 0 to 30°C
Warm Up Time 20 minutes (25°C)
10MHz Oscillator Output
Output Voltage 1V P-P (open circuit)
Output Impedance 50W
General Specifications
Display 8 Digit LED (14mm)
Power Requirements AC line voltage 100/120/220, 240V ±10%
Power Consumption 15V A, 50/60Hz
Operating Temperature 0 to 40°C
Size 3.4" H x 10.4" W × 9.0" D
Weight 5 lbs.
Supplied Accessories Manual, Line cord, BNC cable




   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET