Minolta CC-110 CRT Convergence Meter

Click image to enlarge
|
|
Features:
- CRT misconvergence can be controlled numerically
- Measurement of TVs with phosphor pitches from 0.53 to 1.30mm
- Either crosshatch or dot test patterns can be used for measurement
- Measurements are performed using a white pattern (simultaneous emission of R, G, and B)
- Simultaneous measurement of horizontal and vertical misconvergence
- Misconvergence can be displayed as either x and y values or as vector angle and magnitude
- Measurements can be taken at screen perimeter (within 10mm of corner)
- Multi-pattern measurements, using smaller pattern interval, allows measurements to be taken quickly without requiring exact position of measuring head
- Automatic averaging of 3 to 5 measurements
- Warning LED lights if measurements exceed limit values
- Standard RS-232C interface
- Internal function automatically synchronizes measurement with phosphor emission, eliminating requirement for external synchronization signal.
Applications:
- Research, development, quality control and inspection by consumer TV and HDTV manufacturers.
|
Description
|
The Minolta CRT Convergence Meter CC-110 performs high accuracy measurements of the degree of misconvergence of TVs and HDTVs for production quality control and monitor inspection. Horizontal and vertical misconvergence of all three phosphor colors are measured simultaneously. Multi-pattern measurements, measurement averaging, and tolerance checking are also possible. In addition, data communication and remote control can be performed via the RS-232C terminal. Optional CC-S10 software adds additional graphics and features.
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| CC-110 |
CRT Convergence Meter CC-110, Part No: 1835-168 |
| Call |  |
|
Specifications
| Model |
CC-100 CRT Convergence Meter |
| Test Pattern |
Type of pattern: Crosshatch; dot; vertical or horizontal line Pattern display: White (simultaneous emission of all three colors: R, G, and B); emission of any two colors |
| Evaluation Method |
Center of luminance |
| Display Modes |
R, G, or B standard color; display of maximum value; vector display |
| Accuracy/Absolute value |
±5%±0.05mm |
| Display Resolution |
0.01mm 10° for angle of vector display |
| Repeatability |
±0.05mm |
| Measurement rate |
Approx once every 3 to 4 seconds (NORMAL measurement area) Once every 4 to 6 seconds (WIDE measurement area) |
| Faceplate Thickness |
9 to 27mm |
| Phosphor Type |
RGB; RGLB |
| Phosphor Pitch |
0.53 to 1.3mm (in two ranges) |
| Luminance range |
50 to 1000cd/m2 |
| Operating system |
Interlace; non-interlace |
| Vertical scanning frequency |
50 to 120Hz |
| Other functions |
Tolerance checking (2 values); display of average value (3 measurements or 5 measurements); multi-pattern function |
| Operating environment conditions |
0 to 40°C (32 to 104°F); relative humidity less than 85% at 35°C (95°F) with no condensation Maximum altitude: 2000m Installation category: 2 Pollution degree: 1 |
| Storage temperature range |
-20 to 55°C (-4 to 131°F); relative humidity less than 85% at 35°C (95°F) with no condensation |
| Inputs/Outputs |
Synchronization signal input; color monitor signal (NTSC composite or RGB) output; RS-232C input and output; external measuring switch input |
| Power |
For N. America: AC 100 to 120V, 50 to 60Hz, 40VA For Europe: AC 200 to 240V, 50 to 60Hz, 50VA |
| Dimensions (WxHxD) |
Main unit: 400 x 112 x 297mm (15-3/4 x 11-11/16 x 4-3/8 in.) Measuring head: 62 x 224 x 69mm (2-7/16 x 8-13/16 x 2-3/4 in.) Cord length (between main unit and measuring head): 2m (6.6 ft.) |
| Weight |
Main unit: 6.4kg (14.1 lb.) Measuring head: 780g (1.7 lb.) |
|