Martel Electronics M2000/M2001 Lab standard Multi-Function calibrators
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   




Martel Electronics M2000/M2001 Lab standard Multi-Function calibrators



Martel M2000A
Click image to enlarge

 Martel M2000A

Features:
  • Superior Calibration accuracy to 0.0025% of reading
  • Direct keyboard entry or cursor entry with decade control
  • Automatic standby function protects device under test
  • Source current, voltage, T/C, RTD (Ohms)
  • Read T/C, RTD and pressure
  • Source/read eleven (11) thermocouple types
  • Source/read nine (9) standard RTD types
  • Custom RTD/SPRT profile
  • Nine (9) setpoints for each output range and type
  • Local or RS232 remote control
  • Optional IEEE-488 control available
  • Compatible with Fluke Met/Cal® software
  • Optional rack/panel mount kit available
Additional Photos
Click image to enlarge




  Description

The Lab Calibrator combines the power and features of a voltage/current calibrator, with the addition of thermocouple, RTD, and pressure calibration, for a single laboratory calibration instrument unmatched in versatility, performance, and value. As with every Martel lab calibrator, the calibration equipment's world-class performance and features are accessed through a very simple-to-use, intuitive user interface. The calibration test equipment is truly a "process calibration laboratory in a box."




  Models, Options, & Accessories


Model Description List Price Sale Price
M2000A High Accuacy V/I Lab Standard with IEEE-488 Communication 120= 1919092, $1995.00
$1875.30 
M2000A High Accuacy V/I Lab Standard with IEEE-488 Communication 120= 1919092, $1995.00
$1875.30 
M2000A-120 M2000A [120] High Accuacy V/I Lab Standard with IEEE-488 Communication Interface $1995.00
$1875.30 
M2000A-240 M2000A [240] High Accuacy V/I Lab Standard with IEEE-488 Communication Interface $1995.00
$1875.30 
M2001 High accuracy process lab standard 120= 1919038, 240= 1919139 $3295.00
$3097.30 
M2001A M2001A High Accuracy Process Lab Standard with IEEE-488 Communication Interface $3595.00
$3379.30 
M2001A-120 M2001A [120] High Accuracy Process Lab Standard with IEEE-488 Communication Interface $3595.00
$3379.30 
M2001A-240 M2001A [240] High Accuracy Process Lab Standard with IEEE-488 Communication Interface $3595.00
$3379.30 



  Specifications

Specifications for M2000(1 year at 23°C ±5°C unless otherwise noted))
Output Voltage
Range 0 to 100.000 mV
0 to 1.00000 V
0 to 10.0000 V
0 to 100.000 V
Resolution
0 to 100 mV Range 1 µV
0 to 1 V Range :10 µV
0 to 10 V Range: 100 µV
0 to 100 V Range :1 mV
Accuracy (% of reading)
0 to 100 mV Range ±0.003% (30ppm) ± 3.0 µV
0 to 1 V Range :±0.003% (30ppm) ± 20.0 µV
0 to 10 V Range :±0.003% (30ppm) ± 200.0 µV
0 to 100 V Range ±0.003% (30ppm) ± 2.0 mV
Maximum Burden (≤ 1 Ohm output impedance)
0 to 100 mV Range 10 mA
0 to 1 V Range 10 mA
0 to 10 V Range 10 mA
0 to 100 V Range 1 mA
Output Current
Range 0 to 100.000 mA
Resolution 1 µA
Accuracy (% of reading) ±0.01% ± 2 µA
Maximum Burden 10 V
Stability
Warm-up Time 30 minutes to rated accuracy
Temp Co. (≤18°C/>28°C) 10% of accuracy spec/°C
Temperature Range
Operating 0°C to +50°C
Storage -20°C to +70°C
Power Requirements
Voltage range 90 to 240 VAC
<15 VA
Mechanical
Dimensions 11.5” x 4.7” x 8.75”(29.21 cm x 11.93 cm x 22.00cm)
Weight Approximately 5 pounds (2.27 kg)
Display 16 x 2 large character alphanumeric, backlit LCD



Specifications for M2001(1 year at 23°C ±5°C; % of reading, unless otherwise noted)
Output Voltage
Range 0 to 100.000 mV
0 to 1.00000 V
0 to 10.0000 V
0 to 100.000 V
Resolution
0 to 100 mV Range 1 µV
0 to 1 V Range 10 µV
0 to 10 V Range 100 µV
0 to 100 V Range 1 mV
Accuracy (% of reading)
0 to 100 mV Range ±0.003% (30ppm) ± 3 µV
0 to 1 V Range ±0.003% (30ppm) ± 20 µV
0 to 10 V Range ±0.003% (30ppm) ± 200 µV
0 to 100 V Range ±0.003% (30ppm) ± 2 mV
Maximum Burden (= 1 Ohm output impedance)
0 to 100 mV Range 10 mA
0 to 1 V Range 10 mA
0 to 10 V Range 10 mA
0 to 100 V Range 1 mA
Output Current
Range 0 to 100.000 mA
Resolution 1 µA
Accuracy (% of reading) ±0.01% ± 2 Counts
Maximum Burden 10 V
Thermocouples
Output
Types J, K, T, E, R, S, N, B, L, U, C
Range mV
Resolution 0.1 °C/°F
Accuracy 0.14 °C; Type J, typical
Input
Types J, K, T, E, R, S, N, B, L, U, C
Range mV
Resolution 0.01 °C/°F
Accuracy 0.14 °C; Type J, typical
RTD
Output
Range PT385 (100, 200, 500, 1000),PT392, PT3916 (JIS), Ni120, Cu10, YSI400
Resolution 0.1 °C/°F; PT385-100, typical
Accuracy ±0.1 °C; PT385-100, typical
Input (All ?/RTD inputs are 4 wire)
Range PT385 (100, 200, 500, 1000),PT392,PT3916 (JIS), Ni120,Cu10,YSI400, 25 Ohm SPRT
Resolution 0.001 °C/°F; PT385-100, typical
Accuracy ±0.020 °C; PT385-100, typical
Ohms
Output
Range 5 to 4000.0 Ohms
Resolution
5 to 400.00 0.01
5 to 4000.0 0.1
Accuracy
5 to 400.00 ±0.03
5 to 4000.0? ±0.3?
Input
Range 0 to 4000.00 Ohms
Resolution
0 to 400.00 0.001
0 to 4000.0 0.01
Accuracy
0 to 400.00 40 PPM ±0.002?
0 to 4000.0 40 PPM ±0.02?
Pressure
Range 0 to 1 inch H2O; to 10,000 psi
Compatibility All Fluke 700 Series Pressure Modules
Stability
Warm-up Time 30 minutes to rated accuracy
Temp Co. (=18°C/>28°C) 10% of accuracy spec/°C
Environmental
Operating Temperature 0°C to +50°C
Storage Temperature -20°C to +70°C
Humidity
Operating <80% to 30°C
<70% to 40°C
<40% to 50°C
Storage <95%, non-condensing
Power Requirements
VoltageRange 90 to 240 VAC
<15 VA
Mechanical
Dimensions 11.5" x 4.7" x 8.75"(29.21 cm x 11.93 cm x22.00cm)
Weight Approximately 5 pounds(2.27 kg)
Display 16 x 2 large character alphanumeric, backlit LCD



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET