Protek 506 Digital Multimeter

Click Image to Enlarge
Protek 506
|
- Dual display for Frequency, AC voltage and Temperature measurements
- True RMS AC Voltage, Current and DB Readings
- RS-232 interface & software, 10 location memory
- Min, Max, Avg and Relative modes
- Capacitance, Inductance, Frequency and Temp measurements
- Square wave generator, logic function and back light
|
| Model |
Description |
List Price |
Sale Price |
| 506 |
3-3/4 Digit,4K count, Dual Disp.,True RMS,RS232C |
$169.00 |
| $145.34 |  |
|
| Model |
Accessories |
List Price |
Sale Price |
| TL-501 |
For: B845,CM108/9,D906,D910F,D927,D937,D945, |
$8.00 |
| $6.88 |  |
|
| CB-506 |
For mod #s: 505,506,608,D988 |
$20.00 |
| $17.20 |  |
|
| HLST-506 |
For: 505,506 - Discontinued - no replacement |
| TP-35 |
K Temp probe for D910F,D981,TM1300K,505,506 |
$15.00 |
| $12.90 |  |
|
| CB-35D |
For mod #s: A802,D910F,D981,6500,6800 - Discontinued - no replacement |
| TL-102 |
For: A403,A402Z,D901 |
$8.00 |
| $6.88 |  |
|
|
|
| Ranges (5) |
400mV to 1000V |
| Best Resolution |
0.1mV |
| Accuracy |
± (0.5% Rdg + 2D) |
|
|
|
|
| Ranges (5) |
400mV to 750V |
| Best Resolution |
0.1mV |
| Accuracy |
± (1.5% Rdg + 5D) |
|
|
|
|
| Ranges |
400µA, 400mA, 20A |
| Best Resolution |
0.1µA |
| Accuracy |
± (1% Rdg + 2D) |
|
|
|
|
| Ranges |
400µA, 400mA, 20A |
| Best Resolution |
0.1µA |
| Accuracy |
± (1.5% Rdg + 2D), 50Hz to 100Hz |
|
|
|
|
| Ranges (6) |
400W to 40MW |
| Best Resolution |
0.1W |
| Accuracy |
± (0.5% Rdg + 2D) |
|
|
|
|
| Ranges (4) |
-31.6 to + 59.71dB |
| Best Accuracy |
±0.5dB |
|
|
|
|
| Buzzer |
Sound at < 100W . |
| Display Will Read |
Shrt when R < 100W
Open when R > 100W |
|
|
|
|
| Display Will Read |
Shrt when V < 0.5V
Good when V = 0.5V to 1V
Open when V > 1V |
|
|
|
|
| Ranges (4) |
10kHz to 10MHz |
| Best Resolution |
1Hz |
| Accuracy |
± (0.01% Rdg ± 1D) |
| Sensitivity |
1.5V RMS |
|
|
|
|
| Range |
-17 to 1200°C (0 to 2000°F) |
| Resolution |
1°C and 1°F |
| Accuracy |
± (3% Rdg + 3D) |
|
|
|
|
| TLL Level Display Will Read |
Lo when V is < 0.8V
Hi when V is > 2.0V
W when V is 0.8V to 2.0V |
|
|
|
|
| Range |
0 to 100µF |
| Resolution |
0.01µF |
| Accuracy |
± (3% Rdg + 5D) |
|
|
|
|
| Range |
0 to 100H |
| Resolution |
0.01H |
|
|
|
|
| Signal Out |
2048Hz, 4096Hz, 8192Hz Square wave |
| Timer Range |
1 second to 10 hours |
| RS-232 Interface |
1200bps, 9 Pin Connector |
|
|
|
|
| Size |
8.0" H × 3.6" W × 1.5" D |
| Weight |
1 lb. |
| Power |
9V battery |
| Supplied Accessories |
Manual, Test leads, Holster, Temp adapter, "K" type temp probe, RS-232 cable and Software |
|
|