Minolta CR-410 Colorimeter

Click image to enlarge
|
|
Features:
- Stand Alone Measuring Head-The measuring
head is detachable from the data processor. Now you can take
measurements directly with the head alone. You can also connect
the measuring head directly to a PC. Simply install our optional
software, and your PC can function as the data processor.
- User-defined Evaluation Formulas-The CR-400
Series features a Users index function that allows you to configure
the evaluation formula and color calculation formula as desired.
This feature is intended to meet the needs of color-control
applications in which industry specific or customized evaluation
formulas are used, instead of the versatile color system and
standard evaluation formula such as L*a*b*
- Full Data Compatibility with CR-300 Series-To
ensure data compatibility, the CR-400 Series utilizes the same
illumination-viewing optical system as the convention CR-300
series. As a result, those upgrading from the preceding model
can make full use of their existing data.
- Variety of Accessories-A varied selection
of accessories are available to accommodate various types of
targets including powder, paste and opaque liquid. All accessories
are compatible with the CR-300 series.
|
Description
| The NEW CR-400 Series Colorimeter –
all the rugged reliability and functions of the popular CR-300 Series,
in an ultramodern, easier to use, compact design. Available with
8mm aperture (CR-400) and 50mm aperture (CR-410). Imagine holding
sophisticated colorimetric measurement capabilities in just one
hand! With the new CR-400 colorimeter, you can. All the capabilities
you need to measure, to compare, and to Pass/Fail up to 100 targets
and 1000 samples are engineered into the new lightweight, stand-alone,
measuring head. Available in a choice of apertures (8mm or 50mm),
the CR-400 Series is ideal for measuring reflected color and color
difference of ingredients, raw materials, finished products, powders,
pastes, and opaque liquids. And the CR-400 Series is totally data-compatible
with the CR-300 series colorimeters. Color inspect, sort, select,
classify, or grade product anywhere – only with the Konica
Minolta CR-400 Series of Colorimeters. |
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| CR-410 |
Please call or email us for pricing and availability. |
| CR-400 |
Please call or email us for pricing and availability. |
| Model |
Accessories |
List Price |
Sale Price |
| CR-A103 |
Please call or email us for pricing and availability. |
| CR-A101 |
Please call or email us for pricing and availability. |
| CR-A102 |
Please call or email us for pricing and availability. |
| CR-A50 |
Please call or email us for pricing and availability. |
| CR-A52 |
Please call or email us for pricing and availability. |
| CR-A43 |
Please call or email us for pricing and availability. |
| CR-A33a |
Please call or email us for pricing and availability. |
| CR-A33c |
Please call or email us for pricing and availability. |
| CR-A33d |
Please call or email us for pricing and availability. |
| CR-A33f |
Please call or email us for pricing and availability. |
| CR-A12 |
Please call or email us for pricing and availability. |
| AC-A17 |
Please call or email us for pricing and availability. |
| CR-A73 |
Please call or email us for pricing and availability. |
| DP-A22 |
ROLL PAPER DP-A22 (5 ROLLS), Part No: 1840-711 |
| $50.00 |  |
|
Specifications
| Name |
Chroma Meter Measuring Head |
| Model |
CR-410 |
| HeadIlluminating/Viewing system |
Wide area illumination/0 viewing angle (specular
component included) |
| Detector |
Silicone Photo Cells (6) |
| Display Range |
Y:0.01 to 160.00% (reflectance) |
| Light Source |
Pulsed xenon lamp |
| Measurement time |
1 second |
| Minimum measurement interval |
3 seconds |
| Battery performance |
Approx. 800 measurements (when using batteries
under Minolta's testing conditions) |
| Measurement/illumination area |
ø50/ø53 |
| Repeatability |
Within ΔE*ab0.07 standard deviation
(when the white calibration plate is measured 30 times at intervals
of 10 seconds) |
| Inter-Instrument Agreement |
ΔE*ab:within 0.8 Average of 12 BCRA
series II colors |
| Observer |
2 degrees closely matches CIE 1931 standard
observers (x2, y z) |
| Illuminant *1 |
C, D65 |
| Display *1 |
Chroma Values, color difference values, PASS/WARN/FAIL
display |
| Tolerance Judgment *1 |
Color difference tolerance (box tolerance
and elliptical tolerance) |
| Color space/Colorimetric data |
XYZ, Yxy, L*a*b*, Hunter Lab, L*C*h, Munsell(only
illuminant C) CMC (l:c), CIE 1994, Lab99, LCh99, CIE2000, CIE WI.Tw
(only illuminant D65) WI ASTM E313 (only illuminant C), YI ASTM
D1925 (only illuminant C), YI ASTM E313 (only illuminant C) User
index (up to six can be registered from computer) |
| Languages |
Operating Keys: English
LCD: English (default)
(LCD: German, French, Italian, Spanish, Japanese) *1 |
| Storable data sets |
1000 (measuring head and data processor save
different data |
| Color difference target colors |
100 |
| Calibration channels *1 |
20 Channels(ch00: white calibration, ch01
to ch19: user calibration) |
| Display |
Dot-matrix LCD with back light(15 chars x
9 lines + 1 line for icon display) |
| Interface |
RS-232C compliant (for data processor/PC)
*Baud rate: 4800, 9600, 19200 (bps) set at 9600 bps when shipped
from factory |
| Power Source |
4 AAA size alkaline or Ni-MH batteries,
AC adapter (AC-A17) AC120V~50-60Hz 0.4A (for N.America Japan)
AC230V~50-60Hz 0.4A (for worldwide except N. America) |
| Size |
102(W) x 244(H) x 63(D)mm |
| Weight |
Approx. 570g
(including 4AAA size batteries and not including RS-232C cable) |
| Operating Environment |
Temperature: 0 to 40C, Relative humidity:
85% or less with no condensation, Installation category: II, Pollution
degree:2 |
| Storage Environment |
Temperature:-20 to 40C, Relative humidity:
85% or less with no condensation |
| Other |
LCD back light ON/OFF function (when ON,
back light stays ON for 30 seconds after last key or measurement
operation) |
*1 indicates when connected to the Data Processor
or when not set using the Data Processor or the optional software, that
some of the functions are not available when the measuring head is not
connected.
| Name |
Data Processor |
| Model |
DP-400 |
| Display Range |
Y:0.01 to 160.00% (reflectance) |
| Measurement time *2 |
1 Second |
| Minimum measurement interval |
3 Seconds |
| Battery Performance |
Approx. 800 measurements (when using batteries under Minolta's testing conditions) |
| Illuminants |
C, D65 |
| Display |
Chroma values, color difference values, color difference graphs, PASS/WARN/FAIL display |
| Tolerance Judgment *2 |
Color difference tolerance (box tolerance and elliptical tolerance) Only for display function |
| Color space/Colorimetric data |
XYZ, Yxy, L*a*b*, Hunter Lab, L*C*h, Munsell(only illuminant C) CMC (l:c), CIE 1994, Lab99, LCH99, CIE2000, CIE WI.Tw (only illuminant D65) WI ASTM E313 (only illuminant C), YI ASTM D1925 (only illuminant C), YI ASTM E313 (only illuminant C) User index (up to six registered in the Measuring head can be used) |
| Languages |
Operating keys: English, LCD :English (default), German, French, Italian, Spanish, Japanese |
| Storable data sets |
Max. 2000 pieces of data (divisible into 100 pages) Deletion and Undoing selected stored data (one piece of data or all data) are possible |
| Color difference target colors *2 |
Only for the operating function (100 pieces of data when the measuring head is connected; input of measurement values or numeric) (independent of page function) |
| Calibration Channels *2 |
Only for the operating function (20 channels whent he measuring head is connected) (ch00: white calibration;ch01 to ch19: user calibration) |
| Page function |
100 pages |
| Display |
Dot-matrix LCD with back light (16 chars x 9 lines +1 line for icon display) Contrast adjustment |
| Printer |
384 dot line thermal printer (can also print graphs) Automatically prints out all measurement results (can be set not to print) |
| Statistical Function |
Maximum, minimum, average, and standard deviation |
| Automatic measurement *2 |
Date and time display: year, month, day, hour, minute Timer: 3 seconds to 99 minutes. (Some measurement modes require more than 3 seconds). |
| Interface |
RS-232C compliant Baud rate (bps) : 19200 fixed (when connected to PC) When measuring head is connected baud rate is automatically set to that of the measurement head |
| Power Source |
4 AAA size alkaline or NI-MH batteries, AC adapter (AC-A17) AC120V~50-60Hz 0.4A (for N. America and Japan) AC230V~50-60Hz 0.4A (for worldwide except N. America) |
| Size |
100 (W) x 73(H) x 255 (D)mm |
| Weight |
Approx. 600g (not including batteries and paper) |
| Operating Environment |
Temperature: 0 to 40°C, Relative humidity: 85% or less with no condensation, Installation category: II, Pollution degree: 2 |
| Storage Environment |
Temperature : -20 to 40°C, Relative humidity :85% or less with no condensation |
| Other |
User calibration function (multi-calibration/manual
calibration) *2, Measurements for automatic
average function, Print ON/OFF function, CR-400 measurement data
import function *2, All color space
print ON/OFF function, Data protection ON/OFF function. Back light
ON/OFF function. Buzzer ON/OFF function. Display color limit function,
Remote mode (stored data output), Character input function (alphanumeric) |
*2 indicates that part of or all functions
are not available when the measurement head is not connected.
|