Megger M8035 Dual Display Digital Multimeter
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   



Megger M8035 Dual Display Digital Multimeter




Click image to enlarge

Megger M8035

Data Sheet

Features:
  • Basic Accuracy from 0.08%
  • 4,000 & 40,000 Count
  • Dual Display
  • Analog Bargraph Updates 128 times every second
  • True r.m.s d.c. + a.c. and Average Responding
Included Accessories:
  • 1 - EV6121-355 - Rubber Holster
  • 1 - 1482-1 - 9 V Battery
  • 1 - Test Lead Set
  • 1 - Instruction Manual



  Description

The Megger M7000/M8000 Series of advanced analog/digital multimeters use the latest microprocessor technology to provide the most comprehensive measuring ranges and features in a hand held instrument.

There are four instruments in the range, the two M7000 models are for more general applications yet still incorporate many advanced features, whereas the M8000 models have been designed to provide greater accuracy with extensive additional measuring capabilities.

The M7000 units offer rugged dependability for use in field conditions. Both the M7027 and M7029 are supplied in rugged yellow cases with wrap around rubberised holsters for added protection against mishandling. The main difference between the models is that the M7027 has a basic accuracy of 0.3% and the M7029 has a basic accuracy of 0.2%. Both models have dual displays and the choice of operation in the 4,000 count or the higher resolution 40,000 count mode.

The M8000 models provide more advance features for applications requiring more extensive measuring capabilities. The M8037 is the top of the range instrument it measures true rms, a.c. + d.c. and a.c. voltage ranges, which more accurately measure voltage values regardless of the waveforms. Square, sawtooth, triangle, pulse trains, spikes as well as distorted waveforms with the presence of harmonics can all be measured accurately.

There are three different relative modes to choose from; Relative Zero, Relative Percentage and Relative per Unit. In Relative Zero mode the user is allowed to offset the meter measurements with a relative reference value, therefore subtracting this reference from any further measurement. In Relative Percentage change mode the bar graph automatically indicates ±200% or ±20% for full scale changes with respect to the Relative Reference value which becomes centre zero point. This simplifies zero, peaking, nulling measurements and is excellent for fine adjustments. The final relative range is Relative per Unit which shows the ratio of measuring values to the relative base value. For example measuring the parallel capacitance of co-axial cable or parallel wire in conjunction with the Relative per Unit mode, helps estimate the total cable length or pinpoint cable breakdown locations.




  Models, Options, & Accessories


Model Description List Price Sale Price
M8035 Dual Display Multimeter; 0.08% Accuracy
$299.00 
M7027 Dual Display Multimeter; 0.3% Accuracy
$210.00 
M7029 Dual Display Multimeter; 0.2% Accuracy
$245.00 
M8037 Dual Display True RMS Multimeter; 0.08 % Accuracy
$360.00 
Model Accessories List Price Sale Price
1482-1 9 V Battery
$6.00 
EV6121-355 Protective Holster
$52.00 
EV6111-218 FPK8 Fused Test Leads
$130.00 
EV6220-562 Lead Set with Crocodile Clip
$125.00 



  Specifications

Technical  
AC Conversion Type: Average Responding
Crest / Peak: 0.8 ms response, Max, Min
Max-Min
Sort: Auto-ranging Max, Min
Input Warning: Audible & Visible
Total Functions: 55 Ranges
DCV  
DCV: 40 mV to 1 kV in 6 ranges
Best Resolution: 1 µV
Basic Accuracy: ±0.08% ± 1 digit (0.5% ±6 digits on 40.00 mV)
NMRR @ 50/60 Hz: > 60 dB
CMRR @ DC: > 120 dB @ DC & 50/60 Hz
ACV  
ACV: 400 mV to 750 V in 5 ranges
Best Resolution: 10 µV
Basic Accuracy: ±0.5% ±3 digits 50-60 Hz
Basic Bandwidth: 40 Hz - 20 kHz
CMRR @ DC, 50/60 Hz: > 60 dB
DCA / ACA  
DCA / ACA: 400 µA to 10 A in 6 ranges
Best Resolution: 0.01 µA
Basic Accuracy: from ±0.2% ±2 digits to 1% ±4 digits
Resistance  
Resistance: 40 to 40 M-ohm in 7 ranges
Best Resolution: 0.001 ohm
Basic Accuracy: < 400 k-ohm ±0.15% ±2 dig., 40 M-ohm 1.5% ±5 dig.
Conductance  
Conductance: 400 nS in 1 range
Best Resolution: 0.1 nS
Basic Accuracy: ±0.7% ±5 digits
Capacitance  
Capacitance: 4 nF to 40 mF in 8 ranges
Best Resolution: 1 pF
Basic Accuracy: 40 nF - 4 µF: 0.8% ±5 dig. < 40 nF, > 4 µF ±4%
Frequency  
Frequency: 100 Hz to 4 mHz in 6 ranges
Best Resolution: 0.001 Hz
Basic Accuracy: ±0.002% ±3 digits


   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET