| Frequency Range |
30 MHz to 950 MHz |
| Frequency Resolution |
50 kHz |
| Frequency Accuracy |
10 ppm |
| Frequency Switching Time |
Within 100 ms |
| Frequency Setting |
| Channel Mode |
Setting with a built-in channel table |
| Frequency Mode |
Setting an arbitrary frequency |
| Output Impedance |
75 Ω |
| Output Connector |
BNC |
| Output Level Range |
-80 to 0 dBm (0 dBm max.) |
| Level Resolution |
1 dB |
| Output Level Accuracy |
±2 dB (0 to -9 dBm) ±3 dB (-10 to -80 dBm) |
| Spurious |
Within -30 dBc (Harmonics) Within -40 dBc (Non-Harmonics) |
| Modulation System |
Amplitude modulation of the VSB (vestigial sideband) system according to a broadcast system |
| Modulation |
| At the time of built-in channel table setting |
87.5 %±3 % (Negative modulation) 97.0 %±3 % (Positive modulation) |
| At the time of arbitrary setting |
0 to 100 % (in 0.5 % steps) |
| Modulation Frequency Band |
|
| At the time of built-in channel table setting |
4.2 MHz/5.0 MHz/6.0 MHz (Depends on a broadcast system) |
| At the time of arbitrary setting |
4.2 MHz/5.0 MHz/6.0 MHz |
| Modulation Frequency Flatness |
±1 dB |
| Input Impedance |
75 Ω |
| Input Connector |
BNC |
| Reference Input Level |
1 Vp-p |
| Spectrum Polarity |
Positive (upper sound wave) |
| Built-in Pattern |
Full-field Color Bar (NTSC/PAL) Line sweep (at 100 % modulation: 4.2 MHz) (NTSC/PAL) |
| Carrier Frequency |
| At the time of built-in channel table setting |
4.5 MHz/5.5 MHz/6.0 MHz/6.5 MHz (Depends on a broadcast system) |
| At the time of arbitrary setting |
4.5 to 6.5 MHz (in 0.5 MHz steps) |
| Video Sound Ratio |
| At the time of built-in channel table setting |
-6 dB/-7 dB/-10 dB (Depends on a broadcast system) |
| At the time of arbitrary setting |
-30 to 0 dB (in 1 dB steps) |
| Modulation Types |
FM/AM (L System) (Depends on a broadcast system at the time of builtin channel table setting) |
| Frequency Deviation |
| At the time of a built-in channel table Setting |
15 kHz/30 kHz(equivalent to 60 % of the maximum deviation for each broadcasting system) |
| At the time of an arbitrary setting |
0 to 100 kHz (in 1 kHz steps) |
| Modulation (AM) |
| At the time of built-in channel table Setting |
60 % |
| At the time of arbitrary setting |
0 to 60 % (in 1 % steps) |
| Pre-Emphasis |
| At the time of built-in channel table setting |
75 µs/50 µs (Depends on a broadcast system) |
| At the time of arbitrary setting |
75 µs/50 µs/OFF |
| Modulation Frequency Response |
40 Hz to 100 kHz |
| Modulation Frequency Flatness |
±1 dB |
| Reference Input Level |
0 dBm (0.775 Vrms) |
| Input Impedance |
600 Ω |
| Input Connector |
BNC |
| Built-in Sound Signal |
Sine wave 400 Hz/1 kHz |
| Preset |
| Function |
Up to 100 sets of panel settings can be stored and recalled. |
| GPIB |
| Function |
Enables the key operations of the front panel except a power switch. |
| Connector |
24-pin rectangular connector 57LE-20240-7700D35G (DDK) or equivalent |
| Corresponding Standard |
ANSI/IEEE Std 488.1-1987 |
| REMOTE |
| Function |
Enables the INC, DEC, and RESET operations of the preset memory. |
| Connector |
14-pin rectangular connector 57LE-4014-7700 (DDK) or equivalent |
| Input Level |
TTL |
| RS232C |
| Function |
Controls the Video signal generator LT 450, Selects the INC, DEC, or RESET/video format which are related to the PRESET-MEMORY. |
| Connector |
9-pin D-Sub (M) |
| Signal Format |
Bidirectional serial data |
| Environmental Conditions |
| Operating Temperature |
0 to 40 °C |
| Operating Humidity |
<=85 %RH (without condensation) |
| Operating Environment |
Indoor use |
| Operating Altitude |
Up to 2,000 m |
| Overvoltage Category |
II |
| Pollution Degree |
2 |
| Power Requirements |
| Voltage |
AC90 to 250 V |
| Power Frequency |
50/60 Hz |
| Power Consumption |
35 W max. |
| Dimensions |
426(W) X 88(H) X 400(D) mm (excluding projections) |
| Weight |
5.6 kg |