Link Instruments DSO-8502 500 MSa/s PC Based Digital Storage Oscilloscope
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   



Link Instruments DSO-8502 500 MSa/s PC Based Digital Storage Oscilloscope




Click image to enlarge

 Link DSO-8502



The DSO-8502 is our newest series of USB 2.0 PC Based Oscilloscope. The DSO-8502 Oscilloscope operates at up to 500 MSa/s. Other features include a Spectrum Analyzer (FFT), Pulse width and count triggering, Channel History buffers, Pass/Fail testing and many measurements

Features:
  • High speed sampling
  • Large data buffer
  • USB 2.0 communications
  • History plots
  • Advanced Triggering
  • Auto-setup Of Capture & Channel Parametersv
  • 250 MHz Spectrum Analyzer/FFT
  • XY Plot
  • Customized Displays
  • Fast, Accurate Measurements
  • Easy Installation
  • Simple Operation
  • Automatic Data Storage
  • Battery Power
  • FrontPanelTM Oscilloscope software supports Windows
  • Print Support
  • Software Libraries (optional)



  Description

High Speed Sampling

The OScope captures single-shot data at 500MSa/s (every 2ns) 500MSa/S single shot sample rate on 1 channel with a 1 Million point buffer. 250MSa/S single shot sample rate on 2 channels with a 512K point buffer.

Advanced Triggering DSO

The DSO-8502 has advanced pulse triggering as well as standard level triggering.

Level Trigger
Level trigger with rising or falling slope
Multi Trigger
Trigger on multiple channels:
Pulse Width Trigger
Pulse width. Trigger on a pulse of a certain width
Pulse Count Trigger
Pulse count. Trigger on the Nth pulse

The oscilloscope has fully adjustable pre/post trigger position. This lets you define how much data is collected before the trigger event and how much is collected after.

Deep Acquisition Memory

1 Million point buffer on 1 channel at a sample rate of 500MSa/S. 512K point buffer on 2 channels at sample rates of 250MSa/S and below.

This is much longer than standard Oscilloscopes and enables you to capture more waveform details without sacrificing overall recording time. Longer data buffers give you the flexibility to use faster sample rates and still capture for extended periods of time.

“The big buffer really saved me. With my last oscilloscope I always had to balance recording time and time per division. With Link’s scope I can record at the fast sampling rate and still see the entire event.” Bob Mitchell, consultant. (beta tester)”

The Windows Oscilloscope software takes advantage of your computer's large color screen.

"zoom-and-scroll" simplifies trouble shooting and analysis. The display shows the entire recorded waveform(s). In addition, the user can zoom (up to 50X) on signal details and scroll through long data records to identify and characterize problems. The locked all-channel zoom keeps all the analog waveforms synchronized. The deep memory allows analysis of jitter from the beginning of the record to the end. By zooming/scrolling and then measuring with cursors, pulse widths and channel-to-channel timing can be compared at different sections of data streams. This feature allows identification of time varying problems such as "power-on" sequences and clock jitter.

Channel History - Similar to Persistence mode, but much better.

The Oscilloscope software can automatically save and display previous captures.

  • Each capture will be color coded based on time of trigger with the oldest ones fading to white.
  • Up to 27 captures can be displayed simultaneously.
  • Previous captures can be displayed by themselves, used with FFT, XY plot and Measurements.

Auto-Setup

With one mouse click the software will analyze incoming data and setup the oscilloscope using advanced data analysis routines. You can then fine tune any or all Scope parameters to your liking.

Spectrum Analyzer/FFT

  • The DSO also delivers high accuracy spectrum analysis. A binary FFT algorithm is used to break the input signal into its frequency components
  • Unlike swept spectrum analyzers which require a stable repetitive signal, the DSO-8000 can also analyze a single shot event
  • You can control and view both the FFT (frequency-domain) and oscilloscope (time-domain) display windows simultaneously
  • Two FFT channels can be viewed simultaneously.

  • Spectrum analyzer frequency range, FFT algorithm, spectral resolution and vertical/horizontal size can be set via the software. This flexibility helps to optimize the spectrum analyzer for a particular application. The frequency range extends from DC to 250MHz (Max frequency varies with model and mode)
  • FFT screen has its own set of cursors for magnitude and frequency readouts
  • FFT data can be saved to disk and exported to other programs such as Excel, Mathcad, etc...
  • Screen shots can be pasted into your documents

X-Y Oscilloscope plot


An X-Y Plot allows you to graph one channel vs. another.

Customizable Color Display

You can display any combination of Digital Oscilloscope and Spectrum Analyzer traces simultaneously.

Color can be a real time saver. Each display element can be a unique color. This includes each of the Data channels, Memories, Waveform functions, Horizontal cursors, Vertical cursors, Trigger position, Text, Background, Grid and more. We even color code the cursor measurements to the appropriate channel color.

Stand-alone oscilloscope display screens represent a compromise at best. Few people would choose a 7" or 9" monitor as the screen for their PC. So why use a small monitor for an oscilloscope? Link PC Based instruments let you choose the display monitor size and type for viewing your data. Plus, you can utilize powerful PC-industry display peripherals such as projectors, remote monitors, and heads-up displays. Many people are now using dual monitor PC's - our software will work there also - Imagine having a 30" wide trace window.

You can take electronic snapshots of the screen and put them into your documents as well as print data to your standard windows printer.

Fast, Accurate Measurements

  • Powerful cursors display voltage and time information
  • Advanced waveform measurements are included with the FrontPanelTM software
  • PASS/FAIL testing based on the results of those measurements is also available. Data can be logged to disk automatically on PASS or FAIL

Waveform Measurements

  • area
  • cursor A (time)
  • cursor A (voltage)
  • cursor B (time)
  • cursor B (voltage)
  • trigger cursor
  • cursor A - B (time)
  • cursor A - B (voltage)
  • cursor A - trigger (time)
  • cursor B - trigger (time)
  • cycles
  • cycles (user defined)
  • delay
  • delay (user defined)
  • delta delay
  • delta delay (user defined)
  • dutycycle (rising)
  • dutycycle (falling)
  • dutycycle (rising, user defined)
  • dutycycle (falling, user defined)
  • fall time (10..90)
  • fall time (20..80)
  • fall time (user defined)
  • fall time (A level to B level)
  • frequency
  • maximum
  • mean/median
  • minimum
  • peak to peak
  • period
  • pulse width (positive)
  • pulse width (negative)
  • pulse width (positive, user defined)
  • pulse width (negative, user defined)
  • rise time (10..90)
  • rise time (20..80)
  • rise time (user defined)
  • rise time (A level to B level)
  • rms voltage
  • rms voltage (AC)

Easy Installation

The PC Based oscilloscope connects to the USB port of your computer. To install the oscilloscope all you need to do is plug it into your PC, plug in the power supply and install the software.

The DSO is about the size of a video tape (7" x 3.75" x 1.5"). If you need portability what could be easier than connecting the DSO to your laptop?

Simple Operation

  • Installation is a snap
  • Make measurements in your first half hour
  • Simple controls make operation intuitive
  • All functions from one simple software "panel"
  • Perform sophisticated operations that you couldn't even dream of doing with a knob based DSO
  • Save default setups to disk for easy recall at a future date. You don't need to keep a notepad with settings scribbled in it. Just save them to the file name of your choice
  • Data and settings are easily saved to disk - no extra software to buy - no communications upgrades
  • Screen shots can be pasted into documents and annotated in your favorite image editing software

DSO's compared

  DSO-8502 DSO-2102M DSO-2102S
Max sample rate 500MSa/s 100MSa/s 100MSa/s
Memory size / Channels 1024K (1 channel)
512K (2 channels)
32K (2 channels) 32K (2 channels)
Connectivity USB 2.0 Parallel port
USB 1.1(with adapter)
Parallel port
USB 1.1(with adapter)
FFT 2 channels 1 channel 1 channel
Pass fail testing Yes Yes No
Datalogging Yes Yes No
Channel History Yes No No
Power source Wall or battery Wall or
Battery (optional)
Wall or
Battery (optional)

Battery power or wall power

Wall power
Most people will power their DSO-8000 series Oscilloscopes with the included wall adapter

Battery power
We have added a battery holder into the case that holds 4 AA batteries. Using AA batteries allows you to use the DSO away from a power source without draining your laptop's battery.

Automatic Data Storage

Superior to most stand-alone instruments, the DSO-8502 allows you to store an unlimited number of waveforms, timing patterns, and spectra to disk. Later, recall the data to the screen for visual inspection and comparison to "live" data, process the stored waveforms through our spectrum analyzer and waveform analysis functions, or use your own software to analyze archived waveforms.

To save time, you can automatically datalog your waveforms to your PC after each trigger. The data logger can also store only waveforms meeting specific parameter criteria, such as rise times between 20 and 30ns and pulse widths greater than 100ms, etc.... Data can be stored in our format or in industry standard format for exporting to other software.

FrontPanelTM Oscilloscope software supports Windows

OS's supported: USB 2.0
(compatible with USB 1.1)
Windows Vista
(Tested with Beta version of Vista)
Windows XP
Windows 2000

The DSO-8502 has software for Win XP, Win 2000 and has passed initial testing with Windows Vista. The oscilloscopes are PC Based and we regularly upgrade the software with more features and support for new operating systems. Software updates are free and available on the website.

Print Support

Waveforms can be printed on any Windows compatible printer.

Oscilloscope Probes

Two 1x/10x switchable probes are included with the oscilloscope.

We also sell the following types of probes:

  • 1x/10x (2 meter cable)
  • 100x
  • Differential Probes

The speed of your PC does not significantly affect the performance of our instruments

Although we rely on the PC to display the data and for the user interface. We don't rely on it for our high speed data acquisition. If your PC is fast enough and has enough memory to run windows well it will run our products well also. All of the high speed data acquisition is done in DSO.

The Instrument has high speed samplers and data buffers. It can acquire data at up to 500MSa/s*1 and stores the data in it's own 1 MegaSample*1 data buffer. When these buffers are full the data is transferred to the PC.

Software Libraries (optional)

The DSO-8000 series comes with FrontPanel for Win XP and Win 2K. We have done preliminary testing with Windows Vista beta versions and plan on supporting it when it is released.

But if you want to write your own software to drive the unit, our optional DLL or LabView drivers are available for purchase.

  • DLL and LabView VI Library
    DSO-8000-DLL-XP

PC Based Oscilloscopes are controlled with easy to use Windows software. This allows for more organized data display (with color coded data and increased screen size), intuitive user interface, and data management (file saving, loading, sharing and exporting to other software and reports). They are compact and don't have screens, drives, knobs or buttons - saving you money and space.




  Models, Options, & Accessories


Model Description List Price Sale Price
DSO-8502 Digital Storage Oscilloscope (2 channel) & Spectrum Analyzer. Comes with 115V 60Hz power supply. $950.00
$912.00 
Model Accessories List Price Sale Price
DSO-8000-UNIV-PWR International power supply. Universal (90v..264v, 50/60Hz) regulated power supply for customers not using United States voltages. Uses standard computer style cable. $38.00
$36.48 
DSO-8000-DLL-2K 32 bit version for Win 2K/XP only. For Visual C++ and LabView. The DLL library is only available for the DSO-8502 $300.00
$288.00 
DSO-PROBE-DIF-KIT Differential Probe( 10x/100x) for Digital Oscilloscope (Probe, power supply, case, assorted clips) $395.00
$379.20 
DSO-PROBE-X100 Probe( 100x) for Digital Oscilloscope (100MHz, 2 meter) $72.00
$69.12 
DSO-PROBE-2M Probe( 1x/10x) for Digital Oscilloscope (100MHz, 2 meter) $60.00
$57.60 
DSO-P100 Probe( 1x/10x) for Digital Oscilloscope (100MHz, 1 meter) $45.00
$43.20 



  Specifications

Input
Max Sample Rate 500MSa/s on 1 channel
250MSa/s on 2 channels
Bandwidth 100MHz
Channels 2 + External trigger
Max Input Voltage
(at BNC connector)
max input voltage at probe tip depends on probe type (1x, 10x, 100x, etc.)
Probe Continuous Transient (DC + AC <10KHz)
BNC ± 50V DC ± 150V DC
1X probe: ± 50V DC ± 150V DC
10X probe: ± 500V DC ± 1,500V DC
100X probe: ± 5,000V DC ± 15,000V DC
1000X probe: ± 50,000V DC ± 150,000V DC
Gain Range (per division)
full scale = 10 divisions
Probe Voltage per division Full scale voltage
1x probe: 5mV to 5V per division 50mV to 50V (full scale)
10x probe: 50mV to 50V per division 500mV to 500V (full scale)
100x probe: 500mV to 500V per division 5V to 5000V (full scale)
1000x probe: 5V to 5,000V per division 50V to 50,000V (full scale)
Vertical Resolution 8 bits/channel
Vertical Range 10 divisions
External Trigger TTL level (1.4V trigger) Max voltage: 5V
Offset Range ± 5 divisions
Coupling AC, DC, and Ground
Offset Resolution 0.04 division increments
Impedance 1MΩ // 15pF
DC Accuracy ± 2%
A/D Dual 8 bit
Probes 1x/10x switchable with standard BNC connector. Two probes are included.
100x probes are available as an option (see below)
Timebase
Rate 500MSa/s... 5Sa/s
2ns/sample to 5s/sample
2ns/division to 20secons/division
Accuracy +/- 0.01%
Resolution 10ns
Channel Skew < 1ns
Memory
Buffer Size 1 Million points/channel (1 channel mode)
512K points/channel (2 channel mode)
Calibration
Oscilloscope Self calibrating
Probe Calibration signal provided
Trigger
Type Rising Edge (Adjustable level),
Falling Edge (Adjustable level),
TV-H,
TV-V,
Pulse Width,
Pulse Count,
Pulse Width & Pulse Count
External Trigger In Yes
External Trigger Out Yes
Trigger On Rising Edge Yes
Trigger On Falling Edge Yes
Trigger On Pulse Count Yes
Trigger On Pulse Width Yes
Trigger On Pulse Width & Count Yes
TV Horizontal Trigger Yes
TV Vertical Trigger Yes
Trigger Out Yes
Mode Auto, Normal, and Single
Autosetup Yes
Slope Rising or Falling
Level Adjustable
Range (vertical) 10 divisions
Resolution 0.04 division increments
Software
Windows XP/2K Yes
FFT Yes
XY Plot Yes
Math Yes
Advanced Math Yes
Pass/Fail Testing Yes
Data Logging
(based on pass/fail test)
Yes
Data Logging
(on every capture)
Yes
Physical
Included DSO, probes, communications cable, power supply (USA), and software
(optional international power supply is also available)
Interface USB 2.0
Probes Two 1x/10x switchable probes are included.
BNC Connectors 4 total: 2 input, trigger in and trigger out
Calibration point Yes
Power Requirement 5V at 750mA (Typical)
Dimensions 7" x 3.75" x 1.5"



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET