Sampling |
Sampling modes | Normal sampling Peak detection Average value |
Sampling rate | 100 MSa/s |
Input |
Input coupling | DC, AC |
Input impedance | 1MΩ?2% connected in parallel with 20pF?3pF |
Probe attenuation coefficient | 1X, 10X, 100X, 1000X |
Max. Input voltage | 400V (peak) |
Channel delay time (typical) | 150ps |
Horizontal |
Sampling rate range | 10S/s 100MS/s |
Waveform interpolation | sin x / x |
Record length | 6K points on each channel |
Scanning speed range S/div | 5ns/div 5s/div, stepping in the ?1-2.5-5? mode. |
Sampling rate and relay time accuracy | ?100ppm(any time interval which is equal to or larger than 1ms) |
Time interval (T)measurement accuracy full bandwidth | Single: ?(1 sampling interval time+100ppm?reading+0.6ns) >average 16 : ?(1 sampling interval time +100ppm?reading+0.4ns) |
Vertical |
Analog digital converter A/D | With the resolution of 8 bits, make sampling on both channels synchronously. |
Sensitivity range V/div | 5mV/div 5V/div at the input BNC |
Displacement range | ±50V(500mV 5V), ±1V(5mV 200mV) |
Analog bandwidth | 20M |
Single bandwidth | Full bandwidth |
Low frequency response AD coupling, -3dB | ≥5Hz at the BNC |
Rise time typical one at the BNC | 17.5ns |
DC gain accuracy | ±5% |
DC measurement accuracy average value sampling mode | The voltage difference (V) between any two points on the waveform after averaging the captured waveforms more than16: ±(5% reading + 0.05 divisions). |
Trigger |
Trigger sensitivity Edge triggering | DC coupling : CH1 and CH2: 1div(DC full bandwidth) AC coupling : Same as the DC coupling when it is equal to or larger than 50Hz. |
Triggering lever range | ?6 divisions from the screen center |
Triggering level accuracy (typical) which is applicable to the signal with rise and fall time equal to or longer than 20ns | ?0.3 divisions |
Trigger displacement | 655 divisions for pre-triggering and 4 divisions for post- triggering |
Make a 50% level setting (Typical) | Operation with the input signal frequency equal to or larger than 50Hz. |
Trigger sensitivity (Video triggering and typical mode) | 2 divisions of peak-to-peak value |
Signal system and line/field frequency (Video triggering mode) | Support the NTSC, PAL and SECAM broadcasting systems of any field or line frequency. |
Measurement |
Cursor measurement | Voltage difference (V) and time difference (T) between cursors |
Auto measurement | Peak-to-peak value, average value, root mean square value, frequency and cycle. |
Probe |
Bandwidth 1X position | Up to 6 MHz (DC) |
Bandwidth 10X position | Up to full bandwidth (DC) |
Attenuation rate 1 to 1 |
Compensation range | 10pf 35pf |
Input resistance | 1MΩ?2 |
Input impendence | 85pf 115pf |
Input voltage | 150 V DC |
Attenuation rate 10 to 1 |
Compensation range | 10pf 35pf |
Input resistance | 10MΩ?2 |
Input impendence | 14.5pf 17.5pf |
Input voltage | 300 V DC |