Protek 608 Digital Multimeter

Click image to enlarge
Protek 608
|
|
Features:
- DC accuracy 0.05%
- Low voltage Ohms measurement and conductance
- Auto and software calibration
- Dual back-lit display and K type thermocouple
- Measures duty cycle, pulse width and conductance
- Compare function for go-no go testing
- Peak detection for capturing high speed signals
- Binary bit expression bargraph
- AC and AC + DC true RMS AC voltage and current measurements
- Auto/manual ranging
- Test zener diodes up to 20 volts
- Min/Max/Avg relative modes
- Memory store and recall
- Fuse protected current ranges
- Cat II 600V and CE approved
|
Additional Images
|

Side-angle View
|

Model & Accessories
|

Manual & Software
|

Computer Port
|

LCD Close-up
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| 608 |
50K count Adv.DMM, True RMS, RS232C |
$199.00 |
| $129.00 |  |
|
| Model |
Accessories |
List Price |
Sale Price |
| TL-501 |
For: B845,CM108/9,D906,D910F,D927,D937,D945, |
$8.00 |
| $6.88 |  |
|
| CB-506 |
For mod #s: 505,506,608,D988 - Discontinued - no replacement |
| HLST-506 |
For: 505,506 |
$10.00 |
| $8.60 |  |
|
| TP-35 |
K Temp probe for D910F,D981,TM1300K,505,506 |
$15.00 |
| $12.90 |  |
|
| CB-35D |
For mod #s: A802,D910F,D981,6500,6800 - Discontinued - no replacement |
| TL-102 |
For: A403,A402Z,D901 |
$8.00 |
| $6.88 |  |
|
Specifications
| DC Volts |
| Ranges |
5V, 50V, 500V, 1000V |
| Best Resolution |
100µV |
| Accuracy |
±0.05% + 5D |
| mV DC |
| Ranges |
500 mV to 2500mV |
| Best Resolution |
10µV |
| Accuracy |
±0.05% + 5D |
| AC and (AC+DC) mV |
| Ranges |
500mV |
| Best Resolution |
10µV |
| Accuracy |
AC mV: ±0.75% + 20D (AC + DC) mV: ±1.5% + 50D |
| AC Bandwidth |
50Hz to 20kHz |
| AC and (AC+DC) Volts |
| Ranges |
5V, 50V, 500V, 750V |
| Best Resolution |
100µV |
| Accuracy |
AC Volt: ±0.75% + 20D (AC + DC)Volts: ±2.0% + 50D |
| Crest Factor |
Sine wave: 1.414 |
| DC CURRENT |
| Ranges |
5000µA, 500mA, 10 Amps |
| Best Resolution |
0.1µA |
| Accuracy |
±0.2% + 5D |
| AC and (AC+DC) AMPS |
| Ranges |
5000µA, 500mA, 10A |
| Best Resolution |
0.1µA |
| Accuracy |
AC Amps: ±0.75% + 20D, 50Hz to 1kHz (AC + DC) Amps: ±1.5% + 50D, DC to 1kHz |
| Resistance (50 Ohm range is 5,000 count) |
| Ranges |
50W, 5KW, 50KW, 500KW, 5MW, 50MW |
| Best Resolution |
10mW |
| Accuracy |
±0.2% + 5D |
| Resistance Lo Ohms (All ranges are 5,000 count) |
| Ranges |
5KW, 50KW, 500KW; 5MW, 50MW |
| Best Resolution |
1W |
| Accuracy |
±0.5% + 5D |
| Conductance (5,000 count) |
| Range |
500nS |
| Resolution |
0.1nS |
| Accuracy |
±3% + 5D |
| Capacitance (All ranges are 5,000 count) |
| Ranges |
5nF, 50nF, 500nF, 5µF, 50µF, 500µF, 5000µF |
| Best Resolution |
1pF |
| Accuracy |
±2% + 5D |
| Zener Diode Test |
| Range |
25.000 V Approx. |
| Accuracy |
±5% + 10D |
| Test |
15V to 22V |
| Continuity |
| Ranges |
5KW, 50KW, 500KW, 5MW |
| Buzzer |
Will sound at: < 0.1% of full scale of each range |
| Temperature |
| Ranges |
-20 to 1200°C, -4 to 2100°F, 253 to 1423°K |
| Display |
°C, °F, °K |
| Resolution |
0.1° |
| Accuracy |
±2°C 0 to 150°C: ±3°C |
| Frequency (50Hz & 500Hz ranges are 5,000 count) |
| Ranges |
50Hz, 500Hz, 50kHz, 500kHz, 5MHz |
| Best Resolution |
0.01Hz |
| Input Sensitivity |
2V RMS |
| Accuracy |
±0.01% + 5D |
| Pulse Width |
| Range |
200.01ms |
| Best Resolution |
10 µs |
| Accuracy |
±0.1% + 5D |
| Duty Cycle |
| Range |
0 to 100% |
| Resolution |
0.01% |
| Accuracy |
±0.1% + 5D |
| Peak Hold |
| Accuracy |
10% of peak for a duration of > 5mS |
| General Specifications |
| Operating System |
Windows(r) 95/98/ME/XP/2000 |
| Update Rates |
2/s |
| RS-232 Output Medium |
Infrared |
| Operating Temperature |
0 to 40°C at 80% relative humidity |
| Power |
9 Volt battery @ 36 hours of continuous operation |
| Size |
8.0" H × 3.7" W × 1.7" D (without holster) |
| Weight |
14.7 oz. |
| Standard Accessories |
Manual, Protective holster, Safety probes, Temperature adapter and Probe, RS-232 cable, CD ROM |
|