Features:
  • True ± 0.025% of reading
  • Read and Source 0.000 to 50.000 mA
  • Display current or -25.00 to 125.00% of 4-20mA or 10-50mA
  • Bar graph displays % of 4-20mA or 10-50 mA
  • Read 0.00 to 60.00 volts with 2X over range ability
  • Simulate 2-Wire Transmitters
  • Read 0.00 to ± 30.00 VDC with 4X over range ability
  • Source 0.000 to 24.000 VDC with up to 20mA output
  • Direct Calibration 1.000V to 5.000V
  • Loop Compliance Voltage >43 Volts
  • Optional Analog Ooutput for chart recorders & Data loggers
  • Auto Step or Ramp with HIGH accuracy and repeatability designed in collaboration with Nuclear plants
  • Selectable step sizes, time in-between steps & soak time
  • Stop watch like EZ-Check switch
  • Full 5 Digit Display
  • Fuseless protection from accidental connection to 240 volts AC/DC
  • Rugged handheld enclosure with optional lanyard and Velcro hand strap
  • Uses 4 AA alkaline batteries
  • Superior battery life of 40 hours under typical continuous usage
  • Easy access to battery compartment
  • NIST Traceable Test Data, A/C Adaptor, and Carrying Case included FREE
  • NIST Traceable Calibration Certificate included FREE



  Description

The Practical Instrument Electronics Model 535 Dual Range Loop Calibrator makes testing, troubleshooting, and calibrating your 4-20 and 10-50 milliamp process loops easy as pie. Change ranges in seconds - the Model 535 is two calibrators in one convenient package. Easily recall min/max readings with the EZ-Check? feature. Powerful manual and automatic stepping and ramping features are found on the dual-action EZ-Step? Switch providing one-handed or hands-free operation. Independent step size, step time, and soak time parameters offer the most step and ramp flexibility of any calibrator in its class.

On power up you can select 4-20 or 10-50 mA. The EZ-Dial knob and EZ-Check switch are all that's needed to make quick adjustments or set 0% or 100% of full scale. The EZ-Step button provides one-handed stepping. Automatic stepping and ramping modes allow hands-free testing and calibration of the process loop with HIGH accuracy and repeatability designed in collaboration with Nuclear plants.

The model 535 offers the optional analog output of 10mV/mA proportional output for connection to chart recorders and data loggers. With the Model 535, calibration is easy as PIE.




  Models, Options, & Accessories


Model Description List Price Sale Price
535 4-20 10-50 mA Loop Calibrator (Includes Carrying Case, AC Adaptor & Wire Kit) $2750.00
$2612.50 
535-EW 4-20 10-50 mA Loop Calibrator (Includes Carrying Case, AC Adaptor & Wire Kit) $3100.00
$2945.00 
535-RW 4-20 10-50 mA Loop Calibrator (Includes Carrying Case, AC Adaptor & Wire Kit) $3100.00
$2945.00 
Model Accessories List Price Sale Price
020-0102 AC Adaptor for model 535 (100 - 120V, 60Hz) $50.00
$47.50 
020-0204 Carrying Case w/PIE LOGO for models 530, 532, 535 & 541 $50.00
$47.50 

ER = Extended Warranty
RW = Replacement Warranty



  Specifications

General Specifications: (Unless otherwise indicated all specifications are rated from a nominal 23 °C, 70 % RH for 1 year from calibration)
Temperature Range -25 to 60 °C (-5 to 140 °F)
Storage Temperature Range -30 to 60 °C (-22 to 140 °F)
Relative Humidity Range 10 % 10 %
Size 7.00 X 3.30 X 2.21 inches (177.8 x 83.8 x 56.1mm)
Weight 14.0 oz (397 grams)
Battery 4 AA Alkaline, 120 VAC 50/60 Hz AC adaptor included
Miscellaneous Low battery indication with nominal 1 hour of operation left
Over-voltage protection to 120 Vrms (rated for 30 seconds) or 240 Vrms (rated for 15 seconds)
Bar graph display with 1% resolution of 4-20/10-50 mA signal scale
High contrast graphic liquid crystal display with 0.45 (11.4 mm) high digits
Model 535A Analog Output 10 mV/mA ±(0.1% + 0.04mV), 5 ppm/°C
Common Specifications for all current modes:
Ranges 0.000 to 24.000 mA, -25.00 to 125.00% of 4-20 mA
0.000 to 52.000 mA, -25.00 to 105.00% of 10-50 mA
Accuracy = ± (0.025 % of reading + 0.004 mA)
Temperature effect < ± 50 ppm/°C of Range
Resolution 0.001 mA and 0.01 %
Step/Ramp Timebase Accuracy 0.01% of 4.9152 MHz
Source/Power and Measure 2-Wire Transmitter Specifications:
Loop Compliance Voltage ±0.25°C (0.5°F)
Loop compliance voltage > 43 Volts
Loop drive capability 1200 ω at 20 mA/800 ω at 50 mA for entire battery life
Miscellaneous Open loop or out of compliance conditions are indicated by appropriate error display

Battery Life in:
Source mode > 18 hrs at 12 mA/= 9 hrs at 30 mA nominal (100 ω load)
Power measure > 10 hrs at 12 mA/= 5 hrs at 30 mA nominal (100 ω load)

Selectable EZ-Step(s) for Source Mode/2-Wire Transmitter Simulation:
2 to 16 selectable step settings
Step size is determined by the selected high & low ranges
Selectable time settings for stepping and soak:
STEP: 5 to 900 seconds
SOAK: 0 to 900 seconds
Read mA Specifications:
Voltage burden < 2V
Overload/Current limit protection < 24 mA (4-20 range)/ = 52.5 mA (10-50 range) nominal
Battery life > 40 hours typical
Source/Power and Measure 2-Wire Transmitter Specifications:
Overload/Current Limit Protection < 24 mA (4-20 range)/ < 52.5 mA (10-50 range) nominal
Loop Voltage Limits 2-90 VDC
Miscellaneous Open loop or out of compliance conditions are indicated by appropriate error display

Battery life = 40 hour typical
Selectable EZ-Step(s) for Source Mode/2-Wire Transmitter Simulation:
2 to 16 selectable step settings

Step size is determined by the selected high & low ranges
Selectable time settings for stepping and soak:
STEP: 5 to 900 seconds SOAK: 0 to 900 seconds
Read Voltage Specifications:
Range 0.00 to 30.00 VDC (with 4X over range)
Resolutions 0.01 VDC
Temperature Effect < ± 200 ppm/°C of range
Input Resistance > 1 Mω
Accuracy 0.00 to 30.00 VDC < ± (0.1 % of reading ±0.1 V)
Source Voltage Specifications:
Source Range 0.000 to 24.000 VDC
Output Resistance <0.3ω
Source Current > 20.000 mA Ordering
Accuracy <±(0.025%RDG + 0.004 V) ±50ppm/°C of range



 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 




Fluke Sponsored March Madness Bracket Challenge

Quote Request

We Take POs, How To Order

Free Shipping on Select Premier Lines










Live chat by BoldChat
Let our engineers and cs staff help!
Need a quote? Need to check stock?
Have a technical question? No problem.
We are here to help.