Our agents are available:
9:00 AM - 6:00 PM EST
Megger MIT310A-EN 1000V Insulation and Continuity Tester
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   



Megger MIT310A-EN 1000V Insulation and Continuity Tester




Click image to enlarge

 Megger MIT310A-EN

Features:
  • Conventional moving-coil meter movement in place of the digital display
  • Extremely easy to use
  • Tough rubber armoured case
  • Self contained protective cover
  • Live circuit warning
  • Weatherproof to IP54
  • Intelligent Safety System for protection.
  • Result storage and downloading
  • Download software included
  • USB interface



  Description

The Megger MIT310A

Developed specifically to meet the needs of today's electrical contractors, the new MIT310A insulation and continuity tester from Megger is not only durable and easy to use, but also incorporates a comprehensive set of features designed to ensure operator safety, even under conditions of accidental misuse.

The MIT310A is for users who prefer a true analogue device. This tester has features similar to those of the MIT310, but with a conventional moving-coil meter movement in place of the digital display. Black decals on a whitebackground give high contrast, even in poor light conditions.
In addition, the tester features rugged construction with an impact-resistant, rubber-overmoulded case and innovative circuitry, guaranteeing high accuracy combined with stability of calibration.

The MIT310A offers automatic discharge of the circuit after testing, audible and visual warning if the test probes are applied to a live circuit, and a test inhibit feature which operates automatically under live circuit conditions. The unit also conforms fully to IEC 61010-1 for use in Category III 600V applications, and provides all of the facilities needed to meet insulation testing requirements relating to the current edition of the IEE Wiring Regulations.


Combining Safety with Durability:


Tough

  • Designed to take the bashing that testers receive on site,the Megger MIT insulation testers are rubber armoured.
  • The rigid display cover folds right out of the way during testing and locks down to protect the display when it is finished.

Simple to use

  • No buried functions mean it is obvious how to use the Megger MIT.
  • Colour coded ranges help test selection, reducing testing time and help with fault location.
  • A user guide in the lid provides all the basic information.

Hands free use

  • It hangs comfortably around the neck for hands-free use because the instrument is carefully balanced.
  • Continuity and buzzer testing starts automatically on connection to the circuit.

Safety features To protect the user and the tester from incorrect use the MIT series all have an extensive range of features known as the Megger Intelligent Safety System including:

  • Safety Interlock – prevents unsafe connection of test leads
  • Safe contact detectors – Even if the MIT is connected to alive circuit hilst on continuity setting the tester will remain safe and not be damaged.
  • Live voltage warning – alerts the operator when a circuit voltage over 2 5 V exists.
  • Safety lockout – Prevents the test from operating when the circuit voltage is >50 V.
  • Continuity check – prevents a continuity test or buzzer test on a live circuit.

Functionalilty

  • A Job reference number can be selected for a range of results, allowing separate locations to be tested with the same tester and easily separated when downloaded.
  • A memory bar graph acts as a ‘Fuel Gauge’ showing how much memory has been used
  • Test results are downloaded to CSV (Coma Separated Variable) spreadsheets, and can be imported into Microsoft Excel. If certificates or reports are required, the results can be downloaded directly into Megger Powersuite Professional with a range of features for creating professionally finished documentation.

Applications

  • The MIT300 series has applications in all aspects of domestic, commercial and industrial electrical contracting, building maintenance, testing, inspection and servicing.
  • Combining both Insulation testing and continuity testing, each instrument caters for all aspects of fixed wiring installations.
  • All the MIT instruments meet or exceed the UK and International Wiring Regulations, including requirements of BS7671 and VDE 0413 parts 1 and 4, HD 384, IEC 364, NFC15-100, N N3140, ES59009 and EN 61557.
  • In addition the range meets the requirements of IEC 61010- 1 for safe connection to a 440 V Installation Category III supply (600 V Phase to Earth).
  • All the MIT300 range is supplied with a full 3 years warranty.



  Comparison Guide


MIT300 SERIES BENEFITS
Insulation testing
MIT300 MIT310 MIT310A
Analogue
MIT320 MIT330
250 V
500 V
1000 V  
Test range 999 MΩ 999 MΩ 999 MΩ 999 MΩ 999 MΩ
Insulation limit alarm (0.01 MΩ to 999 MΩ)      
Continuity testing          
Continuity to 100 Ω
Continuity buzzer
Lead null to 9ohms 0.5 Ω
Adjustable buzzer 1 to 20 Ω      
Audible buzzer disable      
Voltage measurement          
Volts AC/DC   600 V 600 V 600 V 600 V
Resistance measurement          
10 Ω to 1 MΩ range      
Features          
Voltage warning        
Default voltmeter  
Backlit display      
Backlight selector ranges      
Locking test button
Auto powerdown  
Switched test probe      
IP54 weatherproof
Accepts rechargeable batteries
1000 Test result storage        
Downloading        
Calibration certificate  
3 years warranty



  Models, Options, & Accessories


Model Description List Price Sale Price
MIT310A-EN Analog Hand-Held Megger Insulation Tester; 250,500, 1000 V
$475.00 
MIT300-EN Analog/Digital Hand-Held Megger Insulation Tester; 250 & 500 V
$410.00 
MIT310-EN Analog/Digital Hand-Held Megger Insulation Tester; 250, 500 & 1000 V
$470.00 
MIT320-EN Analog/Digital Hand-Held Megger Insulation Tester; 250, 500 & 1000 V
$555.00 
MIT330-EN Analog/Digital Hand-Held Megger Insulation Tester; 250, 500 & 1000 V
$610.00 



  Specifications

Insulation ranges
Nominal Test Voltage 1000 V, 500 V, 250 V (d.c.)
Measuring Range
All instruments 10 k½ - 999 M½ on all ranges
Short Circuit Current 1.5 mA nominal
Test Current on Load 1 mA at min. pass values of insulation (as specified in BS7671, HD 384 and IEC 364)
Accuracy (at 20° C) <2.5% of scale length (or 30% of reading 200 k½ to 10 M½)
Continuity ranges
Measuring Range 0,01 ½ - 99,9 ½ (0 -50 ½ on analogue scale)
Open Circuit Voltage 5 V ±1 V
Short Circuit Current 200 - 215 mA
200 - 250 mA
Terminal Characteristics
Accuracy (at 20° C) ±2.5% of scale length (or 30% of reading 0.2 ½ to 2 k½)
Zero Offset Adjust 0 - 9 ½
0 - 0.5 ½
Continuity Buzzer Operates at < 5
Response time <100 mS
Resistance range
Measuring Range 0 - 2k½ (refer to continuity)
Voltage range
Measuring Range 0 - 600 V a.c. (50/60 Hz) or d.c.
Accuracy (at 20° C) ±2.5% of scale length for 50/60Hz
Temperature coefficient <0,1% per °C on all ranges.
Default voltmeter
All modes including off
Test inhibit If more than 50 volts is detected, testing will be inhibited.
Temperature and humidity
Operating Range -10°C to +60°C
Operating Humidity 93% R.H. at +40°C max.:
Storage Range -25°C to +70°C
Test Result Storage (1000 results)
Job Number 255 locations
Distribution Board no. 99 locations
Circuits 99 locations
Phases P1, P2, P3
Last recorded result may be recalled to the display.
All data can be downloaded to a PC using Download Manager (supplied) or Megger Powersuite Professional of Windows software
Communications USB interface
Environmental Protection IP54
Fuses Terminals 500 mA (F) 600 V, 32 x 6 mm Ceramic HBC 10 kA minimum.
Display shows if fuse is ruptured.
Safety Meets the requirements of IEC61010-1 Cat III 600 V phase to earth.
Automatic discharge After an insulation test the item under test will be discharged automatically. Any voltage present will be indicated on the display so that the discharge can be monitored.
Power supply
Battery 8 x 1,5 V cells IEC LR6 type(AA alkaline).
Rechargeable NiCd or NiMH cells may be used.
Battery condition is constantly shown on the display as a four-section bargraph.
Battery Life 5000 consecutive tests (5 seconds per test) on any test using 2Ah batteries. Weight
All units 980 gms
Dimensions All units: 203 x 148 x 78 mm (8 x 5.7 x 3.2 inches)
E.M.C. In accordance with IEC61326 including amendment No.1



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET